Presentation is loading. Please wait.

Presentation is loading. Please wait.

HI-FOG® Water Mist Fire Protection System

Similar presentations


Presentation on theme: "HI-FOG® Water Mist Fire Protection System"— Presentation transcript:

1

2 HI-FOG® Water Mist Fire Protection System
Safeguarding your building, detainees, your staff and the environment Minimising fire & smoke damages Keeping your prison running

3 Special Risks & Problems
The safety of the detainee is the responsibility of the authorities (you cannot leave the detainee in an untenable environment) The safety of the staff is the responsibility of the authorities (you cannot send guards into an untenable environment or ask them to open the cell without adequate precautions) The system should be vandal proof and provide no ligature points Prisons are typically overcrowded and need cells available An efficient, sustainable and safe solution is needed

4 Fires in prisons are difficult
Most fires are deliberately caused by detainees Detainees cannot escape from the fire The prison cell in a small confined space Most fires are set in a position which is difficult to attack (i.e. shielded fires, for example on the bottom bunk beds) Often, the detainees are agitated or violent Fires and prisoner injuries or deaths are widely reported

5 The Conundrum… You cannot just leave your detainees in their cell during a fire. You cannot just open the doors, you must follow procedures. You cannot send a guard into an untenable cell. The only course of action is to make the cell tenable during a fire, so that the detainee can remain in the cell until staff are prepared to rescue the detainees.

6 What is a Tenable Environment?
Typical figures set for prison tenability are: Maximum carbon monoxide (CO) concentration of 1,500 ppm Maximum carbon dioxide (CO2) concentration of 5% Oxygen (O2) concentration to stay above 14 % Maximum temperature 80°C These concentrations are limiting values that are immediately dangerous-to life or health and represent currently accepted values for these gases for exposures of a number of minutes, usually 30 minutes*. *The typical time for guards to be ready to effect the rescue is 15 minutes.

7 HI-FOG performance against the tenability criteria
In recent third party prison tests the following were measured: Maximum carbon monoxide (CO) concentration of 1,500 ppm PASS

8 HI-FOG performance against the tenability criteria
In recent third party prison tests the following were measured: Maximum carbon dioxide (CO2) concentration of 5% PASS

9 HI-FOG performance against the tenability criteria
In recent third party prison tests the following were measured: Oxygen (O2) concentration to stay above 14 % PASS

10 HI-FOG performance against the tenability criteria
In recent third party prison tests the following were measured: Maximum temperature 80°C PASS

11 The HI-FOG prison nozzle
HI-FOG® prison nozzle in normal position VANDAL PROOF WITH NO LIGATURE POINTS HI-FOG® prison nozzle in discharging position

12 Smaller is Better! Smaller tubes compared to traditional sprinklers, means smaller holes need to be drilled in walls. Smaller tubes compared to traditional sprinklers, means less weight of the system. Smaller water usage (typical 10 – 30% of traditional sprinklers) means smaller water storage tanks. Smaller water usage (typical 10 – 30% of traditional sprinklers) means less water damage in the cell.

13 Gas Driven Pump Units (GPU)
Flexibility in Design Prison systems can be driven by: Electric Pumps (SPU) Diesel Pumps (SPUD) Gas Driven Pump Units (GPU)

14 Flexibility in Design NS12 Section Valve Hydrant
Discharge can be activated: Manually at the section valve Automatically by fire detection system Automatically timed by fire detection system In a single cell In groups of cells System can be supplemented with hydrant system for manual extinguishment of the fire NS12 Section Valve Hydrant

15 What is HI-FOG® Water Mist?
Principle of operation Oxygen Unbreakable chain reaction Heat Combustibles Riski, että rahat menee hukkaan kun järjestelmä kielletään. HI-FOG® Provides efficient cooling as well as radiant heat blocking HI-FOG® Water mist evaporates efficiently thus providing local inerting at the heart of the fire

16 The Large Meaning of Small Droplets
Water Surface area Drop size (mm) Number of droplets Vaporisation ratio 10 1 1 1 1 1000 10 0,1 0,1 1,000,000 100 0,01 0,01 1,000,000,000 1000 0,003

17 HI-FOG® Water Mist in Real Life
Riski, että rahat menee hukkaan kun järjestelmä kielletään.

18 To Summarise With HI-FOG you can get gaseous penetration and space filling in 3D with the fire fighting agent. Without the downsides of gas based or conventional sprinkler systems Halvempi rakentaa madollista rakentaa maan alle jne vaikeisiin paikkoihin mihin ylipaine luukkuja ei vio laittaa

