1 Kyland-USA, Kansas City, MO DYMEC is a registered trademark of Kyland-USA

2 Kyland-USA, Kansas City, MO Kyland-USA DYMEC Industrial Ethernet Product Training Welcome !

3 Kyland-USA, Kansas City, MO Kyland-USA Tom West – Engineering Ray Renaud – VP Channel Sales

4 Kyland-USA, Kansas City, MO Kyland-USA Overview Kansas City, Missouri ECO-Engineering Company Veteran Owned Small Business Made in USA products Energy Conservation Focus on IP Industrial Security

5 Kyland-USA, Kansas City, MO POE Switches with CYBER-SECURE Video & 802.3az (Green Scheduling)

6 Kyland-USA, Kansas City, MO DYMEC is a registered trademark of Kyland-USA POWER OVER ETHERNET

7 Kyland-USA, Kansas City, MO Overview PoE Technology How PoE works Kyland-USA PoE Products

8 Kyland-USA, Kansas City, MO Power Over Ethernet CYBER-SECURE VIDEO Jumbo Frame & Clean Code Technology Redundant Trunk Link (RTG) Support QOS/PRIORITY Classes by Application HD Camera Ready 802.3az (Green Scheduling) Power Saving Operations Industrial Ethernet Switches Temperature Hardened 5 Year Warranty Redundant Uplinks Managed & Unmanaged All Gigabit Ports Full 30 Watts on All Ports

9 Kyland-USA, Kansas City, MO What is PoE? Power over Ethernet allows Ethernet networked user devices to be powered over the same 4-pair UTP that provides the network signal Power is 48 volt DC, up to 25.5 Watts at the Powered Device (PD) as per the new 802.3at standard Compatible with all networks, up to Gigabit Ethernet which uses all four pairs for transmission

10 Kyland-USA, Kansas City, MO PoE (Power Over Ethernet) Power over Ethernet is a mechanism for supplying power to network devices over the same cabling used to carry network traffic. PoE allows devices that require power, called Powered Devices (PDs),such as IP telephones, wireless LAN Access Points, and network cameras to receive power in addition to data, over existing infrastructure without needing to upgrade it. This feature can simplify network installation and maintenance by using the switch as a central power source for other network devices. POE Ethernet Switch is commonly called: PSE (Power Sourcing Equipment)

11 Kyland-USA, Kansas City, MO The Advantages of PoE Some of the advantages of PoE include: A single cable between switch and Powered Device (PD) No separate power installation/ connection needed for PD's Simplified installation and space saving Device placement is not limited to nearby power sources PD's can be easily moved to wherever there is LAN cabling Safety - no mains or primary voltages anywhere A UPS can guarantee power to devices even during power failure Devices can be shut down or reset remotely Little configuration or management required

12 Kyland-USA, Kansas City, MO PoE Devices VoIP phones Wireless access points Remote Sensors Digital clocks Webcams Security Cameras, including PTZ Intercoms Building Access systems Wimax Radios Plus others…

13 Kyland-USA, Kansas City, MO Current PoE Standards The PoE IEEE 802.3af IEEE Standard Approved June 2003. 802.3af Standard Specifes 15.4 Watts (PSE) with 12.95 Watts (PD), delivered at 100 Meters The PoE IEEE 802.3at IEEE Standard Approved 2009. 802.3at Standard Specifes 34.2 Watts (PSE) with 25.50 Watts (PD), delivered at 100 Meters

14 Kyland-USA, Kansas City, MO PoE 802.3 af/at Comparison Table Property802.3af (802.3at Type 1)802.3at Type 2 Power available at PD (DELIVERED POWER) 12.95 Watts25.50 Watts Maximum power delivered by PSE (LAUNCH POWER) 15.40 Watts34.20 Watts Voltage range (at PSE)44.0–57.0 Volts DC50.0–57.0 Volts DC Voltage range (at PD)37.0–57.0 Volts DC42.5–57.0 Volts DC Maximum Current (Power)350 mA (milliamps)600 mA per mode (milliamps) Maximum Cable Resistance20 Ω (Category 3) (Ohms)12.5 Ω (Category 5) (Ohms) Power Management Three power class levels negotiated at initial connection Four power class levels negotiated at initial connection or 0.1 W steps negotiated continuously De-rating of maximum cable ambient operating temperature None5°C with one mode (two pairs) active Supported cablingCategory 3 & Category 5 / 5E / 6 Category 5 / 5E / 6 (Gigabit Rated Cable) Supported modes Mode A (endspan), Mode B (midspan) Mode A, Mode B

15 Kyland-USA, Kansas City, MO How PoE Works? PoE requires little configuration or management. The PSE automatically determines whether a device connected to a port is a powered device or not, and can determine the power class of the device. The PSE can supply up to 25.5 watts of power (at 48 Volts) to the PD device, while at the same time providing standard Ethernet network connectivity.

