Presentation is loading. Please wait.

Presentation is loading. Please wait.

Scantronic 9x5x An introduction To the Scantronic 9x5x Range of Control Panels and Accessories Presented By Frank Grothe.

Similar presentations


Presentation on theme: "Scantronic 9x5x An introduction To the Scantronic 9x5x Range of Control Panels and Accessories Presented By Frank Grothe."— Presentation transcript:

1 Scantronic 9x5x An introduction To the Scantronic 9x5x Range of Control Panels and Accessories Presented By Frank Grothe

2 Scantronic 9x5x From Early 2002 the current 9750 and 9850 will be replaced with:From Early 2002 the current 9750 and 9850 will be replaced with: The 9751The 9751 The 9752The 9752 The 9851The 9851

3 The 9x5x Products , 8 zone Radio Expander 9930 LCD Keypad 9928 Keyswitch Interface 9954, 8 zone Hardwired Expander Built-in Multi Format Format Digi/ Modem 3/4 Fully ProgrammableO/COutputs 8 Zone on board 8 Secondary Communicationsoutputs Plus 868Mhz Class VI Radio Detectors and Transmitters

4 9x5x Architecture 9930 RKP 9x5x Control Panel 9930 RKP 9928 KSW9954 HWX or 9955 RFX 9954 HWX or 9955 RFX 9954 HWX or 9955 RFX 9954 HWX or 9955 RFX 8 Hardwired ZonesOn-board Built-inModem & Alarm Comms. 3/4 Panel Outputs 8 Secondary Comms.Outputs

5 9x5x Progression 9750UK UK UK EUR UK EUR EUR EUR EUR UK-00 Upgrades Replaces Replaces Replaces All Upgrades 9800UK UK UK UK-00 Replaces

6 9751 Hardware Features 8 zones on board expandable to 24 using remote hardwired or 868MHz Class VI radio expansion.8 zones on board expandable to 24 using remote hardwired or 868MHz Class VI radio expansion. Hardwired zones are FSL, EOL or CC configured.Hardwired zones are FSL, EOL or CC configured. Small Metal end station enclosure.Small Metal end station enclosure. 16 Character LCD remote keypad as standard.16 Character LCD remote keypad as standard. 3 transistorised panel outputs & 8 (plug-by) transistorised secondary communications outputs.3 transistorised panel outputs & 8 (plug-by) transistorised secondary communications outputs. Built-in Multi-format digital communicator and 300 baud V21 half duplex modem.Built-in Multi-format digital communicator and 300 baud V21 half duplex modem. Remote connect UDL.Remote connect UDL. Battery saver and PresenceBattery saver and Presence

7 9752 Hardware Features 8 zones on board expandable to 32 using remote hardwired or 868MHz Class VI radio expansion.8 zones on board expandable to 32 using remote hardwired or 868MHz Class VI radio expansion. Hardwired zones are FSL, EOL or CC configured.Hardwired zones are FSL, EOL or CC configured. Small Metal end station enclosure.Small Metal end station enclosure. 16 Character LCD remote keypad as standard.16 Character LCD remote keypad as standard. 2 relay + 1 transistorised panel outputs & 8 (plug-by) transistorised secondary communications outputs.2 relay + 1 transistorised panel outputs & 8 (plug-by) transistorised secondary communications outputs. Built-in Multi-format digital communicator and 300 baud V21 half duplex modem.Built-in Multi-format digital communicator and 300 baud V21 half duplex modem. Remote or Local connect UDL.Remote or Local connect UDL. Battery saver, Presence and Load testBattery saver, Presence and Load test

8 9851 Hardware Features 8 zones on board expandable to 40 using remote hardwired or 868MHz Class VI radio expansion.8 zones on board expandable to 40 using remote hardwired or 868MHz Class VI radio expansion. Hardwired zones are FSL, EOL or CC configured.Hardwired zones are FSL, EOL or CC configured. Large Metal end station enclosure.Large Metal end station enclosure. 16 Character LCD remote keypad as standard.16 Character LCD remote keypad as standard. 2 relay + 2 transistorised panel outputs & 8 (plug-on & plug by) transistorised secondary communications outputs.2 relay + 2 transistorised panel outputs & 8 (plug-on & plug by) transistorised secondary communications outputs. Built-in Multi-format digital communicator and 2400/300 baud V21 Full duplex modem.Built-in Multi-format digital communicator and 2400/300 baud V21 Full duplex modem. Remote or Local connect UDL.Remote or Local connect UDL.

