Presentation is loading. Please wait.

Presentation is loading. Please wait.

NEMO - NEutrino Mediterranean Observatory

Similar presentations


Presentation on theme: "NEMO - NEutrino Mediterranean Observatory"— Presentation transcript:

1 NEMO - NEutrino Mediterranean Observatory
A R C H I T E C T S O F A N I N T E R N E T W O R L D Author: D’Antonio Claudio All rights reserved © 2001, Alcatel

2 _____________________________________________
Presentation This presentation to summarize the project as shown during the INFN engineers visit in Alcatel premises on 14-15th of June 2001. _____________________________________________ With this system will be possible to set up 1024 STM-1 bi-directional SNCP protected paths. With the NMS will be possible to monitor alarms, to perform remote commands and to set up the necessary paths and protection. Service Provisioning: interface functions to allow SML to perform Service Delivery. Service Charging&Billing, Service Assurance Note: depending on “pitch” of presentation, a deeper analysis of this may be presented using confidential slide on management architecture of multi-technology service network Single interface: all functions described are provided using the same interface (hereafter called Isn) Single point: SML connects to NML at one point only; (within NML, Isn request is translated and distributed as appropriate to the relevant NML/EML/NEs) Multi-technology interface: to manage new technologies as well as existing ones in an integrated way, and so cater for - SDH/PDH transport network - ATM network - IP network - Access network Presentation, June 15th 01, page n° 2  » All rights reserved © 2001, Alcatel

3 1660SM (STM-4/16 Node Equipment) 1686WM (32 DWDM Equipment)
Alcatel Equipment Alcatel Equipment: Transmission: 1660SM (STM-4/16 Node Equipment) 1686WM (32 DWDM Equipment) Network Management System: 1353SH (Element Manager Layer) 1354RM (Network Manager Layer) Presentation, June 15th 01, page n° 3  » All rights reserved © 2001, Alcatel

4 All common cards are protected EPS 1+1.
1660SM Each 1660SM will be equipped with 16 Optical STM-1 tributary to the tower that will be protected with EPS N+1 and 2 Optical STM-16 (Colored) interfaces to the DWDM systems for the SNCP protection. All common cards are protected EPS 1+1. Subrack Size = 482W x 250D x 650H mm Consume = 211W (if equipped with 16xSTM-1 + 2xSTM-16) Presentation, June 15th 01, page n° 4  » All rights reserved © 2001, Alcatel

5 1660SM - Optical STM-1 module
This Optical Module (S-1.1) will be used as Electrical/Optical converter within the customer equipment in both sides, under sea and in the landing station. Consume = 1,5 W One module for each floor of the tower. receiver in the landing station. Presentation, June 15th 01, page n° 5  » All rights reserved © 2001, Alcatel

6 1686WM These equipment are used to concentrate 16xSTM-16 channel to one lambda. 4x1686WM are necessary to carry the main traffic and other four to carry the protection. A booster +14/+17dB will be necessary depending on the real length of the submarine cable. Subrack Size = 482W x 250D x 400H mm Consume = 90W (if equipped with 16 and a +14dB booster) Presentation, June 15th 01, page n° 6  » All rights reserved © 2001, Alcatel

7 Network Management System
1353SH: EML - Element Manager Layer Alarms on HW Maintenance Memory Log. Files Management Laser Management Remote Commands (Loopback/Restart) Synchronization Management Software download for future upgrade Performance Monitoring FAD (Functional Access Domain) - User Profiles 1354RM: NML - Network Manager Layer Network Management Set up Paths Alarms on Paths Remote Commands (Loopback on paths) Performance Monitoring on single path 1353SH 1354RM Each equipment can be the GNE (Gateway Network Element); through this equipment it is possible to monitor the entire network. To the Network Terminals Server Remote Support from ALCATEL if needed. Presentation, June 15th 01, page n° 7  » All rights reserved © 2001, Alcatel

8 Two kind of protection are available at the same time:
Network Protection: SNCP This kind of protection works at Paths level in a ring based topology as follow: Equipment Protection: EPS 1+1 This kind of protection works within the equipment as follow: Two kind of protection are available at the same time: SNCP (Network Protection) EPS 1+1 (Equipment Protection) Main Spare TX Side RX Side Main Spare Presentation, June 15th 01, page n° 8  » All rights reserved © 2001, Alcatel

9 SNCP Protection Scheme
Main Spare 1660SM 1686WM 100 Km. STM-1 SEA LAND Ring Structure Presentation, June 15th 01, page n° 9  » All rights reserved © 2001, Alcatel

