Download presentation
Presentation is loading. Please wait.
Published byDana Cook Modified over 8 years ago
1
www.minigrail.nl Ultra-cryogenics for advanced resonant detectors (C2) G.Frossati Kamerlingh Onnes Laboratory Leiden, The Netherlands Second ILIAS-GW Meeting October 24-25 2005 Palma de Mallorca
2
www.minigrail.nl Sensitivity Minimum detectable energy T eff =T/ Q +2T N Need ~0.05; Q~2x10 6 : T~30 mK
3
www.minigrail.nl SQUID noise decreases with T 0.38 0
4
www.minigrail.nl ROG SQUID Double SQUID made of a sensor d.c. SQUID, developed by the Institute of Photonic and Nanotechnologies of CNR, and a commercial Quantum Design d.c. SQUID as a preamplifier. Open input and in open loop configuration: 28hbar at 4.2 K and 5.5hbar at 0.9 K. Feedback network :37hbar in closed-loop open-input 4.2K. With a high-Q resonant input load :70hbar at 2 K.
5
www.minigrail.nl MiniGRAIL Cryogenics
6
www.minigrail.nl Next: 33 ton sphere ? Project together with the Roma group to be submitted to INFN h QL ≈4x10 -24 /√Hz h QL ≈4x10 -23 /√Hz
7
www.minigrail.nl Cooling from 300K Fill liquid helium
8
www.minigrail.nl Forced flow MiniGRAIL 1.3 +1 ton N 2 1200 L 800 L He
9
www.minigrail.nl ROG-Leiden-Geneva project: to be submitted to INFN Use 4 GM cryocoolers for pre-cooling from 300K to 20K Use 4 PT410 for cooling to 4K and for the dilution refrigerator GM600 (Cryomech) 1200W at 250K PT400 60W at 60K and 1W at 4.2k Heat to remove ~70J/gm ~2.8x10 9 J Cool-down time ~2 weeks to 4k SFERA 33 +7 ton 20000 N2 14000 L He !
10
www.minigrail.nl
14
Dilution Refrigeration; Schematic view CIRCULATION SYSTEM STILL HEAT EXCHANGER M IXING CHAMBER HEAT ABSORPTION REGION 1k POT HEAT FLOW T MC
15
www.minigrail.nl Pulsed tube dilution refrigerator Joule Thompson heat exchanger replaces the 1K pot: No need for Helium bath JT Heat exchanger PTR Mixing Chamber 50K 4K 600 mK 60 mK 10 mK
16
www.minigrail.nl
18
Strain sensitivity 2m CuAl6% sphere f=1000 Hz f=100 Hz f=10 Hz MiniGRAIL
Similar presentations
© 2024 SlidePlayer.com Inc.
All rights reserved.