9 9851 Hardware Features (2) 1.3 Amp Power Supply.1.3 Amp Power Supply. Capable of supporting a 17Ah battery.Capable of supporting a 17Ah battery. Battery saver, Presence and Load test.Battery saver, Presence and Load test. Scantronic local printer output.Scantronic local printer output. Provision in the PCB design for a upgrade kitProvision in the PCB design for a upgrade kit

10 9751 Function Features All Zones fully programmable for both 12 Character description (entry as mobile phone), type and attributes from keypads or Downloader.All Zones fully programmable for both 12 Character description (entry as mobile phone), type and attributes from keypads or Downloader. Full setting and 2 part set (A,B,C ) levels all with separate exit - entry mode, timers and alarm responses.Full setting and 2 part set (A,B,C ) levels all with separate exit - entry mode, timers and alarm responses. 16 x 4 digit user codes plus Duress and Installer code, all have a programmable 12 Character user name.16 x 4 digit user codes plus Duress and Installer code, all have a programmable 12 Character user name. Fully programmable output types for the 3 panel & 8 secondary communications outputs.Fully programmable output types for the 3 panel & 8 secondary communications outputs. Selection of any one alarm report formats - Fast Format, Contact ID, SIA I, SIA II or SIA III.Selection of any one alarm report formats - Fast Format, Contact ID, SIA I, SIA II or SIA III.

11 9751Functional Features Fully ACPO & DD243: 2002 Compliant.Fully ACPO & DD243: 2002 Compliant. Separate Country type and Language.Separate Country type and Language. Radio Supervision Fail programmable responsesRadio Supervision Fail programmable responses Programmable use of Telecommand to unset external to protected premises (DD234: 2002).Programmable use of Telecommand to unset external to protected premises (DD234: 2002). EN programmable options.EN programmable options. Two key PA, Medical assistance and Manual fire alarm from keypads.Two key PA, Medical assistance and Manual fire alarm from keypads.

12 9752 Additional Features Full setting and 3 part sets (A,B,C & D ) levels all with separate exit - entry mode, timers and alarm responses.Full setting and 3 part sets (A,B,C & D ) levels all with separate exit - entry mode, timers and alarm responses.

13 9851 Additional Features Full setting and 3 part sets (A,B,C & D ) levels or 4 Partitions all with separate exit - entry mode, timers, alarm responses and alarm reporting.Full setting and 3 part sets (A,B,C & D ) levels or 4 Partitions all with separate exit - entry mode, timers, alarm responses and alarm reporting. 16 x 4 or 6 digit user codes plus Duress and Installer code, all have a programmable 12 Character user name.16 x 4 or 6 digit user codes plus Duress and Installer code, all have a programmable 12 Character user name.

14 Common to all the 9x5x Panels are:Common to all the 9x5x Panels are: zone hardwired expander, wired on to keypad 4 wire bus, fully configurable zones (4 wire CC, EOL, FSL) zone hardwired expander, wired on to keypad 4 wire bus, fully configurable zones (4 wire CC, EOL, FSL) Single Line (16ch.) LCD keypad Single Line (16ch.) LCD keypad key switch Interface PCB for momentary and latched switches key switch Interface PCB for momentary and latched switches. Range of 868MHz Radio ProductsRange of 868MHz Radio Products 9x5x Ancillary Products

15 868MHz Radio Products Common to all the 9x5x Panels are: Common to all the 9x5x Panels are: zone Radio zone Expansion/Receiver, zone Radio zone Expansion/Receiver, connects on to the keypad 4 wire bus. connects on to the keypad 4 wire bus. 715r 12 metre passive infra-red with transmitter. 715r 12 metre passive infra-red with transmitter. 719r Photoelectric smoke detector / transmitter. 719r Photoelectric smoke detector / transmitter. 725r Remote set/unset fob with PA function. 725r Remote set/unset fob with PA function. 726r Two button PA transmitter. 726r Two button PA transmitter. 735r Door contact/universal transmitter. 735r Door contact/universal transmitter. 747r Simple GO-NOGO signal test meter & test Tx. 747r Simple GO-NOGO signal test meter & test Tx.

