Presentation is loading. Please wait.

Presentation is loading. Please wait.

The LOGIQ 200 PRO Series.

Similar presentations


Presentation on theme: "The LOGIQ 200 PRO Series."— Presentation transcript:

1 The LOGIQ 200 PRO Series

2 LOGIQ 200 PRO Series Image Quality Professional Productivity
Progress Investment Protection The PRO Series represents outstanding value for the most discerning professional, delivering increased productivity and superior diagnostic outcomes for you and your patients.

3

4

5 RELAY SCANNER INTERFACE
SCAN Board RELAY CON 1 CON 2 -SHV +SHV SCANNER INTERFACE USC BUS

6

7 TBF TX DRV PRE AMP \ CROSS POINT P GUN ASSY WATCH DOG INTERFACE
PGC P GUN ASSY \ CROSS POINT +THV -THV WATCH DOG INTERFACE USC BUS NOVA BUS

8

9 RBF PGC ACC GEN TO MVP TGC COSMO ADC AAF DDS IIC USC BUS NOVA BUS

10 40MHz Ultra-High frequency
Digital Beamformer Σ Digital Time Delay Digital Adder Flicker-free Monitor!! WOW!! 40MHz Ultra-High frequency Sampling Rate MR Technology (Wide Aperture Technology) Target Probe Catch Axial, Lateral, and Temporal Resolution….

11 Wide Aperture Technology High Precision Digital Beamformer
Flicker-free Monitor ATO Axial Resolution 3CB(2-5MHz Probe) Lateral Resolution Auto Wave Shaping Best B-Mode IQ! Contrast Resolution Wide Aperture Technology Temporal Resolution 40MHz Converter High Precision Digital Beamformer

12 using One-Touch on keyboard
ATO Acoustic Data LOGIQ200MD PRO Image Processor Image ATO gives you the best contrast resolution using One-Touch on keyboard Image Analysis Optimization based on Digital Adaptive Processing

13 Less Operator Dependent… Faster... Better Image Quality
Conventional Manual Image Optimization 2-5 Minutes ROI In seconds ATO Less Operator Dependent… Faster... Better Image Quality

14

15 MVP Board NOVA BUS IMAGE STORAGE RAM FRAME AVERAGE XY MEMORY IMAGE
DISPLAY CONTROL IMAGE SOFTENER ALM ITP VIDEO LUT Video DAC CRDTF ZOOMER PEAK HOLD B/M FRONT END CONTROL XY ADDR GEN INTER LACE CONVERT NON-INT CONVERT VID DAC VIDEO DECODER CINE MEMORY CINE CONTROL SAP SYNC GENERATOR XY MEMORY FIFO USC BUS USC BUS I/F DSP PROGRAM MEMORY

16

17 CPU MSTE RESET ROM RTC SUPER I/O RAM VRAM AGDC IDE CTL FROM NOVA BUS

18

19 HV +/-100V +/- 65 V

20 LV Voltages From System

21 Password : Antony

22

23 Logic 200 Alpha Logic 200 Pro MST DSC MVP ESP RBF RTC TBF CONN SCAN
COMPARISION OF LOGIC 200 WITH 200 PRO Logic 200 Alpha Logic 200 Pro MST DSC MVP ESP RBF RTC TBF CONN SCAN HV unit BPHV UNIT MONITOR Non Interlace Monitor

24

25

26

27

28 Follow these steps to enter the Service Menu.
Note Probes should be installed in the port and Blue Shift key should be off before take these steps. 1. Pressing Shift + Ctrl keys and then press the Shift +s keys, and then Shift + 1 keys. 2. Input the PASSWORD and press Return key. The Service Top Menu will appear on the monitor as shown in ILLUSTRATION 2--5. Service Utility MENU : Top Menu 99/03/12 09:16:37 Current Software Version is 3.0 *System Diagnosis Board/Program Version System Reset Key Operation History Option Set Initialize :1 (1:America 2:Europe 3:Asia 4:Japan) System Clock Adjust Exit

29 TEST Conditions

30 Follow these steps to exit the Service Menu.
1. Press Shift + R keys. If this step will be performed again, the Service Menu will be entered again. OR 2. Select Exit on the Top Menu, and press Set or Return keys. The Service Menu will be exited. Follow these steps to operate the Service Menu. 1. Using Arrow Up/down keys, select one of seven items. 2. Press Set or Return keys. The Service Sub Menu will be appeared or Service Menu will be operated. Note Resetting the system using the System Reset, to reboot System, does not affect on the system presets.

31 Follow these steps to enter the System Diagnosis menu.
1. Using the Arrow up/down keys, select the “System Diagnosis”menu in the Top Menu. Refer to the ILLUSTRATION The left side of selected menu, here will be appeared the cursor (*). 2. Press Set or Return keys. The System Diagnosis menu will appear on the monitor as shown in the ILLUSTRATION 2--6. Service Utility MENU : System Diagnosis 99/03/12 09:16:37 Current Software Version is 3.0 NAME Time Status *System test 21 M Scan Test 0 M TBF Test 0 M Linear/Convex Path 0 M Sector Probe Path 0 M BPHV test 1 M MVP Hardware Test 1 M B mode Function 1 M B mode Cine 8 M M mode Function 2 M MSTE test 4 M Keyboard 0 M PIOP 1 M Monitor 0 M Power Supply 1 M Exit Press ’ctrl’+’X’to

32 Failure Codes

33

34

35

36 Wide Range of Probes CBF Convex Probe LB Linear Probe CAE Convex Probe
- Frequency:3.5Mhz - Bandwidth: Mhz -FOV:72deg -Convex ROC:50mmR -Biopsy guide: Available CAE Convex Probe -Frequency:5Mhz -Bandwidth: Mhz -FOV:72deg -Convex ROC:72mmR -Biopsy guide: Available LB Linear Probe -Frequency:3.5Mhz -Bandwidth: Mhz -FOV:94mm LE Linear Probe -Frequency:5.0Mhz -Bandwidth: Mhz -FOV:83mm LD Linear Probe -Frequency:3.5Mhz -Banswidth: Mhz -FOV:94mm MTZ Micro-Convex Probe -Frequency:6.5Mhz -Bandwidth: Mhz -FOV:124deg -Convex ROC:10mmR -Biopsy guide:Available

37 Wide Range of Probes

38 Wide Range of Probes ERB Micro convex/Linear Array probe
-Frequency : 7.0Mh -Bandwidth : Mhz -FOV : 12 deg 10L Linear probe -Frequency : 9.0Mhz -Bandwidth : Mhz -FOV : 40mm S317 Phased Array Sector probe -Frequency : 3.5Mhz -Bandwidth : Mhz -FOV : 90 deg 3Cb Convex Array Probe -Frequency : 3.5Mhz -Bandwidth : Mhz -FOV : 59 deg CS Microconvex Array probe -Frequency : 3.5Mhz -Bandwidth : Mhz -FOV : 81 deg