19F3A FFT PLC REHOST 20 NOVEMBER 2013 PDR – CDR PRESENTATION 1.

Similar presentations


Presentation on theme: "19F3A FFT PLC REHOST 20 NOVEMBER 2013 PDR – CDR PRESENTATION 1."— Presentation transcript:

1 19F3A FFT PLC REHOST 20 NOVEMBER 2013 PDR – CDR PRESENTATION 1

2 PRELIMINARY DESIGN REVIEW ENTRY CRITERIA Entry criteria for the PDR shall consist of Government concurrence with the following: a. SRR-II-SFR exit criteria have been met. b. CDRL items scheduled to be delivered prior to PDR have been delivered and accepted. c. Updated RTVM showing traceability of requirements IAW is available. d. Allocated baseline has been developed. e. Risk assessments and risk mitigation plans have been developed. f. R&M requirements have been allocated to the design. g. IMS shows critical path through Critical Design Review (CDR). h. Program technical risk is medium or lower. i. Program execution risk is medium or lower. j. PDR agenda has been submitted and accepted. 2

3 CRITICAL DESIGN REVIEW ENTRY CRITERIA Entry criteria for the CDR shall consist of Government concurrence with the following: a. PDR exit criteria have been met b. CDRL items scheduled to be delivered prior to CDR have been delivered and accepted. c. Updated RTVM showing traceability of requirements IAW is available. d. Product baseline has been developed. e. Updated Risk assessments and risk mitigation plans are available. f. Risk and their mitigation plans are in place and manageable for implementation of the functional requirements into a final design g. R&M requirements have been allocated to the design. h. Trade-off analyses have been completed i. Logistics analysis has been completed and plans have been established j. IMS show critical path through testing k. CDR agenda has been submitted and accepted 3

4 CURRENT CONFIGURATION INSTRUCTOR OPERATOR STATION 4 REHOST CONFIGURATION TRAINING SYSTEM MODIFICATIONS

5 IOS SIDE VIEW WITH NEW CONSOLE SCREEN COMPARED TO OLD CRT SCREEN INSTRUCTOR OPERATOR STATION 5 TRAINING SYSTEM MODIFICATIONS

6 LOWER PANEL CURRENT CONFIGURATION INSTRUCTOR OPERATOR STATION 6 TRAINING SYSTEM MODIFICATIONS LOWER PANEL REHOST UPGRADE

7 7 TRAINING SYSTEM MODIFICATIONS PRE-UPGRADE IOS AREA LAYOUT POST UPGRADE IOS AREA LAYOUT

8 COMPUTATIONAL SYSTEM 8

9 COMMUNICATION AND AUDIO SYSTEMS NO CHANGE 9

10 NETWORK GE PROFINET NETWORK 10

11 PROFINET Controller Specifications PROFINET SupportPROFINET Version 2.2 General Class A IO-Controller CPU CompatibilityRequires CPU315 or CPU320, with firmware version 7.0 or higher. Power Requirements 3.3V: 0.5 A with no SFP devices installed 1.2 A maximum (2 SFP devices installed, 0.35 A per SFP device) 5V: 1.5 A maximum Operating Temperature Range 0 to 60°C maximum surrounding air temperature without a fan. A lower maximum temperature may be required depending on PNC location and SFP population. Number of Port Connectors Two RJ-45 and Two SFP Cages (SFP devices not included, available separately.) Micro USB ConnectorOne, for communication with a computer using Command Line Interface. LAN IEEE Logical Link Control Class I IEEE CSMA/CD Medium Access Control 10/100/1000 Mbps Maximum I/O Memory128 Kbytes of combined input/output memory per PROFINET Controller CPU Status Bits32 PROFINET IO-Device Data Update Rates on the PROFINET Network Configurable: 1ms, 2ms, 4ms, 8ms, 16ms, 32ms, 64ms, 128ms, 256ms and 512ms 11

12 PROFINET Controller Specifications Number of IP addressesOne Number of MAC AddressesFive. One per external port and one internal. System Maximum Limits PROFINET Controllers per RX3i CPU4. Must be located in main rack. Cannot be located in a remote node. IO-Devices per IO-Controller 64 per PROFINET Controller at maximum update interval. For limits at shorter update intervals, refer to ―PNC Loading Limits‖ in chapter 3. IO-Devices per Network128 per network, spread across up to 8 IO-Controllers IO-Devices per RX3i CPU128 per RX3i CPU, spread across up to 4 PROFINET Controllers IO-Controllers per network8 Number of PROFINET Slots per device256 Number of PROFINET Subslots per slot256 Number of PROFINET Submodules per RX3i CPU2048 Programmer Limits Number of IO-Controllers128 (32 RX3i CPU targets × 4 IO-Controllers per RX3i CPU) Number of IO-Devices2048 (128 per network × 16 PROFINET networks) Total number of devices2176 (does not include backplanes, power supplies, or I/O modules) Hot-swappableYes 12

