Presentation is loading. Please wait.

Presentation is loading. Please wait.

Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.

Similar presentations


Presentation on theme: "Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP."— Presentation transcript:

1 Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP

2 What’s What 1. Face piece Connector 2. Clip 3. Inner Mask 4. Visor 5. Clamping Frame 6. Front Strap 7. Head Straps 8. Soft body 9. Face blank 10. Button March 26 2009 O2 TNG, MRT Trainee - POM 2

3 Use For masks with visor wiper: Soak the wiper with the de- misting agent. It must not be actuated when dry. Hold the full face mask ready: Undo the straps as far as possible. Put on the PSS BG 4 Closed-Circuit Breathing Apparatus, and press the plug-in connector until it engages March 26 2009 O2 TNG, MRT Trainee - POM 3

4 Use Put on the mask: Unbutton the strap and place chin in recess. Fit straps round the head and pull them back until the front strap rests smoothly on the face. Position the Mask 1. Tighten the neck straps uniformly 2. Tighten the temple straps uniformly 3. Tighten the front strap if head is fairly small. March 26 2009 O2 TNG, MRT Trainee - POM 4

5 Check for Leaks Tightly compress both breathing hoses and breathe in until vacuum is produced. Briefly hold your breath: the vacuum must be maintained. If it is not, the straps must be tightened further. The leak test must be repeated twice. The mask may only be used if perfectly tight! March 26 2009 O2 TNG, MRT Trainee - POM 5

6 Wiper If the visor mists over, it can be cleared by wiping. The wiper is activated via a lever on the outside of the visor. The wiper must then be returned to its basic position in the middle of the visor. March 26 2009 O2 TNG, MRT Trainee - POM 6

7 After use Disconnect the PSS BG 4 closed circuit breathing apparatus: press the button and simultaneously draw the plug-in connector out of the face piece connector Remove mask: Slide your index finger under the ends of the neck straps, press the clamps forwards with your thumbs and evenly pull the mask over your head and off your face. March 26 2009 O2 TNG, MRT Trainee - POM 7

8 Cleaning and Disinfecting Cleaning: The mask must be cleaned whenever it has been used. Position the wiper in the middle of the visor. The mask must be thoroughly rinsed in lukewarm water containing a little all-purpose Sekusept Cleaner and a cloth. Rinse under running water. Disinfection: The mask must be disinfected whenever it has been used. Only use approved disinfectants. Rinse under running water. Drying: Leave mask to dry in drying cabinet or in air. March 26 2009 O2 TNG, MRT Trainee - POM 8


Download ppt "Full Face Masks w/Plug-In Connector Instructions for Use March 26 2009 O2 TNG, MRT Trainee - POM 1 Panorama Nova RP."

Similar presentations


Ads by Google