Presentation is loading. Please wait.

Presentation is loading. Please wait.

LM strategy Interventional cardiology dpt Cardiovascular Hospital - Lyon - France Gilles Rioufol MD PhD INSERM U1060 High Tech Marseille, 26 Janvier 2012.

Similar presentations


Presentation on theme: "LM strategy Interventional cardiology dpt Cardiovascular Hospital - Lyon - France Gilles Rioufol MD PhD INSERM U1060 High Tech Marseille, 26 Janvier 2012."— Presentation transcript:

1 LM strategy Interventional cardiology dpt Cardiovascular Hospital - Lyon - France Gilles Rioufol MD PhD INSERM U1060 High Tech Marseille, 26 Janvier 2012

2 ACS high risk Troponin + Unstable distal LM Rapid revascularization Thrombotic event Bifurcation management Type of stent Cx management stratification

3 Immediate or urgent revascularization? No pain Hemodynamic instability? Loading dose clopidogrel P2Y12 measurement 12h later Compliance evaluation Bleeding risk evaluation Patient’s choice Technical strategy Close watching – ICU

4 The angiogram showed a marked decrease in the thrombus burden. Thrombus management Bifurcation PCI = multiple balloons inflations = high embolization risk

5 Technical strategy Medina 1.0.0 ? Cx ostia Cx #3.5 mm diameter – 90° takeoff – ostium free/contralateral plaque Medina 1.1.0 ? LM diameter# 0.678*(3.5+3) # 4.5 mm ? Stent design allowing 1.5 mm step?

6 Soulis et al. J of Biomechanics 2006;39:742. Vessel dimensions 3 Main vessel Side branch 4.44 ± 0.84 mm 3.65 ± 0.77 mm 3.04 ± 0.58 mm ∆D = 0.79 ± 0.36 mm Range [0.23 - 1.42 mm] Murray CD. Proc. Natl Acad. Sci. USA, 1926 Finet G. et al. EuroIntervention 2007 Motreff P., Finet G. et al. Eurointervention 2009 D 0 3 = D 1 3 + D 2 3 Murray’s law D 0 = 0.678 x (D 1 + D 2 ) Linear law Unprotected LMCA IVUS-guided PCI 4.51 mm3.45 mm

7 Distribution of low shear stress and localization of atherosclerosis lesion Nakazawa et al. JACC 2010;55:1679 Plaque thickness (mm), n=36

8 LM PCI : type of stent? Park et al. Circ cardiovasc Interv 2009;2:167

9 Guidelines on myocardial revascularization ESC 2010

10 Stent underexpansion are related to stent thrombosis after SES implantation Fujii et al. JACC 2005 Procedural characteristics, angiographic and IVUS findings IntraVascularUltraSound help – EBM (I)

11 Propensy-matched paired-patients analysis Park et al. Circ cardiovasc Interv 2009;2:167 MAIN COMPARE registry DES (sirolimus) n=145 IntraVascularUltraSound help – EBM (II)

12 Guidelines on myocardial revascularization ESC 2010

13 Area (mm 2 ) 9,722,325,084,76 Diameter (mm) 3,531,752,572,49 LM PCI : why IVUS helps (I)

14 CIRCX LM LAD (1) Ref LM 16,2mm 2 (2) LM stenosis 4,9mm 2 (3)Ostial LAD 8,06mm 2 DES 16x3.5 – kissing 3.5/3.0 LM PCI : why IVUS helps (II)

15 CIRCX LAD LM MLA 9,8 mm2 malapposition DES 16x3.5 – kissing 3.5/3.0 CIRCX LADLM Postdilatation 4.5 mm

16 Conclusion Proposal strategy DES – IVUS guided length diameter apposition SB SB Provisional stenting Final kissing Thienopyridin response Compliance Technical feasability Thrombus management


Download ppt "LM strategy Interventional cardiology dpt Cardiovascular Hospital - Lyon - France Gilles Rioufol MD PhD INSERM U1060 High Tech Marseille, 26 Janvier 2012."

Similar presentations


Ads by Google