Minhye Chang. Introduction Evolution Battery-Powered BION System Applications Proceedings of the IEEE.

Similar presentations


Presentation on theme: "Minhye Chang. Introduction Evolution Battery-Powered BION System Applications Proceedings of the IEEE."— Presentation transcript:

1 Minhye Chang

2 Introduction Evolution Battery-Powered BION System Applications Proceedings of the IEEE

3 * Low-level electrical current to nerves or reflex centers * Triggered by single switch(open-loop) neuronal activity(closed-loop) * Limb loss applications Reduce phantom pain Restore functional movement IntroductionEvolutionSystemApplications

4 * Provide both stimulating and sensing capabilities * Be fully implantable * Be minimally invasive * Have real-time communication capability * Practically unlimited number of stimulation and sensing channels * Function w/o external equipment or interconnected leads btw components IntroductionEvolutionSystemApplications

5 Extensive surgery 20-plus channel Nucleus FES22 requires more than 15h of surgery Infection of Large Continuous Implant Surfaces Bacterial infection spread to the entire implant. The only remedy is to explant the entire system. RF Powered Device Problems Maintaining proper orientation of the power transmitting antenna The discomfort of wearing an antenna and a battery powered transmitter Lack of Coordinated Sensors and Stimulators Other than demand pacemakers, very few attempts to use implantable sensors Extensive Advanced Planning Each condition usually requires a unique sensor system The number of channels, the type of sensors and signal conditioning, and etc. IntroductionEvolutionSystemApplications

6 * As either stimulators or sensors * Minimally invasive implantation * Wireless, real-time bidirectional communications * Flexibility and functional expandability w/o leads * A large number of channels * Self-powered operation IntroductionEvolutionSystemApplications

7 RF-powered Allow instantaneous control Prevent electrostatic discharge Need to wear an external coil Battery-Powered To improve patient acceptance To increase the reliability Operate for more than ten years By Quallion. Capacity of 10mWH, operating at a voltage of 3.6V IntroductionEvolutionSystemApplications

8 * For urinary incontinence * The 1 st BION to have two- way telemetry * Very short time for synchronization * Lack of sensing capabilities * Slow communication response time * Wireless * Fully implantable * Data processing for sensed signals * Rechargeable * Long term immersion weakens ceramic  improve longevity IntroductionEvolutionSystemApplications

9 * Improved IC Increase the compliance voltage of the RF-powered microstimulator Modified the demodulation circuit * Combining the IC and the ferrite Longer and more efficient coil in receiving energy from the ac magnetic field * Ceramic case * Internal capacitor Prevents continuous direct current from flowing into the tissue IntroductionEvolutionSystemApplications

10 * Defibrillator protection Prevents damages from static electricity in the operating room * Eyelet Enables a simple removal within about a week or more * Insertion System * Human experiments 42 RF microstimulators in six stroke patients Ultrasonic and magnetic resonance image viewing IntroductionEvolutionSystemApplications

11 * Stimulating lead system failure Stimulation amplitude and low current range was unstable * Automatic tuning of AC powering coils Need a very precise tuning frequency in coil to save battery power A crystal controlled oscillator and a bank of about eight capacitors in the external control unit * Hermetic and electrolytic corrosion free braze joints IntroductionEvolutionSystemApplications

12 * Arm coil system Microstimulators btw the wrist and elbow To produce a magnetic field, two coil pairs are connected in series * Clinicians automatic test system The fitting notebook station an automatic microstimulator tester Test regime will verify nearly every connection in the microstimulator IntroductionEvolutionSystemApplications

13

14 Communication and control hub External MCU: a few controls accessible to the patient Implantable MCU: small patient control unit (PCU) IntroductionEvolutionSystemApplications

15 * Transmits and receives data up to 850 BPBs within 1/100s * Basic user interface System ON/OFF control, alarms, program selection and limited parameter control * During fitting, enables the setup and the coordination * Manages the recharging subsystem * Safety mechanisms Emergency STOP button When BPB overheats or overcharges * Stores patient usage data and the approximate location of BPBs IntroductionEvolutionSystemApplications

16 Allows the clinician to configure and test IntroductionEvolutionSystemApplications

17 * During the fitting, CP & MCU facilitate measurement and storage of the stimulation and sensor calibration parameters * During the stand-alone mode, essential information is stored in the MCU * Clinician’s programmer Gather basic personal information Establish the stimulation range and allow selection of the stimulation parameters Specify the activity sequences Gather the trigger information Compose the Finite State Machine functions IntroductionEvolutionSystemApplications

