Presentation is loading. Please wait.

Presentation is loading. Please wait.

Axel Drees, Stony Brook University BNL review of RHIC detector upgrades, March 14 th 2006 Overview of PHENIX upgrades Goals of PHENIX upgrades program.

Similar presentations


Presentation on theme: "Axel Drees, Stony Brook University BNL review of RHIC detector upgrades, March 14 th 2006 Overview of PHENIX upgrades Goals of PHENIX upgrades program."— Presentation transcript:

1 Axel Drees, Stony Brook University BNL review of RHIC detector upgrades, March 14 th 2006 Overview of PHENIX upgrades Goals of PHENIX upgrades program PHENIX upgrades at a glance detector systems and status physics reach of combined system new detector systems not covered today The FVTX and NCC proposals Submitted BNL to seek construction funds starting FY08 PHENIX internal review in December 2005

2 Axel Drees Physics Beyond the Reach of PHENIX High T QCD (AA, pA, and pp): Electromagnetic radiation (e + e  pair continuum) Heavy flavor (c- and b-production) Jet tomography (high p T PID, jet-jet and  -jet) Quarkonium (J/ ,  ’,  c and  (1s),  (2s),  (3s)) Spin structure of the nucleon: Gluon spin structure  G/G (heavy flavor and  -jet correlations) Quark spin structure  q/q (W-production) Low x phenomena gluon saturation in nuclei (particle production at forward rapidity) Provide key measurements so far inaccessible at RHIC in three broad areas: requires highest AA luminosity All measurements base on existing capabilities enhance by detector upgrades

3 Axel Drees Dalitz/conversion rejection (HBD) Precision vertex tracking (VTX) PID (k, ,p) to 10 GeV (Aerogel/TOF) High rate trigger (  trigger) Precision vertex tracking (FVTX) Electron and photon measurements Muon arm acceptance (NCC) Very forward (MPC) PHENIX Detector Upgrades at a Glance Central arms: Electron and Photon measurements Electromagnetic calorimeter Precision momentum determination Hadron identification Muon arms: Muon Identification Momentum determination

4 Axel Drees Dalitz/conversion rejection (HBD) Precision vertex tracking (VTX) PID (k, ,p) to 10 GeV (Aerogel/TOF) High rate trigger (  trigger) Precision vertex tracking (FVTX) Electron and photon measurements Muon arm acceptance (NCC) Very forward (MPC) PHENIX Detector Upgrades at a Glance Central arms: Electron and Photon measurements Electromagnetic calorimeter Precision momentum determination Hadron identification Muon arms: Muon Identification Momentum determination MPC south Preparing for HBD installation in April/May 2006 TOF west MRPC construction Installation 2006 Areogel completed 2005

5 Axel Drees HBD VTX NCC PHENIX Upgrades in Central Region Vertex Tracking (barrel and forward endcaps) Precision measurements of charm and bottom production Barrel (VTX) funded through RIKEN ($3M) and DOE ($4.6M), now in FY07 presidents budget Forward endcaps proposed to DOE (~$4.5M), reviewed today Hadron blind detector (HBD) Reject Dalitz/Conversion electrons in electron pair measurement Under construction funded through BNL, NSF, SBU, WI  trigger W measurements in pp ~$2M funded through NSF Nose Cone Calorimeter  0 and photon measurements Proposed to DOE (~$4M), reviewed today R3……...R2………..R1

6 Axel Drees PHENIX Upgrades Physics Capabilities X upgrade critical for success O upgrade significantly enhancements program PHENIX upgrades designed for optimum physics output with RHIC II luminosity

7 Axel Drees NCC MPC VTX & FVTX -3 -2 -1 0 1 2 3 rapidity  coverage 2  HBD EMCAL (i)  0 and direct  with combination of all electromagnetic calorimeters (ii) heavy flavor with precision vertex tracking with silicon detectors combine (i)&(ii) for jet tomography with  -jet (iii) low mass dilepton measurments with HBD + PHENIX central arms Future PHENIX Acceptance for Hard Probes