13 Basic System: One RX3i CPU and One PROFINET Controller using a single port Components of the RX3i PROFINET network consist of a PACSystems RX3i PNC module in the RX3i main rack communicating with IO Devices on the PROFINET bus. The main RX3i rack can include up to four PNCs, each communicating with its own high-speed network. IO Devices on the network can include VersaMax PNS modules and a wide range of third- party devices. For example, the illustration below shows a basic system with one PACSystems RX3i CPU node having one PNC, and one PROFINET network with three VersaMax Scanners and one third-party IO-Device. Up to 64 PROFINET Networks for PACSystems PROFINET is an open standard for industrial automation that is based on Industrial Ethernet. The PROFINET IO framework allows the creation of I/O data exchanges between controllers and distributed devices. It also allows configuration, parameterization, and diagnostics communication between controllers and devices. Note: The PROFINET Controller operates only in autonegotiate mode. All PROFINET bus devices and switches that are connected to the PROFINET Controller should be configured to use autonegotiation 13

14 INSTRUCTIONAL SYSTEM IOS SCREEN LAYOUT 14

15 COMP #1 O/S BILGE OPERATE POWER COMP #2 BILGE COMP #5 STORAGE COMP COMP #6 MATTRESS COMP #6 LOCKERS COMP #9 WEAPONS DISABLE PILOT MAIN PAUSE SMOKE VENTS BURN: ___ EXTG : ___ TOTAL: __ PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE SMOKE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOTSMOKE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOTSMOKE AUTO LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOTSMOKE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS LOCAL REMOTE BURN: ___ EXTG : ___ TOTAL: ___ BURN: ___ EXTG : ___ TOTAL: __ BURN: ___ EXTG : ___ TOTAL: ___ SMOKE AUTO SMOKE SYSTEM RESET PRINTER ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE LOCAL REMOTE REMOTE REMOTE REMOTE REMOTE IOS NORTH 13:56:24 11/20/2013 MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE 15

16 COMP #3 E/P OPERATE POWER COMP #3 DRYER COMP #4 WIRE BUNDLE COMP #4 FRYER/ HOOD COMP #7 VENT DUCT COMP #7 MTR GEN COMP #8 TRASH CAN COMP #8 RADAR CONSOLE PILOT PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOTSMOKE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o VENTS DORT COMP LAMP TEST MALF TRAINER STATUS BURN: ___ EXTG : ___ TOTAL: ___ BURN: ___ EXTG : ___ TOTAL: ___ SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE SYSTEM RESET PRINTER DISABLELOCAL REMOTEENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE LOCAL REMOTE REMOTE REMOTE REMOTE REMOTE DISABLE ENABLE DISABLE ENABLE LOCAL REMOTE REMOTE IOS SOUTH 13:56:24 11/20/2013 MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE 16

17 OPERATE POWER 17

18 COMP #1 O/S BILGE COMP #2 BILGE COMP #5 STORAGE COMP COMP #6 MATTRESS COMP #6 LOCKERS COMP #9 WEAPONS PILOT MAIN PAUSE SMOKE VENTS BURN: ___ EXTG : ___ TOTAL: __ PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE SMOKE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE SMOKE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE SMOKE AUTO LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE SMOKE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: ___ EXTG : ___ TOTAL: ___ BURN: ___ EXTG : ___ TOTAL: __ BURN: ___ EXTG : ___ TOTAL: ___ SMOKE AUTO OPERATE POWER TOUCH THE OPERATE POWER ICON. ICON BECOME LIGHTED AND OPERATE POWER IS PROVIDED TO THOSE FIREPLACES ASSIGNED TO THE CONSOLE. SMOKE SYSTEM RESET PRINTER DISABLELOCAL REMOTEENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE LOCAL REMOTE REMOTE REMOTE REMOTE REMOTE IOS NORTH 13:56:24 11/20/

19 COMP #1 O/S BILGE COMP #2 BILGE COMP #5 STORAGE COMP COMP #6 MATTRESS COMP #6 LOCKERS COMP #9 WEAPONS PILOT MAIN PAUSE SMOKE VENTS BURN: ___ EXTG : ___ TOTAL: __ PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE SMOKE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE SMOKE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE SMOKE AUTO LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT MAIN PAUSE SMOKE LOCAL REMOTE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: ___ EXTG : ___ TOTAL: ___ BURN: ___ EXTG : ___ TOTAL: __ BURN: ___ EXTG : ___ TOTAL: ___ SMOKE AUTO OPERATE POWER WHEN OPERATE POWER IS ENERGIZED, THE TRAINER SMOKE SYSTEM IS POWERED UP. THE SMOKE ICON FOR ALL FIREPLACES WILL FLASH AND LIGHT STEADY WHEN READY. SMOKE SYSTEM RESET PRINTER DISABLELOCAL REMOTEENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE LOCAL REMOTE REMOTE REMOTE REMOTE REMOTE IOS NORTH 13:56:24 11/20/