18 Place the coil close to the area Battery Depend on the frequency and stimulation levels Run in 1 to 8 days Charging for about 5 to 20 min per day IntroductionEvolutionSystemApplications

19 Transmits only power Each BPB Charging and battery status IntroductionEvolutionSystemApplications

20 * 12-kHz signal to generates a magnetic field * MCU Determines which BPB to be charged and when to charge Indicates to the patient where the coil must be moved Selects the most discharged device * Temperature sensor that stops the process when the external coil overheating IntroductionEvolutionSystemApplications

21 Safety feature when Undesired manner No access of the patient to control unit Magnet is positioned On the body  holds off the stimulation On the other part  stimulation turns on Small, light weight, very strong magnetic signal IntroductionEvolutionSystemApplications

22

23 * Single-channel, constant- current, charge-balanced stimulator * Capacitance-coupled output prevents direct connection btw battery and tissue. * Pulse amplitude, width, and frequency * Triggering events * Dipole antenna * Crystal-controlled transmitter, receiver, & digital processing unit * Digital processing unit Corrects errors in data and communication Decodes the MCU commands Generates the responses to the MCU IntroductionEvolutionSystemApplications

24 For frame synchronization and frame control data Stimulation and/or sensing control data Forward error correction (FEC) bits Information to MCU FEC for 1 or 2bit errors IntroductionEvolutionSystemApplications

25 * 10-mW-hr rechargeable lithium-ion battery * Recharging via 127kHz magnetic link * Provide 100 hours of operation * Deep discharge  lifetime of more than ten years * Miniature magnetic sensor * Temperature sensor for terminating charging * Battery safety circuitry Overvoltage, overdischarge, and overcharging * For themselves for maximum charging IntroductionEvolutionSystemApplications

26 * “Oscilloscope mode” during fitting * Data analysis Count pulses: accumulated pulses every 10ms Rectify and integrate every 10 ms * Along the axial dimension of the BPB * 400~900 mmHg * AC/DC coupled * Altitude changes  reference sensor in the MCU IntroductionEvolutionSystemApplications

27 * Distance btw two BPBs Intensity of the received magnetic field One BPB as a transmitter, and other BPBs as a receiver Receiver BPB detects and measures the signal strength No limit to the number of BPB receivers Measure distances btw 1~20cm * 8 parallel systems whose frequencies are around 127kHz * As a safety mechanism * Accurate to within 0.33 ˚C * Range 16~50 ˚C * Taken once per second IntroductionEvolutionSystemApplications

28 * Minimally invasive procedure 1 st test during the implantation 2 nd test right after the implantation 3 rd test one week after implantation A: Probe Electrode B: Dilator C: Sheath D: Ejection Tool E: 3ml Syringe IntroductionEvolutionSystemApplications

29 * As a stimulator, biopotential signal sensor, goniometry sensor, pressure or temperature sensor Multiple BPBs; up to 850 BPBs Near motor-points or nerves of muscles in the arm, forearm, and hand * To extend the arm and forearm, and open the hand to grasp an object As goniometry sensors and pressure sensors * Sensing of the muscle activities acts as triggers to other BPBs to stimulate the motor-points Standing, ambulation, swallowing, bladder control, and respiration * Measuring pressure and triggering motor-point or stopping a FES sequence At the heel, the buttock, or hand IntroductionEvolutionSystemApplications

30 * As biopotential sensors * Inserted in the “stump” * Pick up motor nerve signals to control movement IntroductionEvolutionSystemApplications

31 * Voluntary motion is regained * By monitoring the motor cortex * By feeding back sensed response signals to the sensory cortex * Cortical interface device (CID) * Base unit implanted in the skull monitors up to several hundred electrodes * Electrode arrays placed on the sensory or motor cortices IntroductionEvolutionSystemApplications

32 * CID base unit Equivalent to a group of sixty-four BPBs Sixty-four biopotential sensing modules Either unipolar or bipolar Same technology developed for the BPB * Sensing electrode array Include signal processing capability like biopotential sensing module in the BPB same stimulation electronics like the BPB stimulation module IntroductionEvolutionSystemApplications