University of Aveiro Department of Environment and Planning NATO ASI – 7 th of May 2004 – Kyiv, Ukraine J.H. Amorim, A.I. Miranda, C. Borrego Air pollutants.

Similar presentations


Presentation on theme: "University of Aveiro Department of Environment and Planning NATO ASI – 7 th of May 2004 – Kyiv, Ukraine J.H. Amorim, A.I. Miranda, C. Borrego Air pollutants."— Presentation transcript:

1 University of Aveiro Department of Environment and Planning NATO ASI – 7 th of May 2004 – Kyiv, Ukraine J.H. Amorim, A.I. Miranda, C. Borrego Air pollutants dispersion disturbance due to urban vegetation: a porous media modelling approach to Lisbon city centre

2 INDEX of the presentation Motivation and objective of the work Methodology applied General characterisation of the model: FLUENT Description of the study-case (Liberdade Av., Lisbon) FLUENT application to the study-case Results presentation and analysis Conclusions

3 MOTIVATION As buildings, although with less significant consequences, trees ( if existent ) act as roughness elements, modifying the wind field. Consequently, the analysis of the dispersion conditions within a given area may become incomplete if these impacts were not considered. What is the relative importance of the perturbations induced by vegetation on air pollutants dispersion within ? What is the relative importance of the perturbations induced by vegetation on air pollutants dispersion within urban environments? - densely populated - high road-traffic emissions Areas with problematic air quality standards Computationally challenging problems - complex 3D structures - turbulent flow field - trees are commonly found on cities

4 main OBJECTIVE and METHODOLOGY How far from the reality can we be if neglecting these effects?? As a first approach, the vegetative canopy effect over flow and air pollutants concentration fields inside a typical urban environment was simulated applying a simple empirical model.

5 FLUENT MODEL validation FLUENT vs Wind Tunnel - idealised urban geometry - Hot-wire anemometry (wind field comparison) - Flame Ionisation Detection (FID) (concentration field comparison) General purpose CFD commercial numerical model As FLUENT is intended for a wide range of engineering studies, its feasibility on local scale air quality modelling was previously evaluated. FLUENT vs CFD model (VADIS) - real urban geometry (Lisbon downtown) - wind and concentration fields comparison

6 FLUENT model (brief) characterisation Flow modelling: Eulerian approach Simplifications: Steady-state 3D flow (1 hour averaged input/output values) Incompressible fluid Turbulence modelling: Reynolds-averaged Navier-Stokes (RANS) equations closure: k-  model Dispersion modelling: Eulerian approach No chemical reactions: CO (inert pollutant)

7 FLUENT application to LIBERDADE Av. Simulation domain Liberdade Av. Lisbon downtown Simulation period: 24 h typical working day (6 th March, 2002)  Centred at Liberdade Avenue, one of the main thoroughfares of Lisbon city centre  aspect ratio: H/W = 0.33 “avenue canyon” (<0.5)

8 Air quality monitoring station (AQMS) 11 1 – Liberdade Av. 2 – Liberdade Av. (descending secondary lane) 3 – Liberdade Av. (ascending secondary lane) 4 – A. Herculano St. 5 – Rua B. Salgueiro St. 6 – Rua M. Silveira St. 7 – Rua R. Araújo St. 8 – Rua R. Sampaio St. 9 – Rua S. Marta St. 10 – Rua J. Machado St. 11 – Rua M. Coelho St. 12 – Rua do Salitre St a5a 5b5b Emission sources definition

9 Emissions estimation - developed at the University of Aveiro - based on MEET/COST methodology - emission factors are based on the average vehicles speed (this approach is considered correct when the influence of driving dynamics can be neglected) - vehicles emissions are estimated individually for each road segment considering detailed information on traffic flux counting (VISUM traffic model output) Road traffic emissions estimation: TRansport Emission Model for line sources (TREM) Traffic flux (n.º vehicles.h -1 ) CO emission (g.km -1.h -1 ) Time (h) Traffic flux counting (Liberdade Av.) CO emission estimated by TREM

10 Meteorological data - Meteorological station located nearby the computational domain - Hourly averaged values of: wind velocity and direction (10 m height), air temperature and RH - Variable wind velocity (minimum: 4 m.s -1 ; maximum: 7 m.s -1 ) - Predominant wind direction: NW - Boundary conditions: logarithmic vertical wind profile Wind velocity Wind direction S E N W S Time (h) Velocity (m.s -1 ) Direction

11 Special characteristic of the domain Presence of a large number of densely foliaged tall trees that flank the Avenue in its entire extension…

12 … creating a “green corridor” between both sides of the Av. and the houses. Vegetation characterisation a modified street-canyon wind pattern is expected due to the crown-induced disturbed flow.