20 FIREPLACE AGENTS AND CONDITIONS LIST 20

21 COMP #1 O/S BILGE COMP #2 BILGE COMP #5 STORAGE COMP COMP #6 MATTRESS COMP #6 LOCKERS COMP #9 WEAPONS PILOTSMOKE [H20] [PKP] [AFFF] [HALON] VENTS BURN: ___ EXTG : ___ TOTAL: __ PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOTSMOKE LOCAL REMOTE [H20] [PKP] [AFFF] [HALON] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOTSMOKE LOCAL REMOTE [H20] [PKP] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT LOCAL REMOTE [H20] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOTSMOKE AUTO LOCAL REMOTE [H20] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOTSMOKE LOCAL REMOTE [H20] [AFFF] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: ___ EXTG : ___ TOTAL: ___ BURN: ___ EXTG : ___ TOTAL: __ BURN: ___ EXTG : ___ TOTAL: ___ VENT SEC VAL SEC - RFLSH TORCH - DIGGING RFLSH DIGGING SOAK DOOR OPEN CLTH RMD RFLSH SOAK VENT SEC VAL SEC - RFLSH TORCH - DIGGING SMOKE AUTO OPERATE POWER SMOKE SYSTEM RESET PRINTER DISABLELOCAL REMOTEENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE LOCAL REMOTE REMOTE REMOTE REMOTE REMOTE IOS NORTH 13:56:24 11/20/2013 MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE 21

22 COMP #3 E/P OPERATE POWER COMP #3 DRYER COMP #4 WIRE BUNDLE COMP #4 FRYER/ HOOD COMP #7 VENT DUCT COMP #7 MG SET COMP #8 TRASH CAN COMP #8 RADAR CONSOLE PILOT [H20] [C02] [PKP] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT [H20] [C02] [PKP] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT [H20] [C02] [PKP] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOTSMOKE [H20] [C02] [PKP] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT [H20] [C02] [PKP] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT [H20] [C02] [PKP] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT [H20] [PKP] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o PILOT [H20] [C02] [PKP] PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o VENTS DORT COMP LAMP TEST MALF TRAINER STATUS BURN: ___ EXTG : ___ TOTAL: ___ BURN: ___ EXTG : ___ TOTAL: ___ PWR SEC DR OPEN BELL RFLSH CAN REM SOAK RFLSH PWR SEC BELL RFLSH VNT SEC RFLSH SOAK PWR SEC APC – BELL RFLSH TORCH PWR SEC BELL RFLSH PWR SEC BELL - RFLSH DR OPEN VAL SEC PWR SEC BELL DR OPEN SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE AUTO SMOKE SYSTEM RESET PRINTER DISABLELOCAL REMOTEENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE DISABLE ENABLE LOCAL REMOTE REMOTE REMOTE REMOTE REMOTE DISABLE ENABLE DISABLE ENABLE LOCAL REMOTE REMOTE IOS SOUTH 13:56:24 11/20/2013 MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE MAIN PAUSE 22

23 FIREPLACE PARAMETER LIST 23

24 . COMP #1 O/S BILGE OPERATE POWER COMP #2 BILGE COMP #5 STORAGE COMP COMP #6 MATTRESS COMP #6 LOCKERS COMP #9 WEAPONS GROWTH 5-90 [ 5 ] SPREAD 5-90 [ 5 ] RFL GRTH 3-90 [ 3 ] RFL SPRD 3-90 [ 3 ] EXTINGUISH 3-90 [ 120 ] HALON ACT 1 NORM/MALF] VENTS ESCP TRUNK FULL / LOW GROWTH 5-90 [ 5 ] SPREAD 5-90 [ 5 ] SOAK [ 2 ] EXTINGUISH 3-90 [ 3 ] DORT COMP LAMP TEST HALON TIME DELAY NORM/MALF GROWTH 5-90 [ 5 ] SPREAD 5-90 [ 5 ] RFL GRTH 3-90 [ 3 ] RFL SPRD 3-90 [ 3 ] SOAK [ 2 ] GROWTH 5-90 [ 5 ] EXTINGUISH [ 120 ] FIRE START MODE [ R] [L ] [B] SPREAD 5-90 [ 5 ] FIRE START MODE [BL] [B] [BR] [R] [FR] [F] [FL] [L] MALF TRAINER STATUS EXTINGUISH 3-90 [ 120 ] SMOKE SYSTEM RESET PRINTER IOS NORTH 13:56:24 11/20/2013 HALON ACT 1 NORM/MALF] HALON ACT 2 NORM/MALF] HALON ACT 2 NORM/MALF] HALON TIME DELAY NORM/MALF FIXED REFLASH FIXED [ 10 ] REFLASH FIXED [ 5 ] GROWTH FIXED [ 6] FIREPLACE MODE OSBLG / BLG REFLASH FIXED [ 10 ] 24

