FVCC Fire Rescue Ventilation Part A Truck Company Operations Review of Ventilation Principles & Practices.

Similar presentations


Presentation on theme: "FVCC Fire Rescue Ventilation Part A Truck Company Operations Review of Ventilation Principles & Practices."— Presentation transcript:

1

2 FVCC Fire Rescue Ventilation Part A

3 Truck Company Operations Review of Ventilation Principles & Practices

4 Principles of Ventilation Truck Company Operations can be performed without access to the use of a aerial apparatus.

5 OBJECTIVES 2-11.1Identify the definition and principles of ventilation and the considerations of proper ventilation (3-3.10) 2-11.2Identify the safety considerations and precautions to be taken while ventilating a structure. (3-3.10, 3-3.11)

6 OBJECTIVES 2-11.3Identify the advantages and disadvantages of the following types of ventilation: ▫2-11.3.1Vertical (3-3.11) ▫2-11.3.2Horizontal (3-3.10) ▫2-11.3.3Trench/strip (3-3.11) ▫2-11.3.4Mechanical (3-3.10) ▫2-11.3.5Mechanical pressurization/positive pressure ventilation (3-3.10) ▫2-11.3.6Hydraulic (3-3.10)

7 OBJECTIVES 2-11.4Identify the signs, causes and effects of backdraft explosions. (3-3.10) 2-11.5Identify methods of preventing a backdraft explosion. (3-3.10) 2-11.6Identify the characteristics of the following roof types: (3-3.10, 3-3.11)

8 OBJECTIVES ▫2-11.6.1Flat ▫2-11.6.2Shed ▫2-11.6.3Pitched ▫2-11.6.4Arched 2-11.7Identify the types of tools used during ventilation. (3-3.10)

9 OBJECTIVES 2-11.8Identify the necessary precautions when ventilating the following roof types: ▫2-11.8.1Flat ▫2-11.8.2Shed ▫2-11.8.3Pitched ▫2-11.8.4Arched

10 OBJECTIVES 2-11.9Identify the procedures for the types of ventilation referred to in 2-11.3 (3-3.10, 3-3.11) ▫2-11.9.1Vertical (3-3.11) ▫2-11.9.2Horizontal (3-3.10) ▫2-11.9.3Trench/strip (3-3.11) ▫2-11.9.4Mechanical (3-3.10) ▫2-11.9.5Mechanical pressurization/positive pressure ventilation (3-3.10) ▫2-11.9.6Hydraulic (3-3.10)

11 OBJECTIVES 2-11.10Identify how the following factors are used to determine the integrity of a roof system: (3-3.10, 3-3.11) ▫2-11.10.1Construction ▫2-11.10.2Visual observation ▫2-11.10.3Elapsed time of fire Identify the procedures for opening various types of windows from inside and outside with the use of tools. (3-3.10)

12 OBJECTIVES 2-11.12Identify the procedures for opening various types of windows from inside and outside without the use of tools. (3-3.10) 2-11.13Identify the procedures for breaking window or door glass and removing obstructions. (3-3.10) 2-11.14Identify ventilation using water fog. (3- 3.10, 3-3.11)

13 OBJECTIVES 2-11.15Demonstrate opening various types of windows from inside and outside with the use of tools. (3-3.10(b)) 2-11.16Demonstrate opening various types of windows from inside and outside without the use of tools (3-3.10(b))

14 OBJECTIVES 2-11.17Demonstrate breaking window or door glass and removing obstructions. (3-3.10(b)) 2-11.18Demonstrate the removal of skylights, scuttle covers, and other roof openings. (3- 3.10(b)) 2-11.19Demonstrate ventilation using water fog. (3-3.10(b)), (3-3.11(b))

15 OBJECTIVES 2-11.20Demonstrate determining the integrity of a roof system by sounding. (3-3.11(b)) 2-11.21Demonstrate the ventilation of a flat roof using both hand tools and power tools. (3- 3.11(b)) 2-11.22Demonstrate the ventilation of a pitched roof using both hand tools and power tools.

16 OBJECTIVES 2-11.23Demonstrate floor ventilation procedures. (3-3.11(b)) 2-11.24Demonstrate the use of positive pressure ventilation. (3-3.11(b)) ▫Ifsta, Essentials, 4 th ed, Chapter 10 ▫Delmar, Firefighter’s Handbook, copyright 2000, Chapter 18

17 Principles of Ventilation Ventilation: the planned & systematic removal of heat, smoke and toxic gases from an area and the replacement of these products with cooler fresher air. Planned aspect should be done during pre- incident planning to help identify buildings with light weight or wooden trusses.

18 Reduces Mushrooming Effect

19 Principles of Ventilation Considerations ▫Roof type  Flat  Arched  Pitched ▫Type of building involved ▫Location of the fire ▫Duration of the fire ▫Extent of the fire ▫Existing roof openings

20 Principles of Ventilation Effects of proper ventilation: 1. Better visibility 2. Reduced temperature levels 3. Reduced possibility of back draft (heat & smoke removal) or flashover (heat removal). 4. Easier to locate seat of fire or victims. 5. Reduced smoke damage to property.

21 Principles of Ventilation Advantages of ventilation toward fire suppression operations: 1. Assists with victim rescue. 2. Increases fire attack. 3. Reduces possibility of back draft/flashover. 4. Aids in property conservation (fire confinement).

