André Vézina, ITA, La Pocatière Campus Planning a Shelterbelt April 2006.

Similar presentations


Presentation on theme: "André Vézina, ITA, La Pocatière Campus Planning a Shelterbelt April 2006."— Presentation transcript:

1 André Vézina, ITA, La Pocatière Campus Planning a Shelterbelt April 2006

2 André Vézina, ITA, La Pocatière Campus Site selection  Odour reduction  Snow accumulation  Building visibility  Other factors:  Heating costs  Type of ventilation

3 André Vézina, ITA, La Pocatière Campus W/H = 8 26% reduction W/H = 0.6 92% reduction Odour reduction varies with W/H ratio (Liu et al., 1996) Odour source

4 André Vézina, ITA, La Pocatière Campus Snow accumulation attributable to shelterbelt  A 30-metre distance is recommended (from prevailing winds) between the shelterbelt and the installations to be protected in order to allow snow to accumulate.

5 André Vézina, ITA, La Pocatière Campus Remove from sight… complaints will drop  Origin of complaints should be taken into account.

6 André Vézina, ITA, La Pocatière Campus Reducing heating costs  Building should be located at 2-4 H of the hedge to be in the optimal wind speed reduction area.

7 André Vézina, ITA, La Pocatière Campus Type of ventilation  With natural ventilation: allow sufficient space (8 H) between the hedge and the building to allow air streams to flow back down.

8 André Vézina, ITA, La Pocatière Campus Height  Hedge height target is 15 m, especially in cases where heating costs reduction is an added protection objective.  Shrubs and small trees can also do well when the key objective is to remove buildings from sight.

9 André Vézina, ITA, La Pocatière Campus 25 N Prevailing winds 25

10 André Vézina, ITA, La Pocatière Campus Prevailing winds Property lines