Date/ event: Author: WISE-SoE / WFD station matching for SW and GW Miroslav Fanta ETC Water Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water
2
Date/ event: Author: The Objectives of the Activity for the continuity of time series, we need to identify surface water (rivers, lakes) and groundwater WISE-SoE monitoring stations which are identical with the monitoring stations reported under WFD Article 8 (stations matching) for the continuity of time series, we need to identify surface water (rivers, lakes) and groundwater WISE-SoE monitoring stations which are identical with the monitoring stations reported under WFD Article 8 (stations matching) specification of countries and water categories for which the match is poor specification of countries and water categories for which the match is poor Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water
3
Date/ event: Author: Input Datadets WISE-SoE monitoring stations reported by countries by water type categories (rivers, lakes, groundwater quality reporting) – yearly update - status Spring 2009 WISE-SoE monitoring stations reported by countries by water type categories (rivers, lakes, groundwater quality reporting) – yearly update - status Spring 2009 list of WFD Article 8 stations managed by EEA – continuously updated – status September 2009 (44 887 rivers stations, 5 898 lakes stations, 55 392 groundwater stations) list of WFD Article 8 stations managed by EEA – continuously updated – status September 2009 (44 887 rivers stations, 5 898 lakes stations, 55 392 groundwater stations) Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water
4
Date/ event: Author: Methodology used for Stations Matching identical station code or decisive part of the code (EU_CD, MS_CD) identical station code or decisive part of the code (EU_CD, MS_CD) equal (or nearly equal) station coordinates equal (or nearly equal) station coordinates identical or nearly identical name (supportive criteria) identical or nearly identical name (supportive criteria) station was tagged by country as WFD Art.8 station within WISE-SoE reporting and EU_CD code was provided station was tagged by country as WFD Art.8 station within WISE-SoE reporting and EU_CD code was provided Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water
5
Date/ event: Author: Results and Statistics - Rivers Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water Number of all WISE-SoE stations 7 749 Number of EU27 WISE-SoE stations 7 442 WISE-SoE stations matched with WFD by equal or nearly equal coordinates 5 669 WISE-SoE stations matched with WFD by code (international, national) or name 4 871 WISE-SoE stations matched with WFD by coordinates or code or name 6 273 = 84.3 % of EU27 stations WISE-SoE stations matched with WFD by coordinates or code or name and active during the period 2004 - 2007 5 166
6
Date/ event: Author: Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water River stations matching
7
Date/ event: Author: River stations matching - detail
8
Date/ event: Author: Results and Statistics - Lakes Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water Number of all WISE-SoE stations 2 544 Number of EU27 WISE-SoE stations 2 201 WISE-SoE stations matched with WFD by equal or nearly equal coordinates 317 WISE-SoE stations matched with WFD by code (international, national) or name 859 WISE-SoE stations matched with WFD by coordinates or code or name 1 176 = 53.4 % of EU27 stations WISE-SoE stations matched with WFD by coordinates or code or name and active during the period 2004 - 2007 1 176
9
Date/ event: Author: Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water Lake stations matching
10
Date/ event: Author: Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water Lake stations matching - detail
11
Date/ event: Author: Results and Statistics - Groundwater Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water Number of all WISE-SoE stations 15 269 Number of EU27 WISE-SoE stations 14 982 WISE-SoE stations matched with WFD by equal or nearly equal coordinates 6 056 WISE-SoE stations matched with WFD by code (international, national) or name 7 443 WISE-SoE stations matched with WFD by coordinates or code or name or confirmed by country as WFD Art. 8 station 7 986 = 53.3 % of EU27 stations WISE-SoE stations matched with WFD by coordinates or code or name or confirmed by country as WFD Art. 8 station and active during the period 2004 - 2007 7 535 = 62.3 % of active EU27 stations
12
Date/ event: Author: Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water GW stations matching
13
Date/ event: Author: GW stations matching - detail
14
Date/ event: Author: Conclusion of Stations Match good match for river monitoring stations (84%) good match for river monitoring stations (84%) lower matching for lakes and groundwater (about 53%) lower matching for lakes and groundwater (about 53%) variation between countries variation between countries close cooperation and feedback with some Member Countries is needed during data processing to improve the results close cooperation and feedback with some Member Countries is needed during data processing to improve the results Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water
15
Date/ event: Author: Matching of Groundwater Bodies matching of EIONET groundwater bodies with WFD Article 5 groundwater bodies = fully identical delineation of gw bodies in both cases matching of EIONET groundwater bodies with WFD Article 5 groundwater bodies = fully identical delineation of gw bodies in both cases WFD groundwater bodies should be used from now on WFD groundwater bodies should be used from now on some countries report groundwater data aggregated by groundwater bodies (BE, FI, HU, LU, MT, NL, RO) some countries report groundwater data aggregated by groundwater bodies (BE, FI, HU, LU, MT, NL, RO) Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water
16
Date/ event: Author: Statistics of GW Bodies Matching statistics based on Member States reporting (identical delineation of GW bodies) Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC WaterCountry SoE gw bodies + WFD gw bodies used by countries within WISE-SoE reporting WFD gw bodies used by countries within WISE-SoE reporting Matching SoE and WFD gw bodies with identical identifiers Matching SoE and WFD gw bodies with different identifiers % of SoE gw bodies matching WFD gw bodies BE1105555100 BG2701076942 CY333100 FR307356455922 HU54181850 LU115583 LV20161680 MT222100 SE45212187.5
17
Date/ event: Author: Matching of Groundwater Bodies aim of this exercise: not to interrupt time series of data reported as aggregated by gw body additional matching rule (not used up to now): In case the area of ground water body covers identical sources of monitoring, such ground water bodies can be matched even if their spatial delineation is slightly different. Countries will be asked for cooperation to specify such pairs of gw bodies. Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water
18
Date/ event: Author: Matching of Groundwater Bodies missing matching for: missing matching for: GR, NL, RO, UK several other countries reported aggregated data in earlier period (e.g. ES 1985 – 1999) gw bodies not matched => redelivery of the time series aggregated per WFD gw bodies or, preferably, as disaggregated data gw bodies not matched => redelivery of the time series aggregated per WFD gw bodies or, preferably, as disaggregated data Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water
19
Date/ event: Author: Thank you for attention Freshwater EIONET Workshop – Copenhagen, October 2009 Miroslav Fanta, ETC Water