1 How to Connect the Power and Interface (Communication) Cables
Cabling a Rackmounted 9910-P33 UPS i5 or p5 with one PDU or two (redundant) PDUs How to Connect the Power and Interface (Communication) Cables World Trade (WT)

2 Receiving the Rack UPS will be installed in rack
If selected “Rack Install” features in the configurator Connections that need to be completed Power UPS to utility (mains) UPS to PDU / Devices Interface (communications) UPS to server(s)

3 Getting Acquainted with the P33
Location of UPS Installed at bottom of rack Connections rear of rack What a P33 UPS looks like from the rear

4 Line cords & connectors
C13 connector- 10A rated (female) Rack, HD & E PDU outlets Mating connector to server used on P33 and PDU Outlets C14 connector- 10A rated (male) The inlet on most servers & options Rack jumper cords C19 connector- 16A rated (female) P33 Outlet C20 connector- 16A rated (male) P33 inlet and Part of BladeCenter line cord Lower number is female. Power flows from female to male.

5 to one PDU - non- redundant
Power Cabling with one PDU & #9855 to 16A Plug Server power cables to one PDU - non- redundant 520 or 550 with Redundant Power supplies #5158 or #7889 being fed by non-redundant power source PDU #7188 or #9188 PDU line cord #6656 Customer supplied receptacle varies UPS input line cord PN varies UPS output line cord PN 53P1968 (1/2 of #9855) This example shows a server with redundant power supplies being powered by one PDU. Therefore, this installation is classified as non- redundant POWER CORD TABLE FC Description CEE7 VII Type 18 SABS 164 Type 22 CEI Type 25 IEC309 P+N+G 16A Type 46 SII Type 32 SAA-AS 3112 Type 54 IEC A5 Type 64

6 to one PDU - non- redundant
Power Cabling with one PDU & #9855 to 32A Plug Server power cables to one PDU - non- redundant 520 or 550 with Redundant Power supplies #5158 or #7889 being fed by non-redundant power source PDU #7188 or #9188 PDU line cord #6656 Customer supplied receptacle IEC309 P+N+G 32A UPS input line cord PN 53P1969 (1/2 of #9855) UPS output line cord PN 53P1968 (1/2 of #9855) PDU line cord #1449 PN 21H7693 This example shows a server with redundant power supplies being powered by one PDU. Therefore, this installation is classified as non- redundant

7 Power Cabling with two PDUs
2nd or redundant PDU Server power cables to two redundant PDUs PDU #7188 or #9188 PDU line cord #6656 Customer supplied receptacle IEC309 P+N+G 32A 520 or 550 with Redundant Power supplies #5158 or #7889 being fed by redundant power source UPS input line cord PN 53P1969 UPS output line cord PN 53P1968 (1/2 of #9855) Redundant PDU line cord #6656 Customer supplied receptacle IEC309 P+N+G 32A UPS input line cord shown using 30/32A plugs as an example only. PDU line cord #1449 PN 21H7693

8 Interface Cabling i5 to P33
Install i5 UPS Interface Cable #1827 (included with i5) Install UPS to #1827 Interface Cable PN (included with #2936) 520 or 550 UPS port P1-T1 Follow Relay Card Quick Start Guide directions to set UPS monitoring functions in i5 OS Install X-Slot Relay Card #2936

9 Install UPS Interface Cable
Interface Cabling iSeries to P33 Install UPS Interface Cable PN (included with #2936) 8xx Series UPS port “J14” or ”UPS” Follow Relay Card Quick Start Guide directions to set UPS monitoring functions in OS/400 OS Install X-Slot Relay Card #2936

10 Interface Cabling i5 & serial to P33
Install i5 UPS Interface Cable #1827 (included with i5) Install LanSafe Software (contained on CD) onto server Install UPS to #1827 Interface Cable PN (included with #2939) 520, 550 or 570 UPS port P1-T1 Serial (TTY) server Follow Relay / Serial Card Quick Start Guide directions to set UPS monitoring functions in i5 OS and serial (TTY) server. Install UPS to serial Interface Cable PN (with #2939) Install X-Slot Relay / Serial Card #2939

11 Interface - p5 Options Serial (Non-LPAR)
One to three serial connections possible LPAR (Logical PARtitions of the p5 Operating System) Requires a p5 Ethernet connection Must use #2934 Web/SNMP card

12 Interface (Serial) p5 p5 520 or 550 NOTE: Must
NOTE: Obtain Maintenance package (APAR IY66260) for AIX 5.2L V5.2 and the maint. Pkg. For AIX 5.3L V5.3 (APAR IY62267) from IBM Install UPS serial Interface Cable PN (contained in P33 Accessory Kit PN 21P7229) Install LanSafe Software (contained on CD) onto p5 p5 520 or 550 NOTE: Must have 2-port Asynchronous EIA PCI Adapter #5723 Follow Multi-Server User’s Guide to set UPS monitoring functions Multi-Serial Card shown. Your P33 may have a single serial port card.

13 Interface for LPARs (Ethernet) p5
Install NetWatch Software (contained on CD) onto each LPAR Install Ethernet Cable - customer supplied p5 520 or 550 NOTE: Must have Ethernet Port Follow ConnectUPS Web/SMMP User’s Guide to set UPS monitoring functions Install ConnectUPS Web/SNMP Card #2934

14 Completing Start-Up You have finished the power and connectivity installation process Continue with Start-up instructions in User’s Manuals Questions? Contact: The local IBM office supporting your account Eaton Power Quality Global Services