25 COMP #3 E/P OPERATE POWER COMP #3 DRYER COMP #4 WIRE BUNDLE COMP #4 FRYER/ HOOD COMP #7 VENT DUCT COMP #7 MG SET COMP #8 TRASH CAN COMP #8 RADAR CONSOLE VENTS DORT COMP LAMP TEST SOAK [ 50 ] EXTINGUISH 2 – 60 [ 2 ] SOAK [ 2 ] HOOD EXTINGUISH 2 – 90 [ 90 ] SPREAD F → H [ 10 ] SPREAD H → F 3-15 [ 10 ] EXTINGUISH [ 25 ] FIRE START MODE [R>L] [L>R] [BOTH] RANGE GUARD [ MALF] [NORM] EXTINGUISH [ 60 ] SOAK [ 2 ] EXTINGUIS H [ 60 ] FIXED SOAK [ 2 ] EXTINGUISH [ 60 ] EXTINGUISH [ 60 ] MALF TRAINER STATUS SMOKE SYSTEM RESET PRINTER IOS SOUTH 13:56:24 11/20/2013 FIXED FIRE START MODE [FRYER] [FRYER>HD] [HD] [HD>FRYER] [FRYER+HD] FIXED 25

26 SETTING FIRE PLACE PARAMETERS FIRE FIGHTER TRAINER 26

27 THE SETTING OF EACH FIREPLACE IS IDENTICAL ONLY ONE FIREPLACE WILL BE USED TO DEMONSTRATE PROCEDURES 27

28 COMP #1 O/S BILGE OPERATE POWER PILOT MAIN PAUSE SMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: ___ EXTG : ___ TOTAL: __ TOUCH THE “FIREPLACE “ FOR WHICH THE PARAMETERS ARE TO BE CHANGED (OR VIEWED) SMOKE SYSTEM RESET PRINTER DISABLELOCAL REMOTEENABLE IOS NORTH 13:56:24 11/20/

29 COMP #1 O/S BILGE OPERATE POWER VENTS DORT COMP LAMP TEST MALF COMP #1 O/S BILGE GROWTH 5-90 [ 5 ] SPREAD 5-90 [ 5 ] RFL GRTH 3-90 [ 5 ] RFL SPRD 3-90 [ 5 ] EXTINGUISH 3-90 [ 5 ] HALON ACT 2 [ MALF ] ESCP TRUNK [ FULL ] HALON ACT 1 [ NORM ] TRAINER STATUS COMP TEMP 85 F o ALL AVAILABLE PARAMETERS FOR THE FIREPLACE CHOSEN WILL COME UP ON THE SCREEN ALONG WITH THE CURRENT SETTINGS. SMOKE SYSTEM RESET PRINTER IOS NORTH 13:56:24 11/20/2013 FIXED “FIXED” INDICATES THERE ARE PARAMETERS ASSIGNED TO THE FIREPLACE THAT CANNOT BE CHANGED. TOUCH THE FIXED ICON TO VIEW THESE PARAMETERS. 29

30 COMP #1 O/S BILGE OPERATE POWER VENTS DORT COMP LAMP TEST MALF COMP #1 O/S BILGE GROWTH 5-90 [ 5 ] SPREAD 5-90 [ 5 ] RFL GRTH 3-90 [ 5 ] RFL SPRD 3-90 [ 5 ] EXTINGUISH 3-90 [ 5 ] HALON ACT 2 [MALF ] ESCP TRUNK [ FULL ] HALON ACT 1 [ NORM ] TRAINER STATUS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o TOUCH THE PARAMETER THAT NEEDS TO BE CHANGED (GROWTH) SMOKE SYSTEM RESET PRINTER IOS NORTH 13:56:24 11/20/

31 COMP #1 O/S BILGE OPERATE POWER VENTS DORT COMP LAMP TEST MALF GROWTH SETTING [ 5 ] INCREASE +10 DECREASE ↓ TRAINER STATUS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o BURN: ___ EXTG : ___ TOTAL: ___ THE SETTING TOUCHED WITH ITS CURRENT SETTING AND PROGRAMMABLE RANGE IS DISPLAYED. SMOKE SYSTEM RESET PRINTER DECREASE -10 DECREASE INCREASE +1 IOS NORTH 13:56:24 11/20/

32 COMP #1 O/S BILGE OPERATE POWER VENTS DORT COMP LAMP TEST MALF GROWTH SETTING [ 50 ] TRAINER STATUS COMP TEMP 85 F o BURN: ___ EXTG : ___ TOTAL: ___ PROP LEVEL 0 %LEL 0 %LEL TO CHANGE THE VALUE, TOUCH INCREASE OR DECREASE VALUES UNTIL THE SET POINT IS REACHED AS YOU INCREASE OR DECREASE THE VALUE, THE SETTING VALUE CHANGES TO SHOW CURRENT SET POINT NOTE: A FIREPLACE CANNOT BE CHANGED OR SET OUTSIDE OF ITS PARAMETER RANGE SMOKE SYSTEM RESET PRINTER IOS NORTH 13:56:24 11/20/2013 INCREASE +10 DECREASE -10 DECREASE INCREASE +1 32

33 COMP #1 O/S BILGE OPERATE POWER VENTS DORT COMP LAMP TEST MALF GROWTH SETTING [ 50 ] INCREASE ↑ DECREASE ↓ TRAINER STATUS LOCAL REMOTE BURN: ___ EXTG : ___ TOTAL: ___ PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o WHEN THE SETTING HAS BEEN ACHIEVED, TOUCH THE PARAMETER ICON AGAIN SMOKE SYSTEM RESET PRINTER IOS NORTH 13:56:24 11/20/2013 INCREASE +10 DECREASE -10 DECREASE INCREASE +1 33

