Download presentation
Published byLaurel Payne Modified over 9 years ago
1
Cardiac applications of 16 slice MDCT :Initial experience
Samsung Medical Center Dong-Joon Ahn
2
Purpose Applications of 16 slice MDCT in cardiac disease
To evaluate the effectiveness : CAC , CTA , Functional analysis
3
Materials & Equipments
CAC : 8 , CTA : 28 Lightspeed ultra 16 (GE) Advantage workstation version 4.0 (GE) Millenia 3500 CT ECG monitoring system (Invivo rsearch Inc.) Envision CT (Medrad) Iomeron 300 (Braco co.)
4
Calcium scoring I. Image acquisition II. Evaluation Method
No contrast material 2.5mm x 8i scan (cine mode) Gantry rotation time : 0.5sec Prospective ECG gating : 75% II. Evaluation Agatstone score
5
Coronary arteries angiography
Method Coronary arteries angiography I. Image acquisition Non-ionic CM ml, 4ml/s 0.625mm scan Gantry rotation time : 0.5sec Retrospective ECG gating Image reconstruction according to cardiac phases : % of RR interval II. Evaluation Compare 45%, 55% & 75% of RR interval
6
Reconstruction method & heart rate
H R Acquisition Mode Temporal Resolution 40~60 Snapshot Segment 250ms, 1cycle 60~75 Snapshot Burst 125ms, 2cycles 75~90 Snapshot Burst Plus 65ms, 4cycles
7
Reconstruction method
Snapshot segment mode Snapshot burst mode Snapshot burst plus mode
8
Post processing methods
Volume rendering Maximum intensity projection (MIP) Reformation in cardiac short and long axis Vessel analysis Endoscopic view (fly-through) Curved reformation
9
I. Calcium scoring Agatscore 0 in 4 14 in 1 55 in 1 821 in 1 928 in 1
Results I. Calcium scoring Agatscore 0 in 4 14 in 1 55 in 1 821 in 1 928 in 1
10
II.Coronary arteries angiography
Results II.Coronary arteries angiography Best phase locations for image quality 45% : RCA in 7, distal LAD in 5 55% : RCA in 1 75% : LAD in most patients and RCA in 2 good image quality in 33/36 (91%)
11
LAD: 75% = Best 45% 55% 75%
12
Phase location and image quality
55% 45% 65% 75%
13
Short and long axis of heart
14
Coronary vessel tree view
Volume rendering Coronary vessel tree view LIMA - SVG Artifact
15
Automatic MIP MPVR Curved reformation
16
Consideration Improved image reconstruction algorithm and software
Prospective or retrospective ECG gating Better temporal resolution Image acquisition of isotropic resolution
17
Limitations of coronary CTA
Extensive calcifications Stents : spatial resolution Variable heart rate : poor image quality Radiation dose Small branches / septal branches
18
Conclusion (I) Screening asymptomatic high risk population (CAC, CTA)
Exclusion of stenosis in patients with low likelihood of extensive disease Diagnosis in pts with atypical angina Post-procedural evaluation (CABG, stent) Plaque characterization Follow-up after drug treatment
19
Conclusion (II) The fast volume coverage of ECG gated 16 slice CT enables acquisition of the entire heart volume with nearly isotropic resolution within a single breath hold.
22
Hr
30
Cardiac CT EKG 동조화 Temporal resolution 향상 Isotropic resolution영상획득
Software
31
Cardiac function
32
Short and long axis of heart
33
Phase registration Before After
34
Vessel analysis
35
Volume rendering
36
Isotropic resolution영상획득
37
RCA Stent HR =
38
Y- graft :RITA-LAD, RITA-OM1-OM2-PL
39
45% volume rendering, HR: 75-84
Similar presentations