Presentation is loading. Please wait.

Presentation is loading. Please wait.

Voltage Security Margin Assessment Professor Dr. Garng Huang PS ERC.

Similar presentations


Presentation on theme: "Voltage Security Margin Assessment Professor Dr. Garng Huang PS ERC."— Presentation transcript:

1 Voltage Security Margin Assessment Professor Dr. Garng Huang PS ERC

2 Task 1 zModeling of control devices, loads and transactions for stability evaluations. Subtasks z1.1 Modeling FACTS devices [3] z1.2 Modeling Tap-changing transformers for its reactive power drawing capability [8] z1.3 Modeling exciters for its reactive power supporting and voltage regulatingcapability [6,8] z1.4 Modeling loads [8] z1.4 Modeling transactions [5,9,10] Task 2 zUse of Stability Margin and Stability Index Calculations Subtasks z2.1.Develop a program according to the new models to simulate the dynamic responses [4,8] z2.2.Analysis of Modeling Impacts [6,7] z2.3.Use of stability indices as a transaction scheduler [1,2] z2.4Use of utilization indices developed in 2.2 as basis for auxiliary service charges. [5,6,7,11] z2.5Use of 2.4 results as equipment investment indicators based on 2.4 results [5,6,7]

3 Task 3 zTransaction based stability margin and utilization factors calculation Subtasks z3.1 Formulate the transaction based power flow analysis problem [9,10,11] z3.2 Develop software for transaction based power flow analysis for decompositions [9,10] z3.3 Develop software to calculate utilization factor for control equipments [6] z3.4 Develop software for finding decomposed utiliziation factors and stability margins for individual transactions. [5] z3.5Combining results from 3.2 and 3.3 to decompose the margins and utilization factors to individual transactions. [5,6]

4 z1. G M Huang, N C Nair, “An OPF based Algorithm to Evaluate Load Curtailment Incorporating Voltage Stability Margin Criterion”, Conference proceeding of NAPS 2001, TX. z2. G M Huang, N C Nair, “Voltage Stability Constrained Load Curtailment Procedure to Evaluate Power System Reliability Measures”, IEEE/PES WM 2002, NY z3. G M Huang, N C Nair, ”Incorporating TCSC into the Voltage Stability Constrained OPF Formulation”, IEEE/PES Summer meeting 2002, Chicago. z4. G M Huang, N C Nair, “Detection of Dynamic Voltage Collapse”, IEEE/PES Summer meeting 2002, Chicago. z5. G M Huang, N C Nair, “Allocating Usages of Voltage Security Margin in Deregulated Electric Markets”, Submitted to ISCAS 2003, Thailand. z6. G M Huang, K Men,” Contribution Allocation for Voltage Stability In Deregulated Power Systems ”, IEEE 2002 PES, Summer meeting, Chicago. z7. G M Huang, L Zhao, X Song, “A new bifurcation analysis for power system dynamic voltage stability studies”, IEEE 2002 PES, Summer Meeting, Chicago z8. G M Huang, H Zhang, “Dynamic voltage stability reserve studies for deregulated environment” IEEE 2001 PES, Summer Meeting, Canada z9. G M Huang, H Zhang, “Transaction-Based Power Flow Analysis for Congestion Management and Responsibility Evaluation” presented at 2001 IEEE/PES Winter Meeting, Panel Session: Transmission Congestion Management and Reliability, Columbus, Ohio, Jan. 2001. z10. G M Huang, H Zhang, “Transaction Based Power Flow analysis For Transmission Utilization Allocation” 2001 IEEE/PES Summer Meeting. z11. G M Huang, H Zhang, “Transmission Loss Allocations and Pricing Via Bilateral Energy Transactions” 1999 IEEE/PES Summer Meeting. Publications

5 Voltage Stability Indicator

6 Voltage Stability Constrained OPF Formulation

7

8 TB-VMA Algorithm: Step 1 Decompose nodal currents based on transactions PX = Pool type transaction TX = N T Bilateral transactions Suffix Q represents the system wide reactive market

9 TB-VMA Algorithm: Step 2 Decompose nodal voltage components from decomposed current components Suffix, PX = Pool type transaction TX = N T Bilateral transactions Suffix Q represents the system wide reactive market

10 TB-VMA Algorithm: Step 3 Complex Power Delivered at Load buses, based on scheduled transactions Suffix, PX = Pool type transaction TX = N T Bilateral transactions

11 Step 3… Continued Index L formulation based on transaction based voltage decomposition Suffix, PX = Pool type transaction TX = N T Bilateral transactions

12 TRANSACTION PATTERN

13 Line parameters

14 Result of TB-VMA with and without line contingency of Line 4-9 outage Index Evaluated at Buses Before Contingency Index Evaluated at Buses After Contingency Transaction #2 of bus 7 increases the load bus 9 index. Because generator at bus 2 is involved in both PX#1 and TX # 2. The above effect is magnified in case of a contingency. Bus 9 is driven closer towards voltage collapse. This is because of loss of support for bus 9 from generator 1 because of loss of line

15 TB-VMA Application Scope zResponsibility Settlement of Voltage Security zNode-wise Voltage Stability Margin Utilization Evaluation zEvolve Transaction Based Pricing Mechanism for Voltage Security zA Tool to confirm whether a Transaction could be committed from voltage security margin viewpoint zA Tool to decide which transaction if curtailed gives maximum effect in case of potential voltage collapse situation


Download ppt "Voltage Security Margin Assessment Professor Dr. Garng Huang PS ERC."

Similar presentations


Ads by Google