34 COMP #1 O/S BILGE OPERATE POWER VENTS DORT COMP LAMP TEST MALF COMP #1 O/S BILGE GROWTH 5-90 [ 50 ] SPREA D 5-90 [ 5 ] RFL GRTH 3-90 [ 5 ] RFL SPRD 3-90 [ 5 ] EXTINGUISH 3-90 [ 5 ] HALON ACT 2 NORM / MALF] ESCP TRUNK FULL / LOW HALON ACT 1 NORM / MALF] TRAINER STATUS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o OPERATOR RETURNED TO TOP PARAMETER SCREEN. NEW VALUE IS DISPLAYED. REPEAT THIS PROCESS FOR ANY PARAMETER THAT HAS TO BE CHANGED. WHEN CHANGES ARE COMPLETED, TOUCH THE FIREPLACE ICON AGAIN TO RETURN TO TOP SCREEN NOTE: THE OPERATOR CAN TOUCH THE FIREPLACE ICON AT ANY TIME WHILE CHANGING PARAMETERS AND BE IMMEDIATELY RETURNED TO THE TOP SCREEN. SMOKE SYSTEM RESET PRINTER IOS NORTH 13:56:24 11/20/2013 FIXED 34

35 COMP #1 O/S BILGE OPERATE POWER PILOTSMOKE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o TRAINER STATUS BURN: ___ EXTG : ___ TOTAL: __ VENTS DORT COMP LAMP TEST MALF SMOKE SYSTEM RESET PRINTER DISABLELOCAL REMOTEENABLE IOS NORTH 13:56:24 11/20/2013 MAIN PAUSE 35

36 BURNING A FIRE PLACE FIRE FIGHTER TRAINER 36

37 COMP #1 O/S BILGE OPERATE POWER ENABLE PILOTSMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT MALF TRAINER STATUS BURN: ___ EXTG : ___ TOTAL: __ TO ENABLE A FIREPLACE, THE OPERATOR TOUCHES THE ENABLE/DISABLE ICON. ENABLE WILL BECOME LIT NOTE: THERE IS NO TIME LIMIT FOR ENABLE. A FIREPLACE MAY STAY ENABLED ALL DAY. SMOKE SYSTEM RESET PRINTER COMP LAMP TEST DISABLE LOCAL REMOTE IOS NORTH 13:56:24 11/20/2013 MAIN PAUSE 37

38 COMP #1 O/S BILGE OPERATE POWER SMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS PILOT BURN: ___ EXTG : ___ TOTAL: __ THE OPERATOR TOUCHES PILOT. WHILE THE PILOT IGNITION SEQUENCE IS TAKING PLACE, THE PILOT ICON WILL BEGIN TO FLASH. WHEN ALL BURNERS HAVE COME TO PILOT, THE PILOT ICON WILL LIGHT STEADY. NOTE: IF NO ACTION IS TAKEN WITHIN 30 MINUTES, THE FIREPLACE WILL DISABLE ITSELF. SMOKE SYSTEM RESET PRINTER ENABLE DISABLE LOCAL REMOTE IOS NORTH 13:56:24 11/20/2013 MAIN PAUSE 38

39 COMP #1 O/S BILGE OPERATE POWER SMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS PAUSE BURN: 10 EXTG : ___ TOTAL: 10 THE OPERATOR TOUCHES MAIN. THE MAIN LIGHTS AND THE FIREPLACE WILL GROW AND SPREAD IN ACCORDANCE WITH THE PARAMETERS SET. BURN & TOTAL TIMER WILL START KEEPING TRACK OF TIME IN SECONDS SMOKE SYSTEM RESET PILOT ENABLE DISABLE MAIN PRINTER LOCAL REMOTE IOS NORTH 13:56:24 11/20/2013 NOTE: MAIN WILL FLASH FOR THE: DRYER, ELECTRICAL PANEL, STORAGE LOCKER, AND RADAR CONSOLE UNTIL THE DOOR IS OPENED. WHEN THE DOOR IS OPENED, MAIN WILL LIGHT STEADY AND THE FIRES WILL GROW AND SPREAD AS SET 39

40 COMP #1 O/S BILGE OPERATE POWER SMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: 15 EXTG : __ TOTAL: 15 IF SMOKE IS DESIRED, THE OPERATOR TOUCHES THE SMOKE ICON. THE SMOKE ICON LIGHTS TO SHOW SMOKE IS BEING EMITTED. NOTE: IF THE FIREPLACE HAS THE “AUTO” SMOKE FUNCTION – “AUTO” WILL ALSO APPEAR IN THE SMOKE ICON BELOW THE WORD SMOKE AND SMOKE EMANATION STARTS ONCE THE FIREPLACE IS IN PILOT. TOUCHING THE SMOKE ICON AGAIN WILL STOP THE SMOKING. THIS INCLUDE FIREPLACES WITH THE AUTO SMOKE SELECTED. SMOKE SYSTEM RESET PAUSE PILOT ENABLE DISABLE MAIN PRINTER LOCAL REMOTE IOS NORTH 13:56:24 11/20/

