4th Annual Appalachian Basin Gas Well Deliquification Workshop Marietta College, Marietta, Ohio June 3 – 5, 2013 Mark Scantlebury, P. Eng., BASc President.

Similar presentations


Presentation on theme: "4th Annual Appalachian Basin Gas Well Deliquification Workshop Marietta College, Marietta, Ohio June 3 – 5, 2013 Mark Scantlebury, P. Eng., BASc President."— Presentation transcript:

1 4th Annual Appalachian Basin Gas Well Deliquification Workshop Marietta College, Marietta, Ohio June 3 – 5, 2013 Mark Scantlebury, P. Eng., BASc President and CEO Extreme Telematics Corp. Applications for Magnetic Sensing in Plunger Lift

2 Overview Background Problems With Plunger Arrival Sensors Solving The Problems Other Benefits Other Applications June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 2

3 Background Magnetic Sensing Has Been in Plunger Lift for Years –Mechanical movement of a magnet as plunger arrives –Coil Based Designs that Induce Current –Riddled with problems –One of the least expensive parts of the system can be the most critical –Leads to poor system performance to compensate for bad sensors June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 3

4 The Problems There are several problem with current designs –False Detections –Missed Arrivals –Noisy Switch Closure –Short Switch Closure –High Power Draw June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 4

5 The Problems Why Sensors Have False Detections –Poor Noise Immunity – Interference from other devices, electrical noise, or temperature fluctuations. –Designed with Too High of Sensitivity – Small movements seen as plunger arrival –Manufacturing Defects – Not all coils created equally. June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 5

6 The Problems June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 6

7 The Problems Missed Arrivals –Plunger travels too slowly past the sensor –Plunger does not travel all the way past the sensor –Sensitivity is not high enough –Non-ferrous or alloy plungers are invisible Venturi Viper™ (titanium) Viper™ (stainless steel) June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 7

8 The Problems Noisy Switch Closure –Accepted as the norm –Bouncing plungers –Inconsistent movement –System noise –Plunger geometry June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 8

9 The Problems Short Switch Closure –Short Plungers –Fast Plungers –Output not active long enough –Missed using polling architecture June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 9

10 The Problems High Power Draw –Fast moving plungers cause high current –Large current consumption while switch is closed –Would prefer a more consistent power draw June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 10

11 The Solution A microprocessor based design that implements a magnetic field sensor. –Noise Immunity –Enhanced Detection Algorithms –Adjustable Sensitivity –Flexible Mounting Location –More Repeatability/Reliability –Upgradable Software –Real Time Debugging June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 11

12 The Solution Noise Immunity –Can’t prevent all noise –Filter it out using a long term average June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 12

13 The Solution Detection –Continuously monitor the changes in the signal –Low amplitude or short duration changes ignored –Eliminates false detections June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 13

14 The Solution Enhanced Detection Algorithms –Determine a long term average/baseline –Look for patterns –Distinguish between slow or rapid change –Adjust for different plunger types June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 14

15 The Solution Adjustable Sensitivity –Use a switch or some other input device –Changed by operator/installer at any time –Sets a threshold for detection of different plunger types –Allows balance between false detects and missed arrivals June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 15

16 The Solution Flexible Mounting Location –Plunger does not need to pass by sensor –Not dependent on speed –Sense through thicker lubricators –Mount on flow tee, master valve, or casing –Sense movement of other lubricator parts when using non-ferrous plungers June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 16

17 The Solution Repeatability/Reliability –Easier to manufacture –Better tolerances –No moving parts to wear –Factory calibration –Self calibrating –Large spread between thresholds –Self test June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 17

18 The Solution Upgradable Software –Embedded firmware –New images loaded on demand –Feedback from the field June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 18

19 The Solution Real Time Debugging –Not limited to a switch interface –Real time stream data –Graph in real time –Log to file –Understand field data better –Identify problems or limitations –Truly an electronic “eye” on your well June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 19

20 Data Capture Tools June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 20

21 What’s Next Now that a new standard has been set, there are many more uses for this type of technology –Enhanced Detection Algorithms –Sensing Plunger Velocity June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 21

22 Enhanced Detection Algorithms Gather Data From the Field Solve Additional Problems –Interference from lightning –Interference from other systems –Different Plunger Types Continuous Improvement –100% detection is achievable June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 22

