1 II. WIND TURBINE GENERATOR MODEL
Pitch Angle Control System Figure 3- Pitch Angle Control System Wind power Constant speed wind turbine model

2 II. WIND TURBINE GENERATOR MODEL
Wind power Figure 4- SCIG model in Matlab/simulin

3 III. STATCOM MODEL STATCOM (Static Synchronous Compensator) Coupling transformer (25kV/1.25kV) which ensures coupling between the PWM inverter and the network. voltage-sourced PWM inverter. The PWM inverter is replaced on the AC side with three equivalent voltage sources averaged over one cycle of the switching frequency (1.68 kHz). On the DC side, the inverter is modeled by a current source charging the DC capacitor. LC damped filters connected at the inverter output. Resistances connected in series with capacitors provide a quality factor of 40 at 60 Hz. a microfarad capacitor acting as a DC voltage source for the inverter. voltage regulator that controls voltage at bus. Figure 5- Basic model of a STATCOM Wind power Figure 6- STATCOM model in Matlab/simulin

4 III. STATCOM MODEL The operating principle of STATCOM is as follows:
Figure 7- operating principle of STATCOM The operating principle of STATCOM is as follows: If v = vs (pu values), no current flows through Rtr and Ltr. If v > vs, current flows through Rtr and Ltr. As the impedance is essentially inductive, the current phasor is perpendicular to vs and v voltages. STATCOM injects reactive current to the grid (capacitive current). If v < vs, current flows through Rtr and Ltr. This time the current flows is opposite to the previous, which implies that STATCOM absorbs reactive power from the grid (inductive current). Wind power

5 III. STATCOM MODEL - Phase Locked Loop (PLL). - Measurement systems.
Qref Qmeas Wind power Figure 8- control STATCOM - Phase Locked Loop (PLL). - Measurement systems. - outer voltage regulation loop. - DC voltage controller

6 III. STATCOM MODEL - Phase Locked Loop (PLL). The PLL is synchronized to the fundamental of the transformer primary voltages. - Two measurement systems. Vmeas and Imeas blocks compute the d-axis and q-axis components of the voltages and currents by executing an abc-dq transformation in the synchronous reference determined by sin(wt) and cos(wt) provided by the PLL. - Inner current regulation loop. This loop consists of two proportional-integral (PI) controllers that control the d-axis and q-axis currents. The controllers outputs are the Vd and Vq voltages that the PWM inverter has to generate. The Vd and Vq voltages are converted into phase voltages Va, Vb, Vc which are used to synthesize the PWM voltages. The Iq reference comes from the outer voltage regulation loop (in automatic mode) or from a reference imposed by Qref (in manual mode). The Id reference comes from the DC-link voltage regulator. - Outer voltage regulation loop. In automatic mode (regulated voltage), a PI controller maintains the primary voltage equal to the reference value defined in the control system dialog box. - DC voltage controller which keeps the DC link voltage constant to its nominal value (Vdc=2.4 kV). Wind power

7 IV. SIMULATION RESULT System description
Wind power Figure 9- System model with D-STATCOM

8 IV. SIMULATION RESULT At POC: P and Q Without STATCOM With STATCOM
Wind power Figure 10- Simulation result of P and Q