Presentation is loading. Please wait.

Presentation is loading. Please wait.

Paul Sellin Detector Research at the University of Surrey Dr Paul Sellin Centre for Nuclear and Radiation Physics Department of Physics University of Surrey,

Similar presentations


Presentation on theme: "Paul Sellin Detector Research at the University of Surrey Dr Paul Sellin Centre for Nuclear and Radiation Physics Department of Physics University of Surrey,"— Presentation transcript:

1 Paul Sellin Detector Research at the University of Surrey Dr Paul Sellin Centre for Nuclear and Radiation Physics Department of Physics University of Surrey, Guildford

2 Paul Sellin CdTe/CdZnTe are the most mature high-Z bulk materials for X-ray and gamma ray detectors: High-Z materials for room temperature gamma ray detectors single crystal HgI 2  CdTe and CdZnTe offer good spectroscopic performance for X-rays and gammas  For higher photon energies very high-Z materials such as mercuiric iodide (HgI 2 ) are actively being developed www.realtimeradiography.com

3 Paul Sellin Cadmium Zinc Telluride for X-ray/gamma spectroscopy CdZnTe material quality has improved recently, with various new suppliers in the US/Canada, Europe and Japan:  wafers of large single-crystal areas are available, with excellent charge transport  High resistivity  =3x10 11  cm, and  e =1.8x10 -2 cm 2 /V 4x4 pixellated devices have shown very good resolution  1.35% FWHM at 662 keV

4 Paul Sellin ‘Hexitec’ Basic Technology project Surrey is one of the major members of the recent Hexitec Basic Technology project – a £3M 4 year project Project aim – development of CdZnTe pixel detectors for X-ray imaging  Manchester – detector applications  Durham – CdZnTe material growth  Surrey – Material and detector characterisation and prototyping  CCLRC RAL – Pixel detector fabrication

5 Paul Sellin Synthetic diamond for detector applications Single-crystal natural diamonds have been studied in the past for detector applications – excellent electronic properties are seen in a tiny number of gem stones. P. Bergonzo et al, Dia Rel Mat 10 (2001) 631-638

6 Paul Sellin Single-crystal CVD diamond detectors Specialist applications of diamond detectors:  as tissue-equivalent rad-hard detectors, eg megavoltage therapy beams, neutrons  detectors for very high temperature, high radiation environments True single-crystal material removes charge trapping associated with grain boundaries:  100% CCE demonstrated from alpha particles  Extreme radiation hardness  High mobility  very fast signals (~10ps timing resolution) silicon detector diamond detector Ref: M. Pomorski et al, phys stat sol a 203 (2006) 3152-3160

7 Paul Sellin Semiconducting polymer – a new radiation detector material? Various candidate semiconducting polymers are of interest for radiation detection applications, eg:  Poly-acetylene  PPV (poly-phenylene-vinylene) These materials have the following properties:  A ‘band gap’ energy low enough to give semiconducting properties (eg. ~1.5 eV)  High resistivity combined with reasonable charge transport:  Electron and hole mobilities are low  Carrier concentrations are low (<10 14 cm -3 )  good depletion thickness  Sufficient radiation hardness Potential Benefits:  large area, low cost sensor technology  fabrication onto flexible, complex geometry, substrates  tissue equivalent for dosimetry applications

8 Paul Sellin X-ray response from the PFO detector X-ray response photocurrent was measured from the PFO device for dose rates up to 18.5 mGy/s Photocurrent vs bias voltage shows an approximately linear increase Dark current is ~0.8 nA @ -50V Photocurrent vs dose rate gives the detector sensitivity. For a 10  m thick device: ~0.06 nC/mGy @ -10V ~0.24 nC/mGy @ -50V X-ray Dose Rate (mGy/s)

9 Paul Sellin Other plastic dosimetry materials Various organic and plastic bulk materials have been investigated since Fowler’s work in the 1950’s Early measurements investigated X-ray induced photocurrents, and showed long time transients Recent data at Surrey on newer material have studied dosimetry response of thick (~mm) plastic layers to 50 kV X-rays:  signal-background ratio of ~500x  ‘fast’ X-ray response of <100 ms

10 Paul Sellin New MSc course in Radiation Detection and Instrumentation A new MSc programme for September 2008 – exploring the operation, characterisation and development of radiation detectors and instrumentation Application areas will include medical physics, dosimetry, particle physics, synchrotrons, space science and homeland security Core programme modules:  Radiation Physics and Laboratories  Radiation Measurement  Detector Instrumentation  Interfacing and Signal Processing  Imaging and Remote Sensing Applications modules:  Particle Physics Detector Technology  Astronomy Detector Technology  Radiation Protection  Medical applications of Ionising Radiation www.ph.surrey.ac.uk/msc/rdi


Download ppt "Paul Sellin Detector Research at the University of Surrey Dr Paul Sellin Centre for Nuclear and Radiation Physics Department of Physics University of Surrey,"

Similar presentations


Ads by Google