16 Kyland-USA, Kansas City, MO Power Device (PD) Discovery The first step for PSE equipment (an Ethernet switch for example) is to ascertain whether a device plugged into a port is a valid Powered Device (PD). No power is sent down the cable until a signature check is completed. The IEEE 802.3at / af standard for device detection involves applying a DC voltage between the transmit and receive wire pairs, and measuring the received current. A PSE will expect to see approximately 25K Ohm resistance and 150nF capacitance between the pairs for the device to be considered a valid PD. A range around these values is specified in the IEEE 802.3ad standard. The PSE will check for the presence of PD's on connected ports at regular intervals, so power is removed when a PD is no longer connected.

17 Kyland-USA, Kansas City, MO Power Classification- Discovery Once a PD is discovered, a PSE may optionally perform PD classification by applying a DC voltage and current to the port. If the PD supports an optional power classification it will then apply a load to the line to indicate to the PSE the classification the device requires. Any unclassified PD is considered to be a class 0 device. The IEEE 802.3at standard supports delivery of up to 25.50 Watts per port (at the PD) that may be used to deliver power to PoE devices. The maximum power consumed by a PD, as specified by the standard, is 25.50 Watts. The PSE (POE Switch Port) provides the 'extra' power (up to 34.2 watts) to compensate for line loss through the copper (resistance). This factor is calculated on a maximum cable length of 100 Meters

18 Kyland-USA, Kansas City, MO Power Sent Through The Data Cable An Ethernet cable (CAT5 / 5E / 6) has four twisted pairs (8wires), but only two of these are used for data transfer under the 802.3af standard. The spare pairs are used. In this case the unused pairs are used to transfer the power. The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power to the centre tap of the isolation transformer without upsetting the data transfer. The IEEE 802.3af standard did not allow both sets of wires to be used, the new 802.3at standard allows their use. Different vendors PSE equipment may use one or other of the methods to supply power depending upon the PoE engineering design. So the PSE applies power to either the spare wires, data wires or both. The PoweredDevice (PD) must be able to accept power from every option depending upon the class of the device. The voltage supplied is nominally 48V, and a maximum of 25.50 Watts of power is available at the Powered Device. (PD) An isolated DC-DC converter transforms the 48V to a lower voltage more suitable for the electronics in the Powered Device.

19 Kyland-USA, Kansas City, MO ClassUsage Classification current [mA] Power Range [Watt] Class Description 0Default0–40.44–12.94 Classification unimplement ed 1Optional9–120.44–3.84 Very Low power 2Optional17–203.84–6.49Low power 3Optional26–306.49–12.95Mid power 4 Valid for 802.3at (Type 2) devices, not allowed for 802.3af devices 36–4412.95–25.50High power Power Levels Available POE POWER LEVELS

20 Kyland-USA, Kansas City, MO Stages of Powering Up a PoE Link StageAction Volts specified [V] 802.3af 802.3at Detection PSE detects if the PD has the correct signature resistance of 19–26.5 kΩ (BOTH) 2.7–10.0 Classification PSE detects resistance indicating power range (BOTH) 14.5–20.5 Mark 1 Signals PSE is 802.3at capable. PD presents a 0.25–4 mA load. —7–10 Class 2 PSE outputs classification voltage again to indicate 802.3at capability —14.5–20.5 Mark 2 Signals PSE is 802.3at capable. PD presents a 0.25–4 mA load. —7–10 Startup Startup voltage> 42 Normal operation Supply power to device37–5742.5–57

21 Kyland-USA, Kansas City, MO PoE vs. Power Supplied Locally at Device Reduced cabling costs. Adding power circuits at the point of need can be a significant expense, This way one cable provides both power and data. Cameras and access points & sensors can be moved and wired easily. Reliability associated centralized supplied power. Circuit outage at a desk will take out a VOIP set powered locally. Using uninterruptible power supplies (UPS), Voice over IP (VoIP) telephones can now be deployed without worrying about them not functioning during a power outage.

22 Kyland-USA, Kansas City, MO Product Offerings: (POE Managed) KY-2402GCP+ : 28 Port -30 Watt (802.3at) Managed Power Over Ethernet Gigabit Switch 24 PSE 10/100/100-BaseT(X) Copper Ports and 4 SFP 1000Base(X) Sockets, CYBER- SECURE Video Automatic – Silicon Based DOS/DDOS Protection, Automatic Camera Restart AC Power Supply: 110-220 Volts AC / 50-60Hz (With 802.3az – Green Scheduling) KY-8PSE30WMH -12 Port -30 Watt (802.3at) Managed Power Over Ethernet Gigabit Switch 8 PSE 10/100/100-BaseT(X) Copper Ports and 4 SFP 1000Base(X) Sockets, CYBER- SECURE Video Automatic – Silicon Based DOS/DDOS Protection, Automatic Camera Restart AC Power Supply: 110-220 Volts AC / 50-60Hz (With 802.3az – Green Scheduling) KY-8PES30WM -12 Port -30 Watt (802.3at) Managed Power Over Ethernet Gigabit Switch 8 PSE 10/100/100-BaseT(X) Copper Ports and 4 SFP 1000Base(X) Sockets, CYBER- SECURE Video Automatic – Silicon Based DOS/DDOS Protection, Automatic Camera Restart AC Power Supply: 110-220 Volts AC / 50-60Hz (With 802.3az – Green Scheduling)