23 Plunger Data June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 23

24 Plunger Data June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 24

25 Plunger Data June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 25

26 Plunger Data June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 26

27 Fast Plungers Fast Plungers are the #1 problem in Plunger Lift Costly to Replace Cracked Lubricator Incident Reports, Injury, or Death Desire to Detect and Correct Fast Plungers Before They Cause Problems June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 27

28 Conventional Wisdom Why Not Use 2 Sensors? Too Reliant on Sensor Output –Different Sensitivity –Different Clocks Error in Position Need Additional Hardware Have to be Spaced out 10s -100s of meters to Reduce Error Not Practical June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 28

29 Magnetic Domain Look at the Magnetic Domain Instead of Switch Output More Information Available in Waveforms Not Simple to Detect Velocity Captured Data from Cyclops is Invaluable Thousands of Test Runs During Development Variations in Plunger Types, Velocity, Position June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 29

30 Sample Data June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 30

31 Sample Data June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 31

32 Sensing Plunger Velocity There are Some Challenges with these Waveforms –Different for Each Plunger Type –Variance in Sensitivity –Differences Due to Position There Does Appear to Be Hope –Deviation Correlated to Velocity –Enough Similarities to be Usable June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 32

33 Sensing Plunger Velocity ETC has Filed Patent Pending Algorithms for Detecting Plunger Velocity Use Combination of Deformation from Baseline, Waveform Timings, and Amplitude. Avoids Errors Associated with Using Multiple Independent Devices Well Head Mounted Velocity Sensor Practical Solution for Every Well June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 33

34 Sasquatch IS First Plunger Velocity Sensor Well Head Mounted Same Rugged Design as Cyclops IS Reliable Detection up to 750 m/min Discrete or Modbus Interface Will Help Prevent Lubricator Breaches Field Trial Summer 2013 June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 34

35 Other Applications Monitoring Earth’s Magnetic Field –Looking for a Change –Rotating Equipment –Sliding Metal –Movement in Relation to Earth Lots of Other Applications Possibilities are Endless June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 35

36 Questions? June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 36

37 June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 37 Copyright Rights to this presentation are owned by the company(ies) and/or author(s) listed on the title page. By submitting this presentation to the Gas Well Deliquification Workshop, they grant to the Workshop, the Artificial Lift Research and Development Council (ALRDC), and the Southwestern Petroleum Short Course (SWPSC), rights to: –Display the presentation at the Workshop. –Place it on the www.alrdc.com web site, with access to the site to be as directed by the Workshop Steering Committee. –Place it on a CD for distribution and/or sale as directed by the Workshop Steering Committee. Other use of this presentation is prohibited without the expressed written permission of the author(s). The owner company(ies) and/or author(s) may publish this material in other journals or magazines if they refer to the Gas Well Deliquification Workshop where it was first presented.

38 June 3 – 5, 2013 2013 Appalachian Basin Gas Well Deliquification Workshop, Marietta, Ohio 38 Disclaimer The following disclaimer shall be included as the last page of a Technical Presentation or Continuing Education Course. A similar disclaimer is included on the front page of the Gas Well Deliquification Web Site. The Artificial Lift Research and Development Council and its officers and trustees, and the Gas Well Deliquification Workshop Steering Committee members, and their supporting organizations and companies (here-in-after referred to as the Sponsoring Organizations), and the author(s) of this Technical Presentation or Continuing Education Training Course and their company(ies), provide this presentation and/or training material at the Gas Well Deliquification Workshop "as is" without any warranty of any kind, express or implied, as to the accuracy of the information or the products or services referred to by any presenter (in so far as such warranties may be excluded under any relevant law) and these members and their companies will not be liable for unlawful actions and any losses or damage that may result from use of any presentation as a consequence of any inaccuracies in, or any omission from, the information which therein may be contained. The views, opinions, and conclusions expressed in these presentations and/or training materials are those of the author and not necessarily those of the Sponsoring Organizations. The author is solely responsible for the content of the materials. The Sponsoring Organizations cannot and do not warrant the accuracy of these documents beyond the source documents, although we do make every attempt to work from authoritative sources. The Sponsoring Organizations provide these presentations and/or training materials as a service. The Sponsoring Organizations make no representations or warranties, express or implied, with respect to the presentations and/or training materials, or any part thereof, including any warrantees of title, non-infringement of copyright or patent rights of others, merchantability, or fitness or suitability for any purpose.


Download ppt "4th Annual Appalachian Basin Gas Well Deliquification Workshop Marietta College, Marietta, Ohio June 3 – 5, 2013 Mark Scantlebury, P. Eng., BASc President."