Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 CALICE D4 simulation results G.Villani feb. 06 Cell size: 25 x 25  m 2 Epitaxial thickness: 20  m Diode location: S4 Diode size: 1.5 x 1.5  m 2 Cell.

Similar presentations


Presentation on theme: "1 CALICE D4 simulation results G.Villani feb. 06 Cell size: 25 x 25  m 2 Epitaxial thickness: 20  m Diode location: S4 Diode size: 1.5 x 1.5  m 2 Cell."— Presentation transcript:

1 1 CALICE D4 simulation results G.Villani feb. 06 Cell size: 25 x 25  m 2 Epitaxial thickness: 20  m Diode location: S4 Diode size: 1.5 x 1.5  m 2 Cell 2Cell 3 Cell 4 Cell 5 Cell 6 Cell 9 Cell 8 Cell 7 12 3 4 Cell 1 Diode bias: 2VPWell bias: 0V Substrate bias: floating 10 hits simulated: mirroring over central cell and transformation over 3 x 3 cells allows surface reconstruction of Q coll (x,y) Cell := enclosing of 4 diodes whose Charge add (as in cell 5)

2 2 CALICE D4 simulation results G.Villani feb. 06 thickness singlemulti 15  m 20  m

3 3 Surface Q coll (x,y) Normalized surface Q coll (x,y) vs. max(Qcoll(x,y)) CALICE D4 simulation results G.Villani feb. 06 41015 104 2643422510 15441051064315 441051064415 102644 2610 4 15 104 5011649 118422118 5111850 Single diode Q coll (x,y) hit 1 Sum diode Q coll (x,y) hit 1 Epitaxial thickness: 20 μm Q coll (x,y) = 1092

4 4 Contour plot of cell charge at different % of total collected charge 20% 40% 60% 80% Increasing number of threshold levels reduces spatial error Minimum error around ≈ 57 % ( need further analysis) Normalized surface Q coll (x,y) vs. max(Qcoll(x,y)) CALICE D4 simulation results G.Villani feb. 06 Epitaxial thickness: 20 μm

5 5 Surface Q coll (x,y) Normalized surface Q coll (x,y) vs. max(Qcoll(x,y)) CALICE D4 simulation results G.Villani feb. 06 491719107 92445 259 14411151194414 411101134314 82340 309 382318105 4612651 110457115 4312153 Single diode Q coll (x,y) hit 1 Sum diode Q coll (x,y) hit 1 Epitaxial thickness: 15 μm Surface Q coll (x,y) Q coll (x,y) = 1122

6 6 Contour plot of cell charge at different % of total collected charge 20% 40% 60% 80% Increasing number of threshold levels reduces spatial error Minimum error around ≈ 57 % ( need further analysis) Normalized surface Q coll (x,y) vs. max(Qcoll(x,y)) CALICE D4 simulation results G.Villani feb. 06 Epitaxial thickness: 15 μm

7 7 Maximum signal around 420 - 460 e - when Σ Effect of spread of charge can be limited by increasing number of levels threshold Is there an ‘optimum’ thickness of epitaxial layer ? Conclusions CALICE D4 simulation results G.Villani feb. 06

8 8 Collection with different thicknesses 15 μm 20 μm


Download ppt "1 CALICE D4 simulation results G.Villani feb. 06 Cell size: 25 x 25  m 2 Epitaxial thickness: 20  m Diode location: S4 Diode size: 1.5 x 1.5  m 2 Cell."

Similar presentations


Ads by Google