Presentation is loading. Please wait.

Presentation is loading. Please wait.

Mammography.

Similar presentations


Presentation on theme: "Mammography."— Presentation transcript:

1 Mammography

2 Introduction and History
Breast cancer is 2nd only to lung cancer as cause of death in women Very treatable with early detection! 1st innovation since radical mastectomy introduction in 1898 In 1913, radiographic appearance of breast cancers was first reported Mammography became a reliable diagnostic tool in 1950s when industrial grade x-ray film introduced

3 History Of Mammography (cont’d)
1960’s – Xerography introduced – much lower dose Research conducted in 1970s clearly showed mammography to be essential part of early diagnosis 1975 – High speed/resolution film introduced by DuPont 1992 – MQSA implemented (Mammography Quality Standards Act)

4 Occurs in both men and women (male breast cancer is rare)
Definition of breast cancer: Cancer that forms in tissues of breast, usually ducts (tubes that carry milk to nipple) and lobules (glands that make milk). Occurs in both men and women (male breast cancer is rare)

5 MQSA Mammography was 1st and only federally regulated imaging exam with implementation of Mammography Quality Standards Act (MQSA) Mandated following: Formal training and continuing education Required regular inspection of equipment Documentation of quality assurance Reporting results, follow-up, tracking pts, and monitoring outcomes

6 Principles Of Breast Cancer
Pt.s in early stages respond well to treatment Patients with advanced disease do poorly Earlier diagnosis, better chance of survival Mammography is tool for early detection

7 Risk v. Benefit More risky to refuse mammography!
Breast cancer in United States in 2009 (estimated): New cases: 192,370 (female); 1,910 (male) Deaths: 40,170 (female); 440 (male) Us population 306 million in deaths /million Mortality risk from mammography induced radiation is 5 deaths/ million pts. using screen film mammography More risky to refuse mammography!

8 Breast Cancer Screening
Very 1st Mammogram is Baseline (or first mammo. after surgery) There after: screening mammogram pt. must be asymptomatic – no known breast problems American Cancer Society and American College of Radiology recommend screening annually for women over age 40

9 Diagnostic Mammogram For woman presenting with clinical evidence of breast disease, palpable mass or other symptom Uses specific projections to Rule out cancer Demonstrate suspicious area seen on screening mammogram

10 Breast Cancer Risk Factors
Risk increases with age Hormonal history Risk increases with early menses, late menopause, pregnancy after age 30, or nulliparity Family history Risk increases -daughter, mother, or sister has breast cancer

11 Breast Anatomy Breast same as mammary gland
Lobulated, glandular structures located in superficial fascia of anterolateral wall of thorax Secondary sex characteristic

12 Base of breast overlies pectoralis major and serratus anterior muscles
Part of breast extends into axillary fossa

13 Anatomy (cont’d) Breasts vary in size and shape!
Consist of glandular, fat, and muscle tissue

14 Breast Anatomy Lobule size affected by age and hormones
Involution: process of decreasing lobule size with age and after pregnancy

15 Anatomy The breast tapers anteriorly ending in the nipple
Encircled by areola: area of pigmented skin Breasts are supported by Cooper’s ligament which determines firmness or lack thereof Female breasts are divided into 15 – 20 lobules

16 Breast Anatomy Each lobe divided into many lobules
Lobules are basic structural unit of breast Lobules contain Several acini Draining ducts Interlobule stroma (connective tissue)

17 Breast Anatomy Lymphatic vessels of breast drain into two sets of nodes Axillary lymph nodes, laterally Internal mammary lymph nodes, medially Axillary nodes are often evaluated on mammograms

18 Tissue Variations Breasts -glandular and connective
Ability to visualize depends upon amount of fat within and around breast lobules- provides contrast Postpuberty breasts contain primarily dense connective tissue

19 During pregnancy, breasts undergo hypertrophy

20 Fatty tissue replaces glandular tissue after lactation and advancing age
After menopause, glandular tissue begins to atrophy

21 Typical Mammography Unit
Equipment is C-arm SID is fixed at 24 – 26”

22 Mammography Equipment
Dedicated units have high-frequency generators Provide more precise control of kVp, mA, and exposure time Specially designed to produce high-contrast and high-resolution images

23 Mammography uses Low kVp : 25 – 28 AEC
Anode material made of molybdenum, with rhodium target Grid with ratio: 4:1, or 5:1 200 lines/inch

24 Magnification Increases visibility of small structures Increase OID
Uses air gap Radiation dose increases with magnification

25 Compression Device Compression decreases thickness of breast, magnification and scatter Increases contrast Reduces motion unsharpness Reduces dosage

26 Compression Device Made of firm plastic
Amount of compression: between 25 and 40 pounds pressure Compression may be uncomfortable!

