Presentation is loading. Please wait.

Presentation is loading. Please wait.

Infrasound detector for Apatity group Asming V.E., Kola Regional Seismological Center, Apatity, Russia.

Similar presentations


Presentation on theme: "Infrasound detector for Apatity group Asming V.E., Kola Regional Seismological Center, Apatity, Russia."— Presentation transcript:

1 Infrasound detector for Apatity group Asming V.E., Kola Regional Seismological Center, Apatity, Russia

2 Layout of Apatity seismic and infrasound groups

3 Let F si - i-th band-pass filtered sample of sensor s i - index of a sample, i=1,N samples s - index of a sensor, s=1,N sensors Consider a plain wave arriving from backazimuth  and and with an angle  to the day surface (tangage angle). The time delays of the wave arrivals to the array’s sensors are  t s ( ,  ) = (  X s cos  +  Y s sin  ) cos  / v sound Expressed in numbers of samples, the delays are  i s ( ,  ) =Round(  t s /h) Beamforming-style detector of acoustic signals

4 Consider two kinds of beams for each ( ,  ) a) Average beam b) Maximal beam In idealized case when ( ,  ) are true parameters of an incident plain wave, all sensors have the same response and there are no noise and signal attenuation due to relief A i =M i, otherwise A i < M i

5 Basically we may use the ratio A i /M i for detection but there may be uncertainties when M are small. To avoid this we use window averaging of A i and M i : - has a meaning of coherency between recordings at different sensors and can be used as a detector

6 BUT:amplitudes of a signal can be different at different sensors (up to 1.5 times). The differences depend on a direction of a wave propagation. Probably due to relief. This can diminish the ratio R j. If we take smaller values for threshold we significantly increase a number of false alarms. To avoid this we use the following “trick” : we calculate “normalized” recordings where N norm >>N aver And by we compute as described above

7 If to use as a detector a new source of false alarms appears when pieces of recordings of very different amplitudes have high coherency Finally, we decided to use ratios R calculated by both normalized and non-normalized data. And the detector appeared to be: where typically 0.6-0.65 versus 0.75-0.8 and

8 The detector described above does not use amplitudes Indeed, weak but obviously true events do exist

9 To separate events by signal-to-noise ratio we implement a statistical algorithm to noise level estimation by average amplitude Estimated noise level

10 Implementation for Apatity array A PC program which can process CSS 3.0 data or a data stream from Apatity array

11 Band-pass filter:1-5 Hz Length of averagingN aver :20 samples (0.5 sec) Length of normalizing N norm :100 samples (2.5 sec) Tangage angles (  ):0, 20, 40, 60 degrees Azimuth angles (  ):0-359 degrees, step 1 Threshold for initial ratio:0.6 Threshold for norm ratio:0.75 The detector parameters

12 Results for 01.12.2005-22.12.2005 2263 events

13 464 events with SNR>15

14 Explosions detected by Apatity system

15 Typical wave forms of infrasound events Event from South, band-pass filtered 1-5 Hz

16 One of the strongest events (SNR=216)

17 Weak but obviously true event, filtered 1-5 Hz (SNR=10)

18 How to locate infrasound events ? Error of backazimuth estimation = 1°

19 Error of backazimuth estimation = 2°


Download ppt "Infrasound detector for Apatity group Asming V.E., Kola Regional Seismological Center, Apatity, Russia."

Similar presentations


Ads by Google