Download presentation
Presentation is loading. Please wait.
1
MICE LH2 ABSORBER BODY Shigeru ISHIMOTO KEK OCT-10-2003 Non-Welding Bolt-Type Absorber
2
1.Non-Welding Flange 2.SS-Bolt + Helisert 3.Double-Indium-Seal and/or Double-Helicoflex-Seal 4.Key Structure to Prevent the Slip Due to Thermal Expansion 5.Fit to Ed’s Vacuum Vessel and KEK Test Cryostat 6.G10-Support 7.Option Screws for Thermometers * KEK funds to build new test absorber in FY03. * Use KEK cryostat as MICE test bench at FNAL Proposed Design
3
D300 Absorber in KEK Test Cryostat
5
KEK Test Cryostat with D300 Absorber (Now at FNAL)
6
D300 Absorber in MICE Vacuum Vessel
7
In-seal and Helicoflex/Metal seal on same body
8
D300 Absorber in MICE Vacuum Vessel
10
1.We need non-welding flange to fabricate and maintenance, also for solid targets. 2.We can use bolt-type flange for LH2 absorber if we use Helisert on the aluminum body. 3.Indium and/or Helicoflex seals will work well at 20K. 4.KEK cryostat is possible to use for D300 absorber test. 5.KEK funds to fabricate D300 test absorber in FY03. Summary