Presentation is loading. Please wait.

Presentation is loading. Please wait.

LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland. BNL’s Experience dCache1.8 and SRM V2.2 Carlos Fernando Gamboa Dantong Yu RHIC/ATLAS.

Similar presentations


Presentation on theme: "LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland. BNL’s Experience dCache1.8 and SRM V2.2 Carlos Fernando Gamboa Dantong Yu RHIC/ATLAS."— Presentation transcript:

1 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland. BNL’s Experience dCache1.8 and SRM V2.2 Carlos Fernando Gamboa Dantong Yu RHIC/ATLAS computer facility Brook Haven National Lab

2 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.1 Table of Content  BNL’s dCache 1.8 storage and hardware configuration  BNL’s dCache1.8 configuration  Deployment problems  Second re-deployment dCache 1.8 patch level 1  General Commentaries  Future Plans

3 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.2 BNL’s dCache storage and hardware configuration  BNL end point: srm://dct00.usatlas.bnl.gov:8443/srm/managerv2?SFN=//pnfs/usatlas.bnl.gov/data/dteam  Storage class REPLICA-ONLINE (Tape0Disk1)  BNL’s end point hardware specification – CPU speed 3400 MHz – Memory 4149240 KB – This is a server located outside BNL firewall – BNL's firewall not tape storage configured. – Disk space for storage 60GB

4 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.3 BNL’s dCache1.8 configuration  All dCache 1.8 components are installed on same server  Components installed:  SRM V2.2 door  Dcap door  Gridftp door  GSIdcap door  Gplazma cell  3 write pool of 20GB each one  PNFS

5 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.4 BNL’s dCache1.8 configuration (cont.)  Space Manager Configuration – Standar configuration based on dCache’s PoolManager.conf default parameters (1 write link, 1 linkGroup) – VO access control configuration – Group accounts: dteam001, ops001, usatlas5, usatlas4, usatlas3, usatlas2, usatlas1 – VO:ATLAS – Roles: dteamRole=*, /atlas/Role=production /atlas/soft-valid/Role=production

6 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.5 Deployment problems dCache 1.8 patch level 1 System StateTest NameObservation State1 -ReleaseFiles -Move RETURN:SRM_REQUEST_QUEUED After reboot of the dCache system State2 -06_StatusOfBringOnlineReques -09_ReleaseFiles -02_StatusOfPutRequest -04_PutDone, -05_PrepareToGet, -05_StatusOfGetRequest After working around 12 hours RETURN:SRM_REQUEST_Q UEUED State3 -06_BringOnlin -06_StatusOfBringOnlineReque -09_ReleaseFiles The test reported globus-url-copy failed 137 - Stability

7 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.6 Deployment problems dCache 1.8 patch level 1 Files appeared on the write pool not (PnfsManager) admin > cacheinfoof 000100000000000000095F48 cacheinfoof 000100000000000000095F48 No pool was returned However, the file does exist on the pool: [root@dct00 data]# pwd /data/data5/dcache_pool_5/pool/data [root@dct00 data]# ls -l 000100000000000000095F48 -rw-r--r-- 1 root root 2691 May 24 15:01 000100000000000000095F48 Then looking in the admin on the pool (dct00_5) admin > rep ls -l 000100000000000000095F48 rep ls -l 000100000000000000095F48 000100000000000000095F48 2691 si={myStore:STRING} Tracing file from a specific test that reported SRM_REQUEST_QUEUED

8 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.7 Deployment problems dCache 1.8 patch level 1 (cont)  Authentication gPlazma: An entry on the DN of the user is not fully recreated authentication fails; differs from dn stored on kpwd file. Solution Work around: included the USER’s DN without the CN=xxxxx number.

9 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.8 Second re-deployment dCache 1.8 patch level 1 dCache 1.8 Parameter/Component BeforeAfter reinstall Number write pools/size5 / 20GB3 / 30GB Increased the timeout pool120240 srmCopyReqThreadPoolSize 2512 remoteGsiftpMaxTransfers gridftp transfer per pool assumed 54 Mover queue18/pool30/pool dcachesrm-gplazma.policykpwd vo-role-mapping dCache1.8 and pnfs was re-installed.

10 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.9 General commentaries  Tuning Try several values for previous parameters until a stable configuration was found.  Learning curve Would be useful to have examples on using different SRM parameters for tuning purpose.

11 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.10 General commentaries (cont.) Validation Looking forward to install dCache 1.8 patch level 6 and verify if previous strategy can be used to keep passing the tests.

12 LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland.11 Future plans  Update dCache 1.8 patch level1 to patch level 6.  Setup a second test point with access to tape resource.


Download ppt "LCG Storage workshop at CERN. July 2-3 2007. Geneva, Switzerland. BNL’s Experience dCache1.8 and SRM V2.2 Carlos Fernando Gamboa Dantong Yu RHIC/ATLAS."