8 Axel Drees Integrated Design for PHENIX Vertex Spectrometer NCC VTX FVTX

9 Axel Drees Two Proposals Submitted to BNL for FY08 Construction Proposal readiness review by PHENIX DC/EC in December 2005 All recommendations addressed and incorporated to proposals

10 Axel Drees 2002200320042005200620072008200920102011 Aerogel TOF-W HBD VTX-barrel VTX-endcap NCC MuTrigger DAQ R&D PhaseConstruction Phase Ready for Data PHENIX Upgrades Schedule

11 Axel Drees Backup Slides

12 Axel Drees Upgrade Subsystem Detector typePhysics programCollaborating Institutions 12/2005 Hadron Blind Detector GEM-based CerenkovLow mass di- electrons BNL, Columbia U, U Mass, RBRC, Stony Brook U, U Tokyo, WIS Muon TriggerRes Plate ChambersQuark spin structure W-polarization ACU, Columbia U, ISU, Kyoto U, Peking U, RBRC, UCR, U Colorado, UIUC Silicon Vertex Barrel Silicon pixel + strips  +jet, heavy quark spec. jet tomography BNL, Ecole Polytech., FSU, ISU, KEK, Kyoto U, LANL, Niigata U, ORNL, RIKEN, Rikkyo U, Stony Brook U, UNM Forward Silicon Vertex Silicon mini-strips  +jet, heavy quark spec. jet tomography, CGC BNL, Charles U, Columbia U, Czech Tech U, Inst Phys Czech Acad Sci, ISU, LANL, NMSU, UNM Nose Cone Calorimeter Tungsten-silicon calorimeter  +jet, W- polarization heavy quark spectroscopy, jet tomography BNL, Charles Univ, Columbia U, Czech Tech U, EWU-Korea, Inst Phys Czech Acad Sci, ISU, JINR-Dubna, Korea U, Moscow State, RIKEN, Stony Brook U, Tsukuba U, UCR, UIUC, Yonsei U Data AcquisitionElectronics, computingHigh luminosity, high rate BNL, Columbia U, ISU

13 Axel Drees Ongoing HBD and Muon Trigger Upgrade Projects Muon trigger upgrade Funded through NSF ($1.9M) Installation in 2008 Univ. Illinois-UC, UC-Riverside, Iowa State Univ., Abilene Christian Univ., Univ. Colorado, Peking Univ., Columbia Univ., Kyoto Univ, RBRC, Georgia State Univ. R1 R2 R3 signal electron Cherenkov blobs partner positron needed for rejection e+e+ e-e-  pair opening angle HBD full scale prototype ~ 1 m Installation of full scale prototype next month Final detector under construction Funded through BNL, NSF, SBU, WI Weizmann Inst., Stony Brook Univ., BNL, Columbia Univ., Florida Inst. Tech., CNS-Tokyo, Univ. Mass, RIKEN BNL Res. Center (RBRC)

14 Axel Drees PHENIX Vertex Tracker Barrel (VTX) Joint RIKEN/DOE project 72 collaborators from 14 institutions BNL, Florida State Univ., Iowa State Univ., KEK, Kyoto Univ., LANL, Niigata Univ., ORNL, RIKEN, RIKEN BNL Reas. Center, Stony Brook Univ., Univ. New Mexico, Ecole Poly Tech, Saclay RIKEN contribution ($3M) Hybrid pixel detectors (developed at CERN for ALICE) under construction DOE contribution ($4.6M) Strip detectors, sensors developed at BNL with FNAL’s SVX4 readout chip funding proposed in FY07 presidents budget Readiness review in 2 months VTX barrel |  |<1.2 Pixel Detectors (50  m x 425  m) at R ~ 2.5 & 5 cm Strip Detectors (80  m x 3 cm) at R ~ 10 & 14 cm Prototype pixel ladder pilot