Presentation is loading. Please wait.

Presentation is loading. Please wait.

Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 1 DAMPING RING BASELINE TECHNICAL REVIEW CONVENTIONAL FACILITIES AND SITING.

Similar presentations


Presentation on theme: "Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 1 DAMPING RING BASELINE TECHNICAL REVIEW CONVENTIONAL FACILITIES AND SITING."— Presentation transcript:

1 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 1 DAMPING RING BASELINE TECHNICAL REVIEW CONVENTIONAL FACILITIES AND SITING GROUP CFS Damping Ring Mechanical and Electrical Tunnel Specifications V. Kuchler

2 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 2 Preparation for the DR BTR Several Aspects of the Damping Ring Design Were DiscussedSeveral Aspects of the Damping Ring Design Were Discussed  Personnel will not Occupy the RF Cavern During Beam On Conditions  Final Configuration of the RF Cavities, Klystrons and Related Equipment  A Thermal/Radiation Barrier will be Required Between the RF Equipment Cavern and the Damping Ring Tunnel  Beamline Spacing was Established  Tunnel Temperature Requirements were Established Including the Need for Temperature Isolation of Wiggler Areas  Magnet Power Supply Spacing and Configuration  Requirements for Equipment Alcoves for Injection/Extraction Straight Section

3 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 3

4 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 4 Courtesy Benno List

5 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 5

6 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 6 Plan at Damping Ring RF Straight Section Wiggler Enclosures Thermal/Radiation Shielding Wall Continuous Aisle to Shaft

7 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 7 Plan at Damping Ring Injection/Extraction Straight Section Power Supply Alcove Injection and ExtractionCaverns Floor Transition

8 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 8 Infrequent Personnel Access and Passive Equipment Major Personnel Access And Egress and Equipment Transport Center of DR

9 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 9 Main Linac Damping Ring ML RTML Ht is 2748 mm DR e- Ht is 2200 mm

10 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 10

11 Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review Summary Some Refinement of the Civil Drawings is Still Required to Support the New Cost EstimateSome Refinement of the Civil Drawings is Still Required to Support the New Cost Estimate Mechanical and Electrical Drawings are Being Produced by the Americas Region ConsultantMechanical and Electrical Drawings are Being Produced by the Americas Region Consultant Civil Cost Numbers Should be Available in 3-4 weeksCivil Cost Numbers Should be Available in 3-4 weeks Mechanical and Electrical Costs will not be Available Until SeptemberMechanical and Electrical Costs will not be Available Until September The CFS Damping Ring Criteria Format will Be Used for the Remaining Area SystemsThe CFS Damping Ring Criteria Format will Be Used for the Remaining Area Systems We Hope the Level of Detail Provided will Remain ConsistentWe Hope the Level of Detail Provided will Remain Consistent 11


Download ppt "Global Design Effort - CFS 07-07-11 Damping Ring Baseline Technical Review 1 DAMPING RING BASELINE TECHNICAL REVIEW CONVENTIONAL FACILITIES AND SITING."

Similar presentations