1 Evolution Daikin Chiller Range
New Daikin Products 2007

2 Daikin Chillers range Important features: Price, efficiency, reliability 2 main sections can be distinguished: Aircooled units and watercooled units. These ranges will be discussed more in detail, started from the aircooled range:

3 Air-cooled range: Air-cooling capacity (kW) Class/ kW 50 100 250 500
750 1000 1250 1500 2000 Mini-chiller: EWA/YQ AC R-410a EUWA/Y5-24KA EWAP MB EWAP800-C18AJ R-407c EWA/YP CA In the aircooled range, the nominal capacity of chiller units offered by daikin, is between 5 kW (minichiller) all the way up to kW. Mainly one of 2 refrigerants is used : R407C and R134a. The R407c range is predominantly used for comfort cooling, while the higher efficiency R134a range is ideal for process or higher spec applications. Process applications require a certain amount of ensured cooling, even during a breakdown of chiller part. Depending on the type, 1 chiller unit contains either a single, a dual circuits or a ternary refrigerant circuit, sharing a single evaporator. The amount of independent circuits, shown as different colors on the graph, indicate a reliability, (and a price difference), since every circuit contains at least one compressor, a condenser and an expansion valve (+ a filter, an oil seperator) . Furthermore, the difference between EWAD650-C18BJ Some ranges at smaller capacities (up to 260 kW) are available in heat pump versions (Y in the name), the rest are cooling only chillers. EWAD AJ EWAD650-C18BJ R-134a 1 circuit 2 circuits 3 circuits 4 circuits EWAD MB

4 Water-cooled range: Water-cooling capacity (kW) Class/ kW 50 100 250
500 750 1000 1250 1500 2000 1 circuit 2 circuits 3 circuits 4 circuits EWWP KA (Scroll) R-407c EWWD MB EWWD DJ R-134a These compact systems use water (well water, city water, ...) for the cooling or heating process Can be installed in a machine room, thus reduced noise Used in home, commercial, office and industrial applications Extra Information on each Series: EWWP-KA: Single circuit for kw, dual circuit kW (single unit), 2 units (4 cirq) up to 141 kW and climbing up to 6 truly independent circuits (3 units) for a 200 kW unit. The control of the 3 units is common and the units operate as one single chiller. Ewwd-MB: single cirquit kw, dual cirquit from EWWD-DJ has change over from 165 kW-280kW and 2cirquit kW BJ series: High efficiency, all the way (2X flooded): Good efficiency, but expensive solution, since 2 flooded heat exchanger, and high refrigerant volume. Motivation for MB <--> DJ type: MB has plate heat exchanger condenser, while DJ has Shell and tube condenser: Thus MB allows faster and more precise control at fluctuating conditions, while DJ is more stable, needs less stringent water quality, but at somewhat higher cost (and slightly more refrigerant). Furthermore, the specs are very comparable. The market will descide which series will be continued. EWWD340-C19CJ Flooded technology EWWD380-C11BJ

5 Frame3100 & 3200 single screw compressor
EWAD AJYNN Frame3200 Frame3100 Cooling range: 177 – 626 kW Frame3100 & 3200 single screw compressor 2 efficiency versions: Std up to 2,77 and high up to 3,20 (EER) 2 refrigerant circuits truly independent DX shell & tube evaporator – One pass refrigerant side 4 noise levels (ST-OPRN-OPLN-/Q-/A-/H) down to 62 dB(A) R134a Ecologic Refrigerant

6 Frame4 Single-Screw Compressor
EWAD650-C18BJYNN Frame4 Cooling Range: 606 – 1920 kW Frame4 Single-Screw Compressor 2 efficiency versions: Std up to 2,93 and High up to 3,32 (EER) 2 – 3 – 4 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side 4 noise levels (ST-OPRN-OPLN-Q/Z) down to ISO 3744 R134a Ecologic Refrigerant