23 Kyland-USA, Kansas City, MO Product Offerings: (POE UN- Managed) KY-24PSE30WU -28 Port -30 Watt (802.3at) Managed Power Over Ethernet Gigabit Switch 24 PSE 10/100/100-BaseT(X) Copper Ports and 4 SFP 1000Base(X) Sockets, CYBER- SECURE Video AC Power Supply: 110-220 Volts AC / 50-60Hz / Rack Mount KY-16PSE30WU -20 Port -30 Watt (802.3at) Managed Power Over Ethernet Gigabit Switch 16 PSE 10/100/100-BaseT(X) Copper Ports and 4 SFP 1000Base(X) Sockets, CYBER- SECURE Video AC Power Supply: 110-220 Volts AC / 50-60Hz / Rack Mount KY-8PSE30WU -12 Port -30 Watt (802.3at) Managed Power Over Ethernet Gigabit Switch 8 PSE 10/100/100-BaseT(X) Copper Ports and 4 SFP 1000Base(X) Sockets, CYBER- SECURE Video Requires External 50-57vdc / 300 Watt Power Supply / Din Rail or Rack Mount KY-4PSE30WU -4 Port -30 Watt (802.3at) Managed Power Over Ethernet Gigabit Switch 4 PSE 10/100/100-BaseT(X) Copper Ports, CYBER-SECURE Video Requires External 50-57vdc / 150 Watt Power Supply / Din Rail or Rack Mount

24 Kyland-USA, Kansas City, MO POE Switches with CYBER-SECURE Video & 802.3az (Green Scheduling)

25 Kyland-USA, Kansas City, MO KY-HI8042F POE+, Solar Certified,HD Camera Ready! Un-Managed POE+, 4 Port, Gigabit, Solar Series Industrial Ethernet Switch A. Hardware Features Complies with IEEE 802.3at (af)/ IGMPv1,2 & 3 Plug & Play - Ready Out of the Box Operation POE+ / 30 Watts available – ALL Ports – All the Time Supports Flow Control / 8K MAC address table 20 Gbps Switching Fabric / Supports Jumbo Frames Cyber Secure Video / Clean Code Technology HD Video Camera Ready / Plug and Play B. Industrial Conformance DC Voltage: with Over Load Current Protection 12, 24, or 48 Volts DC Input Ultra Low Power / <126.5 Watts Full Power Consumption - Port & Power Supply Spike Protection -40 ~ 85 Degree C // -40 ~ 185 Degree F Rack Mount / IP-40 Aluminum case EMI: FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 Safety: UL, cUL, CE/EN60950, NEMA TS-2 Stability testing with IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock) and IEC60068-2-6 (Vibration), NEMA KY-HI8042F 4 X 10/100/1000Base(T)X PSE - 30 Watt (POE+) RJ45 Ethernet ports, 1 X 10/100/1000Base(X) SFP/RJ45 Combo & 1 X 100/1000 Base(X) SFP Ports IndustrialAC PowerIGMPv1, 2, & 3 Cyber Secure Video Clean Code Technology Flow Control Certified Cisco Replacement

26 Kyland-USA, Kansas City, MO What You Need to Know /1 There is a Launch and a Receive Power Level Power is sent as 48 volts DC (Direct Current) Data and Power travel the same wire pairs POE works to a maximum length of 100 Meters KUSA PoE has CYBER-SECURE VIDEO (CSV) KUSA has Managed & Unmanaged PSE switches PD‘s must be 802.3at / af compliant The CATegory of wire MUST be observed Category 3 wire will NOT support Gigabit links

27 Kyland-USA, Kansas City, MO What You Need to Know / 2 Managed POE Switches have 802.3 Green Scheduling (Automatic Restart / Keep Alive Check Clean Code Technology (Protects from Viruses / BOTS Automatic Protection (in silicon) from Denial of Service & Distributed Denial of Service Attacks (No operator Intervention Required IP Policing and Port Shutdown based on IP / MAC Address 5 Year Warranty / Temperature Hardened / Fanless

28 Kyland-USA, Kansas City, MO Kyland-USA Engineering & Sales Support Telephone: (816) 988-7861 Email: Sales@Kyland-USA.com FAX: (480) 287-8605 Web Site: www.Kyland-USA.com Kyland-USA is a Veteran Owned Small Business (VOSB)

29 Kyland-USA, Kansas City, MO DYMEC Engineering & Sales Support Telephone: (816) 988-7861 Email: Sales@DYMEC.com FAX: (480) 287-8605 Web Site: www.DYMEC.com DYMEC Industrial Engineering

30 Kyland-USA, Kansas City, MO DYMEC is a registered trademark of Kyland-USA THANK YOU !


Download ppt "Kyland-USA, Kansas City, MO DYMEC is a registered trademark of Kyland-USA."

Similar presentations


Ads by Google