Presentation is loading. Please wait.

Presentation is loading. Please wait.

Collab 4/15/04 #1 EDMEDM UIUC meeting 12/3/2004 Walter Sondheim, P-25, Los Alamos for presentation to The EDM Collaboration UIUC meeting, Urbana, IL UCN.

Similar presentations


Presentation on theme: "Collab 4/15/04 #1 EDMEDM UIUC meeting 12/3/2004 Walter Sondheim, P-25, Los Alamos for presentation to The EDM Collaboration UIUC meeting, Urbana, IL UCN."— Presentation transcript:

1 Collab 4/15/04 #1 EDMEDM UIUC meeting 12/3/2004 Walter Sondheim, P-25, Los Alamos for presentation to The EDM Collaboration UIUC meeting, Urbana, IL UCN storage/lifetime tests run at LANSCE

2 Collab 4/15/04 #2 EDMEDM UCN lifetime measurement Current status of EDM beamline: EDM gate valve, released to shop for fabrication. EDM/UCN switcher, release to shop for fabrication (2) EDM test chamber, moved into Area-B, lid removed for inspection. A Helitran pump has been identified for cooling acrylic trap. A Cryotorr pump and gate valve are available to connect to the test chamber, along with a scroll pump. All other beamline components are in the “design” stage.

3 Collab 4/15/04 #3 EDMEDM View of UCN experiment UCN beam height 108 in. from floor B4 shield block, 60in. H. x 32in. x 72in.

4 Collab 4/15/04 #4 EDMEDM Plan view of UCN experiment Pre-polarizer magnet AFP magnet SCS spectrometer magnet All three magnets shown Are superconducting

5 Collab 4/15/04 #5 EDMEDM EDM test chamber on UCN beamline Chamber is 40 in. dia. X 36 in. height, 4-32 in. flanges with 23.5in dia. ports. 8 in. dia. Acrylic Tube, with diamond coating, UCN trap UCN trap-door Direction of beam

6 Collab 4/15/04 #6 EDMEDM LANSCE, exp. Area-B, UCN source Experimental area-B is 78ft L x 60ft W x 23ft H Liquid Helium cryogenic facility UCN source UCN lifetime Test chamber

7 Collab 4/15/04 #7 EDMEDM EDM beamline components EDM switchEDM valve EDM switch-2, now a shutter 40 in

8 Collab 4/15/04 #8 EDMEDM ARS model 3B Heli-tran, open cycle cryo. system

9 Collab 4/15/04 #9 EDMEDM Cryo-Torr-8 Water vapor – 4,000 l/sec, Air – 1,500 l/sec, H2 – 2,500 l/sec

10 Collab 4/15/04 #10 EDMEDM Area – B at LANSCE

11 Collab 4/15/04 #11 EDMEDM Area – B at LANSCE

12 Collab 4/15/04 #12 EDMEDM UCN guide switch, exploded view

13 Collab 4/15/04 #13 EDMEDM UCN Gate Valve

14 Collab 4/15/04 #14 EDMEDM Area – B at LANSCE

15 Collab 4/15/04 #15 EDMEDM Tasks Needed.... There are a number of tasks needed in order to accept UCNs into the test chamber:. Locate operational Helitran. Finalize length of beam flight path, between test cell/trap and gate valve. Develop design for new simple switch – obtain a 6” Conflat cross. Quartz UCN beam guides with diamond coating. Scroll pump to evacuate test chamber and beamline. Electrical isolation from UCN beamline. Possible additional tasks yet to be defined.....


Download ppt "Collab 4/15/04 #1 EDMEDM UIUC meeting 12/3/2004 Walter Sondheim, P-25, Los Alamos for presentation to The EDM Collaboration UIUC meeting, Urbana, IL UCN."

Similar presentations


Ads by Google