27 Screen-Film Systems Mammography cassettes contain a single screen
Film is single emulsion Occasionally, extended time processing is used (reduces dose and increases contrast)

28 Digital Mammography State of the art! No film or chemical processing
Images easily sent over internet Much better definition Possible downside-if 1st digital compared to previous film mammo., can give false positives due to increased sensitivity! - Slightly higher dosage

29 Procedure Complete, careful history and physical assessment
Take notes on location of scars, palpable masses, skin abnormalities, and nipple alterations Examine previous mammograms for positioning, compression, and exposure factors

30 Procedure (con’t) Patients dress in open-front gown
Breasts must be bared for imaging Cloth will cause image artifact Remove deodorant and powder from axilla and breast Can mimic calcifications on image

31 Procedure (cont’d) Explain procedure to pt., including possibility for additional projections Consider natural mobility of breast before positioning Support breast firmly so that nipple is directed forward Profile nipple, if possible

32 Positioning

33 Procedure Apply proper compression to produce uniform breast thickness
Essential to high-quality mammograms Place ID markers according to standard convention

34 Routine mammography projections
Craniocaudal (CC) Mediolateral oblique (MLO)

35 Craniocaudal Projection
Patient position Standing or seated facing IR holder Part position Elevate inframammary fold to maximum height Adjust IR height to inferior surface of breast Gently pull breast onto IR holder with both hands while instructing patient to press chest to IR holder

36 Craniocaudal Projection
Arrange breast on film so nipple is in profile and maximum amount of breast tissue is radiographed CR – Perpendicular to base of breast Structures – Central, subareolar, medial fibroglandular breast tissue, pectoral muscle

37 Craniocaudal Positioning (cont’d
Immobilize breast with one hand Use other hand to move opposite breast out of image Shoulder relaxed in external rotation

38 Craniocaudal Projection (cont’d)
Rotate head away from breast being examined (watch out for hair!) Lean pt. toward machine Place hand on shoulder and slide skin over clavicle Compress breast slowly until skin taut

39 CC Projection

40 Mediolateral Oblique Projection
Position Center breast with nipple in profile, if possible Hold breast up and out Compress breast slowly until taut Pull down on abdominal tissue to open inframammary fold

41 Mediolateral Oblique positioning
Instruct pt. to hold opposite breast laterally, out of anatomy of interest Exposure on suspended respiration Release compression immediately!

42 Mediolateral Oblique Open inframammary fold
Deep and superficial breast tissues well separated Retroglandular fat well seen Uniform tissue exposure If compression is adequate

43 Mediolateral Oblique Degree of obliquity is 30° to 60°
Depends on body habitus Tall, thin patients require steeper angulation CR perpendicular to base of breast Structures – lateral aspect of breast and axillary tail

44 Mammographer’s Nightmare

45 Radiography Of Augmented Breast (implants)
8 projections must be obtained (2x4) MRI and sonography can help determine rupture or leakage Four standard images with implant displaced posteriorly into chest wall are obtained

46 Breast Implants

47 Saline vs Silicone Some surgeons feel silicone implants have a more natural look and feel because silicone gel texture similar to breast tissue. Silicone implant ruptures are harder to detect. When saline implants rupture, they deflate -results are seen almost immediately. When silicone implants rupture, breast often looks and feels same because silicone gel may leak into surrounding areas of breast without a visible difference. Replacing a ruptured silicone gel implant is more difficult than repairing saline implant. Silicone implants have higher rate of capsular contracture (scarring and hardening around implant). Saline implants inflated to desired size with saline, then valve is sealed by surgeon

48 Implants can be in front of pectoral muscle or behind

49 Radiography Of Augmented Breast (implants)
Complications: Increased fibrous tissue surrounding implant (contracture) Shrinking Hardening Leakage Pain

50 Male Mammography Approximately 1000 males develop breast cancer every year Standard CC and MLO are obtained Males not screened- mammogram only if lump discovered

51 Gynecomastia

52 Imagine Living without Man boobs!
If someone would've said to picture my life without man boobs, I couldn't.  Sad but true. How do you picture a life without something you'd had your entire life? I'd learned to live with them... the hiding... the put-downs... $100,000 one year

53 Treatment For Breast Cancer
Lumpectomy Partial or radical mastectomy Radiation Chemotherapy

54 CC view ( lesion)

55 Needle Localizations Used to localize breast lesions before surgery
Special, open-hole plate may be used for ease of localization Plate contains grid to plot coordinates Operative stereotactic surgery may be used Two offset images are obtained to create a 3-dimensional image

56 Needle Localization

57 Breast Specimen Radiography
Performed after surgery once lump has been excised Determines extent of calcifications within specimen Magnification technique may be used

58 Breast Specimen Radiograph

59

60 24 yr. old (has children) 19 yr. old (never pregnant)

61 Calcified Milk Ducts

62

63 Various abnormal mammograms

64 The End