41 AGENT BEING APPLIED TO A FIREPLACE 41

42 COMP #1 O/S BILGE OPERATE POWER [H20]] VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: 45 EXTG : 30 TOTAL: 95 THE AGENT BEING APPLIED TO THE FIREPLACE IS DISPLAYED. EXTG TIMER BEGINS WHEN AGENT DETECTED SMOKE SYSTEM RESET SMOKE PAUSE PILOT ENABLE DISABLE MAIN PRINTER LOCAL REMOTE IOS NORTH 13:56:24 11/20/

43 COMP #1 O/S BILGE OPERATE POWER [H20]] [AFFF] VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: 65 EXTG : 50 TOTAL: 115 WHILE FIREPLACE IS BEING FOUGHT, ANY OTHER CONDITIONS WHICH TAKES PLACE PRIOR TO EXTINGUISHMENT WILL BE DISPLAYED DIGGING TORCH SMOKE SYSTEM RESET PRINTER SMOKE PAUSE PILOT ENABLE DISABLE MAIN LOCAL REMOTE IOS NORTH 13:56:24 11/20/

44 COMP #1 O/S BILGE OPERATE POWER SMOKE [H20] [C02] [PKP] [AFFF] VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS PILOT BURN: 80 EXTG : 90 TOTAL: 170 WHEN FIREPLACE PARAMETERS HAVE BEEN MET, THE FIRE EXTINGUISHES AND THE FIREPLACE IS DISABLED THE FIREPLACE CAN ALSO BE DISABLED AT ANY TIME BY TOUCHING ENABLE/DISABLE AGAIN THE BURN DATA IS SAVED AS A COMPLETED SCENARIO AND CAN BE PRINTED AT ANY TIME SMOKE SYSTEM RESET ENABLE DISABLE PRINTER LOCAL REMOTE IOS NORTH 13:56:24 11/20/2013 MAIN PAUSE 44

45 REMOTE OPERATION 45

46 COMP #1 O/S BILGE OPERATE POWER SMOKE LOCAL [H20] [C02] [PKP] [AFFF] VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS PILOT BURN: 40 EXTG : 120 TOTAL: 110 TO PASS CONTROL OF THE FIREPLACE TO THE COMPARTMENT, TOUCH LOCAL/REMOTE. REMOTE WILL BECOME LIGHTED ALL FUNCTIONS BEING ACTIVATED REMOTELY WILL BE DISPLAYED ON THE CONSOLE SCREEN NOTE: THE IOS OPERATOR HAS THE ABILITY TO TAKE CONTROL OF THE FIRE AT ANY TIME DURING A SCENARIO SMOKE SYSTEM RESET REMOTE PRINTER ENABLE DISABLE IOS NORTH 13:56:24 11/20/2013 MAIN PAUSE 46

47 47

48 COMP #1 O/S BILGE OPERATE POWER [H20]] [AFFF] VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: 65 EXTG : 50 TOTAL: 115 AT ANY TIME DURING THE SCENARIO THE PAUSE FUNCTION CAN BE USED - EITHER FROM THE IOS CONSOLE OR AT THE REMOTE OPERATOR STATION. WHEN TOUCHED, THE PAUSE FUNCTION ICON WILL BE LIGHTED. ALL GROWTH AND SPREAD FUNCTIONS CEASE AND THE BURN, EXTG, TOTAL TIMERS STOP COUNTING. TOUCH PAUSE AGAIN AND THE TRAINER SCENARIO RESUMES AND TIMERS CONTINUE. DIGGING TORCH NOTE: WHEN IN PAUSE, THE FIREPLACE WILL AUTOMATICALLY DISABLE ITSELF IF NO ACTION IS TAKEN WITHIN 100 SECONDS. SMOKE SYSTEM RESET PRINTER PAUSE ENABLE DISABLE MAIN LOCAL REMOTE SMOKE PILOT IOS NORTH 13:56:24 11/20/

49 COMPARTMENT TEMPERATURE READING FIRE FIGHTER TRAINER 49

50 COMP #1 O/S BILGE OPERATE POWER [H20] [C02] [PKP] [AFFF] VENTS PROP LEVEL 0 %LEL 0 %LEL TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: 40 EXTG : 120 TOTAL: 110 THE COMPARTMENT TEMPERATURES ARE DISPLAYED IN WBGT FORMAT. TO VIEW THE WET BULB, DRY BULB AND RADIANT HEAT READINGS, TOUCH THE COMP TEMP ICON DORT SMOKE SYSTEM RESET PRINTER PAUSE ENABLE DISABLE MAIN LOCAL REMOTE SMOKE PILOT IOS NORTH 13:56:24 11/20/

51 COMP #1 O/S BILGE OPERATE POWER [H20] [C02] [PKP] [AFFF] VENTS PROP LEVEL 0 %LEL 0 %LEL DRY 86F o WET 84F o GLOBE 85F o DORT COMP LAMP TEST MALF TRAINER STATUS BURN: 40 EXTG : 120 TOTAL: 110 DRY, WET AND GLOBE TEMPERATURES ARE DISPLAYED. TOUCH COMP TEMP AGAIN TO RETURN TO WGBT READING SMOKE SYSTEM RESET PRINTER PAUSE ENABLE DISABLE MAIN LOCAL REMOTE SMOKE PILOT IOS NORTH 13:56:24 11/20/