22 Principles of Ventilation Signs of backdraft (smoke explosion): Pressurized smoke appearing from small cracks Puffing smoke at intervals from the building Smoke stained windows New construction increase likelihood of backdraft because energy conservation measures trap heat inside structure. Smoke is a grey-yellow color or changes color. Sparking like effect of fire Little or No visible signs of flame. Inward movement of smoke.

23

24

25 PREVENTING A BACKDRAFT EXPLOSION Provide vertical ventilation at highest point to permit the release of superheated gases.

26 Principles of Ventilation Disadvantage: 1) Does not reduce the risk of fire flare up. 2) Increase fire intensity/spread. 3) Requires firefighters to work above the ground. 4) Possibility of roof failure. 5) Requires close communication.

27

28 Safety Precautions Leader of the roof team you are RESPONSIBLE for: Make sure only the required ventilations are made Direct efforts to minimize secondary damage caused by firefighters ventilating. Insuring safety of all personnel who are working on the roof.

29 Safety Precautions When considering the ventilation of a burning structure, the SAFETY of the occupants & your crew is the first priority. Decide if there is a need to ventilate and if so what type of ventilation is needed?. Rescue operations can begin: a) prior to ventilation b) simultaneously to ventilation c) after ventilation operations have begun d) depends upon the circumstances

30 Safety Precautions When ventilating a structure, firefighters should wear full PPE and SCBA. (Do’s)

31 Safety Precautions (continued) Don’ts: When ventilating a structure, firefighters should wear full PPE and SCBA.

32 Safety Precautions Always vent at the HIGHEST point if possible. Helps reduce chances of backdraft.

33 Safety Precautions Have hose lines in place and ready to make your attack. During vent/ops, charged hose lines should be in place at all times and should be located at the attack entrance, immediate point where the fire could be expected to spread, and positions to protect exposures.

34

35 Safety Precautions Always work with the wind at your back or side when cutting vent holes or venting windows. ? Of course, you must always use the proper tool (ladder)for the job.

36

37 Safety Precautions Never place a hose line or elevated stream into a ventilation opening. Especially with fire suppression crews working below. Elevated streams are fire streams that are Directed over ventilation holes to help cool the thermal column, lessen sparks & flying brands.

38

39 Safety Precautions Check stability of the roof before starting ventilation operations.

40 Safety Precautions Restrict number of personnel working on roof to minimum to accomplish task.

41 Safety Precautions Always work from a roof ladder when cutting hole on a pitched roof.

42 Safety Precautions Always work from a roof ladder when cutting hole on a pitched roof. (Don’ts)

43 Safety Precautions ▫Extend ladders at least five rungs above the roof line. ▫“Sound” the roof for structural integrity before stepping on it. ▫Use supporting members of the structure for travel. ▫When using a roof ladder, make sure it is firmly secured to the peak of the roof before using it. ▫Work in groups of two, with no more people than absolutely necessary. ▫Be aware of the following warning signs of an unsafe roof condition:  Melting asphalt  “Spongy” roof  Smoke coming from the roof  Fire coming from the roof

44

45 Safety Precautions Watch out for overhead power lines.

46 Ladder Placement

47

48 Safety Precautions Have a secondary escape route from roof. Which should be located as far away from your ventilation hole as possible.

49

50 Safety Precautions Check power tools on the ground to make sure they will start before taking to the roof. Shut off power tools before carrying up ladder. Rotor rescue saw Carbide tipped chain saw Vent saws

51 Safety Precautions Always take a pick-headed axe (Axe will always start). Keep other firefighters out of range of the axe. Caution axe users to beware of overhead obstructions.

52 Safety Precautions Be careful not to cut main structural supports. Cut roof material diagonally along side of joists. Make sure the angle of the cut is directed toward your body.

53

54

55 Safety Precautions Watch out for unsafe roof conditions. Lapping Signs: melting asphalt, “spongy roof”, smoke coming from roof, fire coming from roof.

56 Safety Precautions Maintain communications capability with ventilation crew.

57 Safety Precautions Remove crew from roof after ventilation hole is completed. 4 ft

58 Safety Precautions Ventilation should be performed only after the seat of the fire has been located. Basement fires are some of the most challenging fires for firefighters. Windowless buildings create an adverse effect on firefighters & vent/ops. Availability & involvement of exterior fire escapes & exposures. Number & size of wall openings Number of stories, stair cases, dumb waiters, ducts & roof openings the structures has to offer.

59 Safety Precautions Do not place ladders in front of entry or exit points-keep these areas free for fireground operations and victim egress. Do not place ladders over windows or doors when going to upper floors or the roof. Should fire vent out a window or door, it will compromise the ladder and its use.

60 the pitch of the roof and the ridge vent can prevent the hooks of the roof ladder from properly engaging the roof and can result in your being able to pull a roof ladder off the roof with only a slight tug

61 To avoid this, take the hook of a halligan tool and drive it into the roof just past the ridge

62 This enables you to safely secure the hook(s) of the roof ladder to the roof

63 As always, when working on a pitched roof without a roof ladder, use a halligan tool or pickhead ax with the hook driven in for balance.

64

65 Risk Management L.I.B.


Download ppt "FVCC Fire Rescue Ventilation Part A Truck Company Operations Review of Ventilation Principles & Practices."