Presentation is loading. Please wait.

Presentation is loading. Please wait.

MAGNETO-OPTICAL CURRENT TRANSFORMER.

Similar presentations


Presentation on theme: "MAGNETO-OPTICAL CURRENT TRANSFORMER."— Presentation transcript:

1 MAGNETO-OPTICAL CURRENT TRANSFORMER

2 CONTENTS CURRENT TRANSFORMER MOCT – principle ,working ,design
MOCT BLOCK DIAGRAM APPLICATIONS ADVANTAGES DISADVANTAGES CONCLUSION

3 CURRENT TRANSFORMER: CT CONSTRUCTION: CT WORKING PRINCIPAL:
Inductive type transformer with core and primary & secondary windings. CT WORKING PRINCIPAL: Step up transformer (voltage), step down transformers (current). PURPOSE OF CT It feeds the current coils of indicating ,metering instruments and protective relays. Watch over the current’s in the circuit. DISADVANTAGES OF CT: The insulation structure has to be designed carefully to avoid electric field stress, which could eventually cause insulation breakdown. Less reliability

4 MOCT MOCT Measures the electric current by means of FARADAY EFFECT.
“Michael Faraday discovered that the orientation of linearly polarized light was rotated under the influence of the magnetic field when the light propagated in a piece of glass, and the rotation angle was proportional to the intensity of the magnetic field. “

5 Polarization is a property of certain types of waves that describes the orientation of their oscillations.

6 FARADAY EFFECT ANGLE=n*permeability*VI -------------(2)
By considering the property faraday given two mathematical equations ANGLE=V (INTEGRAL OF B) (1) ANGLE=n*permeability*VI (2)

7 POLARIZER MAGNETO-OPTICAL MATERIAL ANALYZER (POLARIZATION PRISM) PHOTODIODES

8 MOCT

9 BLOCK DIAGRAM OF MOCT

10 APPLICATION The MOCT is designed to operate in a transparent manner with modern electronic meters and digital relays, which have been adopted for a low energy analog signal interface.

11 ADVANTAGES No risk of fires and explosions.
No need to use metallic wires to transfer the signal. High immunity to electromagnetic interference. Larger dynamic range. Low voltage outputs which are compatible with the inputs of digital to analog converters.

12 DISADVANTAGES Due to Temperature and stress induced linear changes in the sensing material causes error and instability. The accuracy of MOCT is some what less than the conventional transformer. Main cause is temperature drift But the disadvantages can be overcome by implementing the Double closed-loop self-tuning method

13 CONCLUSION This paper presents a new kind of current transducer known as magneto optical current transducer. This MOCT eliminates many of the drawbacks of the conventional current transformers. By applying Faraday’s principle this transducer provides an easier and more accurate way of current measurement. This MOCT is widely used in power systems and substations nowadays.