52 MALFUNCTION DISPLAY FIRE FIGHTER TRAINER 52

53 OPERATE POWER VENTS PRINTER DORT COMP LAMP TEST MALF TRAINER STATUS TRAINER MALFUNCTIONS A DISPLAY AREA WHEN A MALFUNCTION OCCURS, THE MALF ICON WILL FLASH TO ALERT THE OPERATOR OF A MALFUNCTION SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 BUILDING CONDITION DISPLAY AREA 53

54 OPERATE POWER VENTS DORT COMP LAMP TEST MALF TRAINER STATUS THE TRAINER STATUS LINE DISPLAYS THE CURRENT MALFUNCTION(S) SMOKE SYSTEM RESET NOTE: SHOULD A SITUATION OCCUR WHERE THERE ARE MORE MALFUNCTIONS THEN CAN BE DISPLAYED AT ONE TIME ON THE STATUS LINE - THE SCROLL FUNCTION ICON ENABLES THE IOS OPERATOR TO SCROLL UP OR DOWN TO VIEW ALL MALFUNCTIONS IOS NORTH 13:56:24 11/20/2013 FHM 6A65A3A5 TEMP OUT OF RANGE BCC 2A20 PILOT PROVED FAILURE PRINTER COMP #1 O/S BILGE [H20] [C02] [PKP] [AFFF] BURN: 40 EXTG : 120 TOTAL: 110 PAUSE ENABLE DISABLE MAIN LOCAL REMOTE SMOKE PILOT PROP LEVEL 0 %LEL 0 %LEL DRY 86F o WET 84F o GLOBE 85F o 54

55 OPERATE POWER VENTS PRINTER DORT COMP LAMP TEST MALF TRAINER STATUS TOUCH THE MALF ICON TO CLEAR STATUS LINE AND ACKNOWLEDGE MALFUNCTION(S) MALF LIGHT STOPS FLASHING, TRAINER STATUS LINE RETURNS TO NORMAL AND MALFUNCTION(S) ARE CLEARED AND RETAINED IN THE PRINT QUE. TO REVIEW ANY MALFUNCTIONS THAT HAVE BEEN CLEARED, TOUCH THE MALF ICON AGAIN TO VIEW THE QUE. TOUCH MALF AGAIN TO CLEAR THE SCREEN SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 COMP #1 O/S BILGE [H20] [C02] [PKP] [AFFF] BURN: 40 EXTG : 120 TOTAL: 110 PAUSE ENABLE DISABLE MAIN LOCAL REMOTE SMOKE PILOT PROP LEVEL 0 %LEL 0 %LEL DRY 86F o WET 84F o GLOBE 85F o 55

56 56

57 OPERATE POWER VENTS DORT COMP LAMP TEST MALF TRAINER STATUS PROP LEVEL 0 %LEL 0 %LEL SMOKE SYSTEM RESET NOTE: SHOULD A FOG HEAD MODULE FAIL DURING TRAINING, THE FOG HEAD WHICH FAILED WILL BE SHOWN IN THE TRAINER STATUS LINE AS PREVIOSLY DISPLAYED. WHEN A FOG HEAD MODULE DOES FAIL, THE SMOKE SYSTEM RESET ICON BECOMES BACK LIGHTED. RESETING THE SMOKE SYSTEM WILL ATTEMPT TO BRING THE FAILED FOG HEAD MODULE BACK ON LINE. THE SMOKE SYSTEM CAN ONLY BE RESET WHEN ALL FIREPLACES HAVE BEEN DISABLED. SHOULD ANY ATTEMPT TO RESET THE SMOKE SYSTEM BE MADE WHILE A FIREPLACE IS ENABLED, THE RESET ACTION IS IGNORED BY THE PLC SYSTSEM AND THE ABOVE NOTE IS TEMPORARLY DISPLACED IN THE TRAINER STATUS LINE. NOTE: ALL FIREPLACES MUST BE DISABLED TO RESET SMOKE SYSTEM IOS NORTH 13:56:24 11/20/2013 COMP #1 O/S BILGE [H20] [C02] [PKP] [AFFF] BURN: 40 EXTG : 120 TOTAL: 110 PAUSE ENABLE DISABLE MAIN LOCAL REMOTE SMOKE PILOT PRINTER PROP LEVEL 0 %LEL 0 %LEL DRY 86F o WET 84F o GLOBE 85F o 57

58 58

59 COMP #1 O/S BILGE PILOTSMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS BUILDING SHUTDOWNS ARE DISPLAYED IN THE BUILDING CONDITION AREA. EXAMPLE ONE: COMPARTMENT EMERGENCY STOP (NORTH SIDE ONLY EFFECTED) OPERATE POWER MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ WHEN AN E-STOP SWITCH IS PUSHED, THE CONDITION IS DISPLAYED IN THE TRAINER STATUS LINE ALONG WITH ITS LOCATION AND DESIGNATOR. VENTILATION DAMPERS OPEN TO FULL FLOW AND OPERATE POWER IS REMOVED ON THE SIDE OF THE TRAINER THE STOP WAS PRESSED. SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PRINTER ENABLE DISABLELOCAL REMOTE 59

