Open Channel Flow Closed pipe Pump or fan driving force No free surface Open channel Gravity driving force Free surface.

Similar presentations


Presentation on theme: "Open Channel Flow Closed pipe Pump or fan driving force No free surface Open channel Gravity driving force Free surface."— Presentation transcript:

1 Open Channel Flow Closed pipe Pump or fan driving force No free surface Open channel Gravity driving force Free surface

2 Open channel Irrigation Storm water collection Waste treatment Transport

3 Open channel Prismatic channel Hydraulic radius R h = flow area/wetted perimeter Optimize for greatest flow at smallest wetted perimeter

4

5

6 Open channel Flow determination Empirical Manning Equation Weirs

7 Manning equation USCS: cfs Q = (1.49/n)A R h 2/3 S o 1/2 Manning coefficient: n depends on channel surface smoothness

8 Weirs Obstruction in flow channel Sharp-crested weirs Rectangular V-notch

9

10

11 Open Channel Lab All data in USCS Obtain measurements for slope calculations

12 Part 1 Flow valve wide open; allow flow to stabilize Record flow meter value Record dimensions for Manning equation Install rectangular weir; obtain dimensions Install v-notch weir; obtain dimensions

13 Part 2 Adjust flow valve to reduce flow to about 50% of flow in Part 1 Repeat all measurements

14 Report Data: dimensions and flow meter readings Results: calculated flows from Manning Equation and two weirs Conclusions: compare flow meter readings with those obtained from empirical equations