Seismic Refraction Method for Groundwater Exploration Dr. A K Rastogi Professor, Dept. of Civil Engineering I I T Bombay.

Similar presentations


Presentation on theme: "Seismic Refraction Method for Groundwater Exploration Dr. A K Rastogi Professor, Dept. of Civil Engineering I I T Bombay."— Presentation transcript:

1 Seismic Refraction Method for Groundwater Exploration Dr. A K Rastogi Professor, Dept. of Civil Engineering I I T Bombay

2 Ground water is not available everywhere in the subsurface region and therefore it is very important first step in groundwater hydrology to identify the existence of aquifer in a particular area. It is only after the presence of an aquifer is established, the scheme of groundwater withdrawals can be planned,

3 Groundwater exploration can be divided into two major groups involving geohydrological and geophysical methods. Geophysical Methods are indirect methods which does not involve drilling Seismic Refraction is a geophysical method

4 The following information can be derived from the exploration using geophysical methods: 1.Depth of occurrence and thickness of aquifers. 2.Delineation of aquifer boundaries of very large groundwater basin. 3.Determination of distinctly different water bearing layers.

5 The seismic refraction method involves artificial generation of elastic waves in the ground. Elastic waves travel with different velocities in different subsurface formations (2.5-6.5 km/s in the rocks, 1-2.5 km/s in sandy aquifers, and 0.31-0.61 km/s in the non aquifer overburden.) These waves behave similar to light waves while passing from one medium to another. When acoustic impedance contrast ρ 1 V 1 ≠ ρ 2 V 2, the elastic waves undergo changes in their directions of onward travel due to reflection and refraction and get returned to the earth surface due to refraction.

6 The shock waves are generally produced by exploding dynamite (about 500 gm) in a hand augured backfilled hole of about one meter depth. Sometimes, the method of hammering a thin plate placed over ground surface is also used. On the emergence of these waves after refraction from the subsurface boundary, these are detected by a suitable device called as geophones. These geophones are kept in a line at 5- 20 m interval. On receiving the elastic wave, geophones transmit electric signals. These signals are generally weak, and therefore, amplified and then recorded. Thus, the time of origin of shock waves and their first arrival on the surface either as direct waves or refracted waves (in distant geophones) are noted down in the seismic refraction.

7 Components of a geophone

8 Principle of Seismic Refraction Let A be a source on the ground surface and a seismic refractor underlies at a depth H from the source. The seismic wave reaches the point B which falls in other medium. If T is the total time for the seismic wave to travel a distance APB from low velocity medium V 1 to higher velocity medium V 2,

9 Differentiating with respect to x and making dT/dx = 0 gives For the seismic refraction to take place along the inter face boundary, r = 90 o, and if the corresponding angle of incidence is θ,. Or

10

11 x1x1 x2x2 x 10 x9x9 x6x6 x7x7 x8x8 x4x4 x5x5 x3x3 Shot Detector Distance in m Time of First Arrivalin millisecond

12 Determination of Depth to Aquifer (a) Intercept time method For direct waves For refracted waves

13 The slope of this segment on the travel time curve is 1/V 2 and the intercept on the time axis is Therefore, the depth to the formation is given as:

14 (b) Cross-over distance method The cross-over distance method is another way of finding H. Since the field data do not exhibit an exact straight line fit, it is advisable to cross-check the results using other methods, such as the cross-over distance method. As both direct and refracted waves arrive at the geophone together. At less than this direct wave reaches first, at more than this refracted wave reaches first. Hence, for X= X D, T D = T R

15 Exploration for Aquifer Thickness

16

17

18 Correction for Undulating Topography

19 Determination of the Sloping Aquifer Thickness Principle of Reverse seismic profiling is used According to this principle time for travel along ABCD is equal to the time for travel along the path DCBA A B C D E F

20

21 Conclusions Seismic Refraction method can be effectively used to find the depth of occurrence of the aquifer. It can find the thickness of the aquifer. It can find the angle of slope of the sloping aquifer by reverse seismic profiling. It can take care of the undulating topography which is normally present in many field situations. It can not predict about the quality water quality.