Synopsis The current PAD incarnation with 119 MHz acquisition fails to resolve pulse shape to required resolution. This resolution is required not only.

Similar presentations


Presentation on theme: "Synopsis The current PAD incarnation with 119 MHz acquisition fails to resolve pulse shape to required resolution. This resolution is required not only."— Presentation transcript:

1 synopsis The current PAD incarnation with 119 MHz acquisition fails to resolve pulse shape to required resolution. This resolution is required not only for DUT RF signals but also for SLED tuning and pulse shaping. PAD resolution is about 40 ns. NLCTA structure tests use GS scopes (Faya) Our effective resolution is 6 bits in our current setup. Recommendation is to go to 12 bit/5ns -> 60dB dynamic range PAC/PAD triggering system in development at TS11 Off the shelf ZTEC EPICS recommendations: – ZT4611 E LXI 2 ch 8 bit $10,810. – ZT4612 E LXI 4 ch 8 bit $17,505 – ZT4422 E LXI 2/4 ch =1/.5 GS 12 bit $13,385.00 ZTEC4612 available for testing G Haller uses EPICS with Acqiris (our current DAQ system)

2 High power RF capabilities From Two 50 MW Klystrons Variable iris Variable Delay line length through variable mode converter Gate Valves Two experimental stations inside the enclosure, one with compressed pulse and the other without the benefit of the pulse compressor. With two 50MW XL4 klystrons ASTA can produce: 100MW @ 1.5 μs --> 550MW @ 63 ns at X-band and feed two experimental outputs in the enclosure. Courtesy of Valery Dolgashev

3 SRS 60 Hz AFG TWTK K llrf configuration I&Q MIXER I&Q MIXER SRS DG645 4 port combiner no SLED SLED Power meters Dark current signals DUT FE/RE Klystron RE Vacuum

4 SRS 60-120 Hz TWTK K rf configuration trigger 4 port combiner no SLED SLED 4 3 6 5 9 11 10 2 1 DUT FC 14 15 I/Q 1,2,3,4,7,8,9Amplitude monitoring100 MHz, power meters, GPIB to EPICs @.1 Hz 5,6KLY RE Machine protection, monitoring 100 MHz, power meters @ 120 Hz 10I/Q pulse shapingHigh resolution/.1 Hz 11,12,13I/Q DAQHigh resolution/ 120 Hz 14,15,16FC DAQ amplitudeHigh resolution/ 120 Hz 7 8 12 13 FC s 16

5 Requirements Purpose 1,2, 3,4, 7,8, 9 Amplitude monitoring 100 MHz, power meters @.1 -1 HzGPIB to EPICs 5,6KLY RE Machine protection, monitoring 100 MHz, power meters @ 120 HzGPIB to EPICs, diode/discriminator 10I/Q pulse shapingGS/.1 Hz, downmixedOnline I/Q feedback 11,1 2,13 I/Q DAQGS/120 Hz 8-12 bit, downmixed2 previous pulses, triggered data dump, offline I/Q, power meter correlation 14,1 5,16 FC DAQ amplitudeGS/120 Hz 8-12 bit2 previous pulses, triggered data dump