Presentation is loading. Please wait.

Presentation is loading. Please wait.

MIS 1.5 Hardware Overview.

Similar presentations


Presentation on theme: "MIS 1.5 Hardware Overview."— Presentation transcript:

1 MIS 1.5 Hardware Overview

2 MIS Chassis Includes: JBOD rear features 4 HD miniSAS, one NIC, and one serial port Front bezel with control panel buttons and indicator LEDs Case with bifurcated top covers for front and rear access Rear access to power supplies, server modules, KVM ports, and all cabling

3 Chassis Interior Chassis Exterior SAS Midplane Bridge Midplane
Fan Module Midspan Brace Chassis Intrusion Detector Front Grille and S9D Interface Port StorBrick Drive Bays Boot Drive Module Bridge Midplane Fan Baseboard Fan Mounting Bracket StorBrick Baseboard SAS Midplane Power Supply Bridge Server Module (single server) Power Supply Module s

4 StorBrick Layout Dual Server Only JBOD Only

5 SAS Interior Cabling HBA to SAS Interposer SAS Midplane to StorBricks
Dual Server SAS Midplane to StorBricks Single Server

6 Server Module Components
Single Server Module Shown SAS Interposers Motherboard Flexible Shielding Heat Sinks Air Duct Memory DIMMs Internal SAS HBAs CPU 2 Riser 3 Bridge Board Memory DIMMs Battery Backup Unit Mounting Plate Battery Backup Units CPU 1 External HBAs Riser 1 External HBAs Single Servers have taller risers allowing for 2 additional HBAs (total 6). Dual Server Module HBAs are half-height (2.12” by 3.375”), with a maximum of 4 HBAs per server module (2 internal & 2 internal or external). Riser 2 Module Case Remote Management Console Component (RMM4Lite)

7 Customer Replaceable Units (CRUs)
MIS 1.0 CRUs Fans Power Supplies Drives External Cables Front Bezel Rails & external air ducts MIS 1.5 CRUs All 1.0 CRUs Battery Backup Units* HBAs & PCIe cards* Risers* DIMMs* JBOD I/O Modules* * Version -002 August 2013

8 System Interfaces Front Control Panel and LEDs display status and give power control (chassis ID, on/off/reboot). NMI Reset Button not supported (it does nothing). BMC Web-based interface on server platforms allows for hardware monitoring, alerts, and remote management. alerts require configuration & connection to a mail (SMTP) server. Java Runtime Environment 6 (or later) required for remote desktop. The Web-based Fan Base Service Page lets customers set fans in a “Safe to Service” mode for replacing fan modules (otherwise emergency shut-down starts after 10 seconds). MegaRAID Storage Manager monitors capacity drives and RAID processes (mirrors, rebuilds, etc.). The command-line interface CLI Zoning tool (not shown) also has options to view & change drive power status.


Download ppt "MIS 1.5 Hardware Overview."

Similar presentations


Ads by Google