July 31, 2003Tevatron Alignment Review JCT (Re-)Shimming of Tevatron Dipoles  Recent ‘cold lift’ measurements indicate ‘creep’ or shrinkage of the coil/cryostat.

Similar presentations


Presentation on theme: "July 31, 2003Tevatron Alignment Review JCT (Re-)Shimming of Tevatron Dipoles  Recent ‘cold lift’ measurements indicate ‘creep’ or shrinkage of the coil/cryostat."— Presentation transcript:

1 July 31, 2003Tevatron Alignment Review JCT (Re-)Shimming of Tevatron Dipoles  Recent ‘cold lift’ measurements indicate ‘creep’ or shrinkage of the coil/cryostat support structure (lowering the coil roughly ~3mils) which translates into ~ 1unit of a 1 ; this can corrected by re-shimming  Re-shimming is a well-established procedure that was done hundreds of times in production on magnets at liquid helium temperature  Magnetic effect of re-shimming has been calculated several times and measured many, many times  Re-shimming studies are being carried out in the Magnet Test Facility to verify procedures: a 1 behaves as expected/calculated – not an issue Field angle changes ~.1-.2 mrad – well within alignment ‘budget’ but being studied A brief review of present status

2 July 31, 2003Tevatron Alignment Review JCT (Re-)Shimming of Tevatron Dipoles “Smart” Bolt “Dumb” Bolt Tevatron Dipole Cross Section

3 July 31, 2003Tevatron Alignment Review JCT Measured Change in Cold Lift (from D. Harding)  No change in (Q1-Q2)/2  left-right OK  0.15 mm change in (Q1+Q2)/2  0.1 mm lowering

4 July 31, 2003Tevatron Alignment Review JCT Shimming of Tevatron Dipoles  a 1 due to up-down asymmetry – position or upper-lower coil differences  original corrections made on MTF test stands: measure & shim to <1 unit and ship…  Mean  0.16,   0.53 unit: shimming well understood!

5 July 31, 2003Tevatron Alignment Review JCT a 1  strong coupling, possibly caused by creep in the coil/cryostat support structure relative to yoke that occurred during first years of Tevatron operation Magnet  (cold lift) 82-02 (mils)  (a1) 82-02 (units) TB0269+8.5 / +7.0+1* TC1220+4.1 / +6.0+1* TB0834+11.3 / +11+3* TC0483+4.2 / +6.2+0.4* * '82 and '02/'03 measurements were performed with measurement probes of different lengths at different measurement positions in the magnet body. Therefore the data – although of the right sign and magnitude - are only qualitative: conclusions cannot be drawn yet since there is significant variation of a 1 along the magnet length Magnetic Measurements: a 1 Issue (from P. Bauer)

6 July 31, 2003Tevatron Alignment Review JCT Re-shimming of smart bolts with 3 mils  expected change of 1 unit of a 1 tc1077: 4mil shims at stations 2-8; then, add 4mil shims at stations 1 & 9. Summary of Re-shimming Results (from G. Velev)

7 July 31, 2003Tevatron Alignment Review JCT Field Angle Measurements (from J. DiMarco)  Measure field angle with ‘Stretched Wire’ system before and after re-shimming  Measure ‘Kaiser coil’ angle before and after re-shimming  Measure roll angle (‘Level’) at both ends, before and after re-shimming using antique fixture Four magnets re-shimmed to date – NOTE: units are mrad

8 July 31, 2003Tevatron Alignment Review JCT Kaiser Coil Measurements (from J. DiMarco)  the Kaiser coil is a loop of wire fixed in the yoke, nominally in the vertical plane, used to detect change in coil/cryostat alignment with respect to the iron  Magnet is excited with a AC current and the Kaiser coil is read out after each shim change

9 July 31, 2003Tevatron Alignment Review JCT Kaiser Coil Calibration (from J. DiMarco)

10 July 31, 2003Tevatron Alignment Review JCT Possible causes: Variations of coil position with respect to yoke Coil shape variations, especially between lower and upper pole Dipole tc0525 Probe position number Longitudinal Variation of a 1 (from P. Bauer)

11 July 31, 2003Tevatron Alignment Review JCT (Re-)Shimming of Tevatron Dipoles Summary  Shimming is a well-established procedure  Magnetic effect of shimming is understood  Re-shimming studies carried out in the Magnet Test Facility verify : a 1 behaves as expected/calculated – not an issue Field angle changes (after tilt removed) ~.06-.16 mrad are well within alignment ‘budget’ Additional magnet to be studied  Internal (TD) Readiness review for re-shimming in the tunnel to be held 8/8/03