10 Multiplex Structure Note:
64 48 32 17 18 19 20 21 22 23 24 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 16xSTM-1 64xSTM-16 Spare 64xSTM-16 Main 57 58 59 60 61 62 63 1660SM 1686WM Note: 1024 STM-1 to be carried with SNCP protection. Both sides (under Sea and Landing station) have to be considered as equally for the Multiplex Structure point of view. Presentation, June 15th 01, page n° 10  » All rights reserved © 2001, Alcatel

11 Under Sea - 1660SM 8x8=64 Towers 16xSTM-1 STM-16 Main STM-16 Spare
2 3 16 16xSTM-1 STM-16 Main STM-16 Spare Under Sea SM Presentation, June 15th 01, page n° 11  » All rights reserved © 2001, Alcatel

12 Under Sea - 1686WM Under Sea - 1686WM 8 Junction Boxes:
8x1686WM - 4 for Main traffic - 4 for Spare traffic 16  each 16xSTM-16 Spare 16xSTM-16 Main 100 Km submarine cable 48 fibers available: 8x1686WM - 2 fiber each 16 needed for transmission 32 fibers free To Land Presentation, June 15th 01, page n° 12  » All rights reserved © 2001, Alcatel

13 Landing Station Landing Station From Sea 1024xSTM-1 8x1686WM 64x1660SM
NMS Presentation, June 15th 01, page n° 13  » All rights reserved © 2001, Alcatel

14 Equipment needed to complete this project: Under Sea:
Summary Equipment needed to complete this project: Under Sea: 64x1660SM (each equipped with 16xSTM-1 and 2xSTM-16) 8x1686WM (16  each) 1024 Optical S-1.1 modules. Landing Station: NMS (1x1353SH + 1x1354RM) based on HP server. Presentation, June 15th 01, page n° 14  » All rights reserved © 2001, Alcatel

15 Elenco degli strumenti necessari per effettuare i test di "Line Up &
Commissioning" per gli apparati di tipo 1686WM e 1660SM. << 1686WM - Typical Instruments >> - Optical Power Meter (OPM) dBm - Optical Spectrum Analyzer (OSA) WDM Features, ITU-T G.692 Channel Spacing - PDH/SDH Analyzer STM-1 / STM-4 / STM-16 Optical Interface - Multi laser Generator ITU-T G.692 Channel Spacing - Variable optical attenuator ¸40 dB attenuation - N.2 x 1/16 Optical Splitter - 1/ 2 Optical Splitter - Data Tester Tx rate up to 64 Kbit/s contra-directional CCITT interface V11 - Digital Multimeter << 1660SM - Typical Instruments >> - PDH/SDH Analyzer ( Mb/s - STM-1,4,16) - Optical power tester (radiometer) nd and 3rd window - Single-mode variable optical attenuator Variable attenuator within the 0-50dB, 2nd and 3rd window - Digital multimeter - Frequency counter MHz ± 1 Hz Presentation, June 15th 01, page n° 15  » All rights reserved © 2001, Alcatel

16 Presentation, June 15th 01, page n° 16 »
<< Craft Terminal >> È necessario dotarsi di un PC portatile con le seguenti caratteristiche: < Hardware Configuration > - CPU Pentium II 200 MHz - RAM MB - HARD DISK GB (4 GB suggested) - MONITOR " (14" suggested) - RESOLUTION x 768 pixel - CD-Rom drive - Ethernet port - 3" * floppy disk drive (1.44 MB) - It is suggested to have a Printer (serial or parallel accepted by WINDOWS). < Software items required > - WINDOWS NT v. 4.0 Services Package 3 (Copyright Microsoft Corporation) already installed. - Sun Microsystems Java JRE 1.2 - Netscape Communicator 4.x or Internet Explorer 4.x << Accessori >> - Craft Terminal cable PC connector (F interface) - Optical patch-cord Terminations dependent on unit/ODF connectors, radiometer and attenuator - Coaxial Cables Terminations dependent on instrument and equipment side - Cables for synchronism - Synchronism termination (120 or 75 ohm) - Optical Fiber cleaning set Da notare che molti strumenti come il PDH/SDH Analyzer, il Multimetro, il Data Tester, il PC ecc... sono strumenti comuni per entrambi i tipi di apparati. Presentation, June 15th 01, page n° 16  » All rights reserved © 2001, Alcatel

17 Author: D’Antonio Claudio All rights reserved © 2001, Alcatel
A R C H I T E C T S O F A N I N T E R N E T W O R L D Author: D’Antonio Claudio All rights reserved © 2001, Alcatel


Download ppt "NEMO - NEutrino Mediterranean Observatory"

Similar presentations


Ads by Google