19 What Does HI-FOG Offer? Minimum Disturbance to Business Saved Money
Less Construction Work Fast & Easy Installation Minimized Fire and Water Damage to the Prison and Equipment Minimum Cell Downtime Better Personnel Safety Saved Money Minimum Disturbance to Business High Safety DAUKKIEN kanssa ehkä vähän kyseenalainen…

20 Where can HI-FOG® prison systems be used
From small holding cells to large prisons: Cells within police stations Cells within court facilities Detention centres Application processing centres Prisons Note! HI-FOG® water mist is not applicable only for the cells but all the other ancillary spaces can be protected as well. Electrical rooms, visiting areas, corridors, offices, communal areas, restaurants, kitchens, storage rooms, backup generator areas etc. Halvempi rakentaa madollista rakentaa maan alle jne vaikeisiin paikkoihin mihin ylipaine luukkuja ei vio laittaa

21 Turn-key deliveries Fewer headaches, lower costs
Traditional sprinkler as well as gas business may be highly fragmented Consultants, component manufacturers, suppliers, installers... Who is responsible? Marioff provides expert services for the whole system lifecycle System consultation and engineering Turnkey project management Production and installation Commissioning and training Maintenance, system upgrades and spare parts We ensure the quality of HI-FOG® systems and services

22 The Solution & Risk Elimination
The Continuity of Your Business, The Safety of Your Equipment & Infrastructure The Safety of Your Staff The Safety of Those in Your Care. Can Be Ensured By A High Pressure Water Mist System that is: Tested & Developed during the course of 16 years in 6000 fire tests Has the most patents of any other system world wide Has the most type approvals than any other system in the world Is provided by a well established and trusted partner that is the market and technology leader in the world

23 Further information Marioff Corporation Oy
Buildings and Construction Segment

24 Additional slides

25 HI-FOG® fire protection cycle
Safe to evacuate Water Mist High water surface area Safe for people Heat blocking Safe to access and extinguish High pressure High evaporation High cooling High penetration Powerful suppression Low fire damage Safe for property High water speed Low oxygen at the point of fire Gaseous 3D behaviour Low water damage Low water consumption Small water tanks Space for other use Supporting your business Quick installation Small piping

26 World’s leading water mist system specialist
Strong R&D Over 6000 full-scale fire tests Certificates of approval FM - Factory Mutual VdS - Verband der Schadenversicherer Det Norske Veritas Lloyd’s Register of Shipping American Bureau of Shipping Germanisher Lloyd Bureau Veritas Registro Italiano Navale Polish Register of Shipping Russian Maritime Register of Shipping Marine Safety Agency, United Kingdom Swedish National Maritime Administration Finnish National Board of Navigation Norwegian Maritime Directorate Danish Maritime Authority Directorate of Shipping of Iceland Malaysian Fire Services Department Maritime Safety Authority, New Zealand MELTT, France DGSMA, The Netherlands MMMMSCD, Greece Marine Board of Victoria, Australia Australian Maritime Safety Agency Transport Canada...

27 Marioff Corporation Oy
Marioff designs, manufactures and supplies high-pressure HI-FOG® water mist fire protection systems World's leading supplier of water mist fire protection systems Head office and production facilities in Finland Part of United Technologies Fire & Security

28 Global presence Marioff office Marioff distributor UTC Fire & Security

29 HI-FOG® components Sprinklers
State-of-the-art high precision component Designed and manufactured by Marioff Machined from brass or stainless steel Pendent or sidewall Multiple aesthetic options Stainless steel, gold, antique brass, RAL

30 HI-FOG® components Valves Pipes Designed and manufactured by Marioff
Machined from brass or stainless steel Corrosion and high pressure resistant Watertight connections with cutting rings Pipes Design and quality control by Marioff High pressure resistant Corrosion resistant stainless steel 316L Bendable to desired form and space Space efficient

31 HI-FOG® components Electrical motor driven high-pressure pump unit
Two pumps per motor External water and power supply Minimal water usage Typically l/min per sprinkler head Single pipe, single fluid Continuous, stable discharge Typically 80 bar pressure at the sprinklers Designed and assembled by Marioff Gas-driven high-pressure pump unit Double-action piston pump External water feed or water tank Self-contained, no external power supply Nitrogen or compressed air used as power source Typically 12 l/min per sprinkler head Single pipe, twin fluid (gas and water) Modular or integrated structure Designed, manufactured and assembled by Marioff Diesel driven high-pressure pump unit No need for external power supply Often built in a container

32 HI-FOG Testing in Prisons
Full Series of tests carried out with Buildings Research Establishment (BRE) in UK, and participation in BRE tests looking into the performance of various water based fire protection systems.