7 Frame4 Single-Screw Compressor
EWAP800-C18AJYNN Frame4 Cooling Range: 744 – 1729 kW Frame4 Single-Screw Compressor 2 efficiency versions: Std up to 2,34 and High up to 2,69 (EER) 2 – 3 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side 3 noise levels (ST-OPRN-OPLN) down to ISO 3744 R407C Ecologic Refrigerant

8 Frame3200 Single-Screw Compressor
EWWD DJYNN Frame3200 Cooling Range: 166 – 604 kW Frame3200 Single-Screw Compressor 2 efficiency versions: Std up to 4 and High up to 4,7 (EER) 1 – 2 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side Electronic Expansion device as standard R134a Ecologic Refrigerant

9 Frame4 Single-Screw Compressor EER range: 4,1 – 4,6
EWWD340-C19CJYNN Frame4 Cooling Range: 334 – 1893 kW Frame4 Single-Screw Compressor EER range: 4,1 – 4,6 1 – 2 – 3 – 4 truly independent refrigerant circuits DX shell & tube evaporator – One pass refrigerant side Electronic Expansion device as standard R134a Ecologic Refrigerant

10 VERY HIGH PART LOAD PERFORMANCE
EWWD380-C11BJYNN Frame4 Cooling Range: 369 – 1050 kW Frame4 Single-Screw Compressor EER up to 5,8 Very high EER values at part loads condition Flooded Evaporator Expansion valve with liquid level control R134a Ecologic Refrigerant VERY HIGH PART LOAD PERFORMANCE

11 Overview on Nomenclature
New Daikin Products 2007

12 Daikin nomenclature (std unit)
EWA EWA Air-Cooled Chiller C/O EWT Air Cooled Chiller C/O + H/R EWY Air-Cooled Chiller H/P EWC Air-Cooled Chiller Centr. Fan EWW Water-Cooled Chiller EWL Remote Condenser Chiller C/O = Cooling Only H/P = Heat Pump H/R = Heat Recovery ERA Air Cooled Condensing unit C/O

13 Daikin nomenclature (std unit)
EWA D Kind of Refrigerant D: R- 134a P: R- 407C Q: R- 410A

14 Daikin nomenclature (std unit)
EWA D 360 Capacity Class kW(!) Cooling From 1 to 950 kW Above 950 kW: Use multiples of C (Roman Character for 100) 1000 kW = C10 (100x10) 2500 kW = C25 (100x25)

15 Daikin nomenclature (std unit)
EWA D 360 AJ Model Series First Character Letter A,B,… Major Modification Second Character Letter A,B,… Minor Modification

16 Daikin nomenclature (std unit)
EWA D 360 AJ YN Power Supply YN : 3~ / 400V / 50Hz W1 : 3N~ / 400V / 50Hz Y1 : 3~ V / 50Hz V1 : 1~ / V / 50Hz V3 : 1~ / 230V / 50Hz T1 : 3~ / 230V / 50Hz

17 Daikin nomenclature (option mix)
EWA D 360 AJ YN N Hydronic Module choices Heat Recovery version N : No Hydronic component (Std) P : Pump + hydronics B : P + Buffertank A-V: Combinations of options like special or dual pumps and Heat recovery.

18 Daikin nomenclature (option mix)
1 EWA D 360 AJ YN N **** Option Mix **** : 4 digits

19 Daikin nomenclature (std unit)
EWA D 360 AJ YN N **** /A Sound & Efficiency related options /A /Q /Z /H Standard Efficiency (SE) High Efficiency (HE) SE + Extra low noise HE + Extra low noise High Ambient

20 Noise & Efficiency Std Noise, Std Efficiency Base Model
EWA D 360 AJ YN N /A Std Noise, Std Efficiency Base Model OPRN: Reduced Noise, excludes compressor cabinet OPLN: Low Noise, includes compressor cabinet Std Noise, High Efficiency “/A” Base Model Extra Low Noise, Std Efficiency “/Q” Base Model Extra Low Noise, High Efficiency “/Z” Base Model High Ambient = “/H” Base Model /A /Q /Z /H

21 Standard Daikin Options

22 Standard Options Available

23 40 46 10