13 The AQMS (National Air Quality Monitoring Net) is located within the expected disturbance induced by the trees foliage Vegetation characterisation

14 Domain 3D perspective

15 POROUS VOLUMES Shape: regular blocks Ground distance: 5 m Dimensions: var.  15 m  10 m (L  W  H) Porous medium modelling: Power-law approach Source-term [ S i, for the i th (x, y, or z) momentum equation ] that establishes a relation with the velocity ( v ): C 0 = 10; C 1 = 1 Domain 3D perspective with “vegetation” definition

16 top view Domain volume: 650 × 650 × 80 m 3 (L × W × H) Grid: ~1 million unstructured cells ( Gambit pre-processor: TGrid ) N.º buildings: 42 sets (  h: m) N.º emission sources: 12 N.º porous media: 6 sets Computational domain

17 time (h) CO concentration (µg.m -3 ) CO concentration (meas. & simul.) temporal variation AQMS FLUENT WITH porous media FLUENT WITHOUT porous media Not despite the empirical characteristics of this approach the results fit better with the measurements in this case.

18 Model performance statistical analysis More accurate modelling results are obtained when considering the porous media. Paired Statistical Comparison Metrics (ASTM Standard Guide for Statistical Evaluation of Atmospheric Dispersion Model Performance) WITH porous media WITHOUT porous media Fractional bias ( FB ) Normalised mean squared error (NMSE) Pearson correlation coefficient

19 Model performance statistical analysis – linear regression without porous media with porous media

20 Conc. CO µg.m -3 without porous media Concentration fields (z = 3 m) results intercomparison: Δt = a.m. Conc. CO µg.m -3 [CO] with = 1400 µg.m -3 [CO] without = 700 µg.m -3 [CO] measured = 1300 µg.m -3 AQMS

21 Vertical plane crossing the Av. through the AQMS.

22 Unstructured mesh Left -side building (Windward side) Liberdade Av. Right-side building ( Leeward side ) POROUS MEDIUM Secondary traffic lane (~10% Lib. emission rate) Secondary traffic lane (~10% Lib. emission rate)

23 without porous media Turbulent kinetic energy (TKE) k (m 2.s -2 ) Left -side building Right -side building with porous media

24 CO concentration C CO (µg.m -3 ) without porous media Left -side building Right -side building with porous media

25 Velocity x component without porous media Vx (m.s -1 ) Left -side building Right -side building Within the avenue-canyon, the porous medium diminishes the velocity component perpendicular to the Av. from its left to the right side +Vx

26 with porous media Velocity y component without porous media Vy (m.s -1 ) Left -side building Right -side building The porous medium diminishes the velocity component parallel to the Av. and in its descendant sense -Vy

27 with porous media Velocity z component Vz (m.s -1 ) without porous media Left -side building Right -side building Both negative and positive vertical velocity components within the avenue-canyon are diminished by the porous medium effect +Vz -Vz +Vz

28 with porous media C CO (µg.m -3 ) without porous media CO concentration contours plus wind velocity streamlines The recirculation across the street axis is still present, but the shape of the eddy has changed. Two additional vortices are formed.

29 without porous media with porous media C CO (µg.m -3 )

30 with porous media CO concentration contours plus velocity vectors C CO (µg.m -3 ) Because the exchange rate of air with the atmosphere at the above roof-level is diminished and emissions are made under the trees foliage, the formation of hot-spots is increased. without porous media Left -side building Right -side building

31 CO concentration C CO (µg.m -3 ) Within these dispersion conditions a CO concentration increase is obtained at the leeward side of the Avenue when the porous media is present. without porous media with porous media

32 CO concentration – results sensibility to vegetation height C CO (µg.m -3 ) 5 m height porous media 0 m height porous media

33 CO concentration – results sensibility to vegetation height C CO (µg.m -3 )

34 CO concentration – results sensibility to vegetation height The porous media trap pollutants within the emission source lateral boundaries, sheltering the buildings from the direct impact of traffic emissions on local air quality. C CO (µg.m -3 )

35 CONCLUSIONS The comparison between simulated and measured values shows that, although empirical and even incomplete from a physical point of view, the approach assumed is apparently more close to reality than it is the absence of it. A perturbation caused by trees over the wind field should in fact exist because of the discrepancy between the “normal” simulation and the measured values, but its effect needs to be more accurately modelled.

36 CONCLUSIONS Apart from all the assumptions made, the results suggest that the decrease of the velocity within the porous media, and the consequent weakening of the dispersion inside the canyon, has the potential to originate undesired effects on air quality. However, these kind of ultimate effects are extremely dependent upon the local specific dispersion conditions and on the configuration and intrinsic characteristics of the vegetative canopy present. As future work, an effort will be made in order to apply an appropriate and validated model for the simulation of the perturbations induced by trees on Lisbon downtown.