Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up.

Similar presentations


Presentation on theme: "1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up."— Presentation transcript:

1 1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up etc.

2 2 Luca Stanco - INFN Padova Elettrons Protons RMUON BMUON

3 3 Luca Stanco - INFN Padova ~ 3 600 LSTs (with lenght from 0.7 to 10.2 m) ~ 43 000 8-bit analog channels ~ 29 000 digital channels Area detector > 2 000 m 2 Technical Coordinator: Riccardo Brugnera Web-master: Vincenzo Chiochia Resolution: 1 mm in the strip view 3 mm in the wire view

4 4 Luca Stanco - INFN Padova Mortality... plus ~ 68 LST in trip for 10-40% of time plus ~ 10 LST in trip for 10-40% of time

5 5 Luca Stanco - INFN Padova Dead LST normally switched off Dead LST s are normally switched off Simulation in the Monte Carlo via an EAZE job: via an EAZE job: efficiency to evaluate efficiency dependence (small effect: 5%) efficiency BMUON RMUON - MC ideal - - MC with dead LST

6 6 Luca Stanco - INFN Padova Slot 8: Elastic BMUON Slot 10: Inner BMUON RMUON Slot 11: Inner RMUON BMUON Slot 14: Outer BMUON RMUON Slot 15: Outer RMUON GLOMU GLOEXO Inner Outer

7 7 Luca Stanco - INFN Padova rates... 1 b for L = 10*10 30 10 Hz (most of the runs)

8 8 Luca Stanco - INFN Padova with INNER chambers and with ISOMU: Calorimeter regions

9 9 Luca Stanco - INFN Padova rates INNER OUTER

10 10 Luca Stanco - INFN Padova GLOMU rates 30 nb for L = 10*10 30 0.03 Hz cosmics

11 11 Luca Stanco - INFN Padova independent setup: efficiency vs HV working value to reduce trips

12 12 Luca Stanco - INFN Padova HV: 4700 HV: 4550 include inefficiency factor on single LSTin the Monte Carlo (15%) 100% 88% 75%

13 13 Luca Stanco - INFN Padova - MC ideal - - MC with dead LST and 15% factor for HV efficiency BMUON RMUON 15% inefficiency coherent with analysis of single track segment !

14 14 Luca Stanco - INFN Padova efficiencyDATA Check efficiency with DATA themselves ! Two independent analysis on 2 track + - clean events (3 different set of events, depending of the trigger) BMUON SET 1 SET 2

15 15 Luca Stanco - INFN Padova … much more in Alessandro Bertolin talk this afternoon Monte Carlo is off of an overall factor ! A few investigations performed. Not yet found out the reason...

16 16 Luca Stanco - INFN Padova VMS computer for DAQ patch from DEC (and spare VAX from DELPHI available) upgrade on going... Slow Control with OS9 (version 2.3 NOT good) manual patch (bring time back, uff !) … upgrade to 3.03 ?

17 17 Luca Stanco - INFN Padova AbortingRun Time for Aborting as function of Run... problem while Aborting Run ?

18 18 Luca Stanco - INFN Padova Aborting Distribution of Time for Aborting... for last positron runs...

19 19 Luca Stanco - INFN Padova Good general behaviour of the detector Triggers under control Efficiency studies on the way on Few upgrades needed for next millenium Good perspectives for next millenium Runs


Download ppt "1 Luca Stanco - INFN Padova Krakow, 28 September 1999 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up."

Similar presentations


Ads by Google