Presentation is loading. Please wait.

Presentation is loading. Please wait.

Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s Established in Athens, Greece in 2002 COMPANY SCOPE.

Similar presentations


Presentation on theme: "Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s Established in Athens, Greece in 2002 COMPANY SCOPE."— Presentation transcript:

1 Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s Established in Athens, Greece in 2002 COMPANY SCOPE The company develops, integrates, and delivers complete solutions in the field of Laser Remote Sensing. We manufacture high-technology LIDAR SYSTEMS and we provideLIDAR Services, maintenance and upgrades related to these instruments a full spectrum of lidar hardware software for data retrieval, instrument control and lidar data analysis

2 Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s LB - Series Lidar systems (Elastic Backscatter) LR - Series Lidar systems (Raman) Ozone DIAL LIDAR systems Design & Development

3 Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s LR-ESS-D200 Eye–safe: Yes Depolarization: Yes, Raman: Yes Vertical or scanning deployment, Mobile: Yes Laser power monitoring, Pre-trigger: upon user request LB–LR D200 Multi-wavelength system Effective range of measurements: from 150 m up to 15-18 km Eye–safe: No Depolarization: Yes, Raman: Yes, up to 6 detected channels Mobile: Yes, Power monitoring, Pre-trigger: upon user request LR –IVU – D400 Multi-wavelength system Effective range of measurements: from 450 m up to the strato- sphere, Eye–safe: No Depolarization: Yes (2), Raman: Yes (2), Water vapor: Yes Mobile: Yes / Laboratory version also possible Laser power monitoring, Pre-trigger: upon user request

4 Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s Multi-wavelength Ozone/Aerosol DIAL system (266-289-299-316-532S/P-1064 nm) Effective range of measurements: from 800 m up to 15-20 km (up to 60 km upon request) Daytime - nigh-time operation Eye–safe: No Up to 7 detection channels Transportable Laser power monitoring, Pre-trigger: upon user request Airborne version: available upon request

5 Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s CUSTOMIZATION

6 Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s LICEL Acquisition System Open source software for: Data acquisition System checking and controlling Lidar data analysis Ascii files, Binary files or NetCDF Fully simulated: ray-traced and mechanically, +/- 45 o depol. Calibration procedure, Telecover Tests etc.

7 Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s

8 Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s INDIA New Multiwavelength Lidar System

9 Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s INDIA New Multiwavelength Lidar System


Download ppt "Second GALION Workshop, WMO, Geneva, 20 ‐ 23 September 2010 A d v a n c e d L I D A R S y s t e m s Established in Athens, Greece in 2002 COMPANY SCOPE."

Similar presentations


Ads by Google