16 868MHz Radio Features Radio Frequency MHz with < 25KHz Radio Frequency MHz with < 25KHz bandwidth (Narrow Band). bandwidth (Narrow Band). Meets the requirements of pr EN “Grade 2” Meets the requirements of pr EN “Grade 2” for Europe generally and Skafor grade 2. for Europe generally and Skafor grade 2. All transmitters (except 725 & 726) transmit All transmitters (except 725 & 726) transmit supervision every 4 minutes. supervision every 4 minutes. Receiver uses patented IR address learn, (16 million Receiver uses patented IR address learn, (16 million differs). differs). Individual signal strength for transmitters and Individual signal strength for transmitters and telecommands can be viewed locally or via the telecommands can be viewed locally or via the Downloader. Downloader.

17 Remote Programming Fully configure the installed system remotely or via local direct link (9752 & 9851).Fully configure the installed system remotely or via local direct link (9752 & 9851). Configuration printout.Configuration printout. Account history log of all changes who, what and at what time & date.Account history log of all changes who, what and at what time & date. Simple modem handling and set-up.Simple modem handling and set-up. Outlook style operator interface.Outlook style operator interface.

18 9x5x Remote Operation All 9x5x Products will have Remote Functions:-All 9x5x Products will have Remote Functions:- Up/Downloading options of Attended site, Secure call-back, Customer initiated.Up/Downloading options of Attended site, Secure call-back, Customer initiated. Remote servicing and diagnostics facilityRemote servicing and diagnostics facility Zone Activity monitor, Zone Omitted, Zone in Soak Test, Zone Tampered or Zone Unused.Zone Activity monitor, Zone Omitted, Zone in Soak Test, Zone Tampered or Zone Unused. Zone resistance (panel and hardwired expander).Zone resistance (panel and hardwired expander). RF Zone status and signal strength, Supervision failed or Transmitter Low Battery.RF Zone status and signal strength, Supervision failed or Transmitter Low Battery. Separate Telecommands Signal Strength monitor.Separate Telecommands Signal Strength monitor.

19 Output status and individual Test functions for panel and plug-on/by communications outputs.Output status and individual Test functions for panel and plug-on/by communications outputs. PSU DC voltage, System current load, Battery load voltage and Battery charge current plus DC and AC Monitors.PSU DC voltage, System current load, Battery load voltage and Battery charge current plus DC and AC Monitors. Remote Communications Test function.Remote Communications Test function. A virtual keypad will allow customer shadowing or system access for all panel functions.A virtual keypad will allow customer shadowing or system access for all panel functions. Event log download, save and print options.Event log download, save and print options. System profile - (as installed) specifications printable.System profile - (as installed) specifications printable. More 9x5x Remote Operation

20 9x5x Downloader

21

22

23 9x5x Products Conformity All Products Comply with EN for EMC, CTR21 for PPT, EN60950 for safety.All Products Comply with EN for EMC, CTR21 for PPT, EN60950 for safety. And the following Industry regulations:And the following Industry regulations: The EN Grade 1,The EN Grade 1, The EN Grade 2, FG, RUS, SKAFOR 1 or 2The EN Grade 2, FG, RUS, SKAFOR 1 or 2 The EN Grade 2, FG, RUS, SKAFOR 2.The EN Grade 2, FG, RUS, SKAFOR 2. The EN Grade 3, FG, RUS, SKAFOR 3.The EN Grade 3, FG, RUS, SKAFOR 3.

24 9x5x in the future ! 9x5x wireless system (Narrow Band). 16 zones …… 9x5x wireless system (Wide Band) 16 zones ……