Presentation is loading. Please wait.

Presentation is loading. Please wait.

Laboratoire de l’Accélérateur Linéaire (IN2P3-CNRS et Université Paris-Sud 11), Orsay, France Olivier Callot 21 September 2005 Calorimeter Configuration.

Similar presentations


Presentation on theme: "Laboratoire de l’Accélérateur Linéaire (IN2P3-CNRS et Université Paris-Sud 11), Orsay, France Olivier Callot 21 September 2005 Calorimeter Configuration."— Presentation transcript:

1 Laboratoire de l’Accélérateur Linéaire (IN2P3-CNRS et Université Paris-Sud 11), Orsay, France Olivier Callot 21 September 2005 Calorimeter Configuration DB Calorimeter configuration Test systems Expected needs

2 Olivier Callot 21 September 2005Calorimeter configuration DB2 Preamble  I had very little time to prepare this talk I’m moving to a new house next week, and I’m fully busy painting, wall-papering,… The content is then just a brain dump No time for discussion in the group, sorry.  Apologies if things are wrong/incomplete  I should have followed the whole workshop The commissioning is very interested by this DB But I have no time these days…

3 Olivier Callot 21 September 2005Calorimeter configuration DB3 Calorimeter system  The calorimeter has 4 detectors and 3 readout Parts in common, parts are different  ECAL + HCAL Same PMTs, same FE cards, different test systems, LED and radioactive source (6000 + 1500) HV, gain, delay, … To be loaded in the hardware Each FE card has many configuration parameters Operation mode, pedestal mode, … And part of the configuration is for the L0 trigger  Gain, connected neighbours,…

4 Olivier Callot 21 September 2005Calorimeter configuration DB4  Prs + SPD Single FE card, but two independent detectors Similar very-front-end: Two ‘half channels’ alternate between integration and reset at each BX. This gives two pedestals, two thresholds,… SPD is only digital Thresholds loaded on VFE board Threshold calibration mode difficult, as we can only get the fraction over threshold, not the signal shape… Prs is analogue 10 bits ADC, plus a trigger bit derived from the ADC value Single HV for 64 channels For Prs and SPD, they use the same tubes

5 Olivier Callot 21 September 2005Calorimeter configuration DB5 Test systems  Internal FE card tests Inject test patterns (loaded in a FIFO on each FE board channel) Read the answer by another FIFO, usually in the CROC Very useful to test the L0 Calo connections  LED tests Same interface to configure (pulse height, delay) the LED But different grouping One LED lights one (SPD/PRS) or many (9, 16, ?) PMTS Pattern of fired LED pre-loaded in a table  Not all LED in every event !  Each LED event uses a new entry in the table PIN diode to monitor the LED Readout using dedicated FE cards (ECAL,.HCAL)

6 Olivier Callot 21 September 2005Calorimeter configuration DB6

7 Olivier Callot 21 September 2005Calorimeter configuration DB7 Expected needs  HV control 6000 + 1500 + 100 + 100 HV, Cocroft-Walton type 7700 values, only one configuration per PMT No intermediate step in ramping the HV, either ON or OFF.  LED control Around 1000 channels (should check this number), with amplitude and delay Plus tables of pattern to load, 32 x 32 bits for 32 channels.  FE card Delay and gain ECAL + HCAL* 7500 Delay + threshold Prs* 6000 ThresholdSPD* 6000

8 Olivier Callot 21 September 2005Calorimeter configuration DB8  Global FE cards parameters A few per card = 188 + 50 +100 cards  Trigger parameters Gain and Threshold are for trigger Connections, Validation card LUTs Should be covered by Renaud in a few minutes  TELL1 boards No longer any calibration nor ID generation Almost no parameters, except a list of valid input fibres.

9 Olivier Callot 21 September 2005Calorimeter configuration DB9 Unclear points  Populating the database Entering several thousands numbers is not realistic Most of them are obtained from another program Who writes to the database ? Integrity, restore to previous version, …  Partitioning and partial readout How to work with only part of the detector Mainly used during commissioning next year Mainly affects the trigger: Which neighbours to ignore,…  Timescale for first use We should bring electronics next spring, HV and LED are there Almost…


Download ppt "Laboratoire de l’Accélérateur Linéaire (IN2P3-CNRS et Université Paris-Sud 11), Orsay, France Olivier Callot 21 September 2005 Calorimeter Configuration."

Similar presentations


Ads by Google