60 COMP #1 O/S BILGE PILOTSMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER WHEN THE E-STOP IS RESET, “EMERGENCY STOP CLEARED” WILL APPEAR IN THE TRAINER STATUS LINE. AT THIS TIME THE 3 MINUTE AIR PURGE WILL BEGIN. MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 ENABLE DISABLELOCAL REMOTE PRINTER 60

61 COMP #1 O/S BILGE PILOTSMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ AT THE END OF THE 3 MINUTE AIR PURGE, “BUILDING READY” WILL BE DISPLAYED IN THE TRAINER STATUS LINE FOR 5 SECONDS AND THEN BE REMOVED. THE VENTILATION DAMPERS WILL RETURN TO NORMAL SETTING. OPERATE POWER CAN NOW BE RETURNED TO THE SIDE OF THE TRAINER THAT HAD BEEN SHUT DOWN. SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 ENABLE DISABLELOCAL REMOTE PRINTER 61

62 62

63 VENTS DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER DURING LIVE FIRE FIGHTING, THE TEMPERATURE IN THE COMPARTMENT CONTINUES TO INCREASE. PRIOR TO A HIGH TEMPERATURE SHUTDOWN, A HIGH TEMP WARNING WILL APPEAR IN THE TRAINER STATUS LINE. THIS WARNING ALLOWS THE CONSOLE OPERATOR TO INFORM THE FIELD SAFETY CHIEF OF AN EMANATE SHUTDOWN. THE FIREPLACE CAN BE RETURNED TO PILOT TO ALLOW FOR HEAT DISSIPATION - THEREBY AVOIDING A FULL SHUTDOWN AND DELAY OF TRAINER DUE TO 3 MINUTE AIR PURGE SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PRINTER [H20] [C02] [PKP] [AFFF] BURN: 40 EXTG : 120 TOTAL: 110 PAUSE ENABLE DISABLE MAIN LOCAL REMOTE SMOKE PILOT COMP #1 O/S BILGE PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o 63

64 VENTS DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER IF NO ACTION WAS TAKEN DURING THE HIGH TEMP WARNING, THE COMPARTMENT TEMPERATURE COULD CONTINUE TO RISE AND BECOME A HIGH TEMP SHUTDOWN WHICH WILL BE DISPLAYED IN THE BUILDING CONDITION AREA. VENTILATION DAMPERS WILL ALREADY BE IN FULL OPEN, BUT OPERATE POWER WILL BE REMOVED. SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PILOTSMOKE COMP TEMP 85 F o MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ ENABLE DISABLELOCAL REMOTE COMP #1 O/S BILGE PROP LEVEL 0 %LEL 0 %LEL PRINTER 64

65 VENTS DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER AS SOON AS THE TEMPERATURE DROPS 1 DEGREE BELOW THE SHUTDOWN SET POINT, SHUT DOWN CLEAR WILL APPEAR IN THE TRAINER STATUS LINE. THE 3 MINUTE AIR PURGE WILL BEGIN AT THIS TIME SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PILOTSMOKEMAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ ENABLE DISABLELOCAL REMOTE COMP #1 O/S BILGE COMP TEMP 249 F o PROP LEVEL 0 %LEL 0 %LEL PRINTER 65

66 VENTS DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER AT THE END OF THE 3 MINUTE AIR PURGE, “BUILDING READY” WILL BE DISPLAYED IN THE TRAINER STATUS LINE FOR 5 SECONDS AND THEN BE REMOVED. THE VENTILATION DAMPERS WILL RETURN TO NORMAL SETTING. OPERATE POWER CAN NOW BE RETURNED TO THE SIDE OF THE TRAINER THAT HAD BEEN SHUT DOWN. SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PRINTER PILOTSMOKEMAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ ENABLE DISABLELOCAL REMOTE COMP #1 O/S BILGE COMP TEMP 85 F o PROP LEVEL 0 %LEL 0 %LEL 66

67 67

68 COMP #1 O/S BILGE VENTS COMP TEMP 85 F o PROP LEVEL 7 %LEL 7 %LEL DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER BURN: ___ EXTG : ___ TOTAL: __ DURING A LIVE FIRE SCENARIO, THE LEVELS OF PROPANE IN THE CRAWL SPACE BENEATH THE FIREPLACE CAN INCREASE AS THE STUDENTS AGGRESSIVELY ATTACK THE FIRE. AS THE PROPANE LEVEL SLOWLY RISES IN THE CRAWL SPACE, AND PRIOR TO A HIGH PROPANE SHUTDOWN, A “HIGH PROPANE LEVEL WARNING” APPEARS IN THE BUILDING CONDITION STATUS AREA. THIS WARNING ALLOWS THE CONSOLE OPERATOR TIME TO NOTIFY THE FIELD SAFETY CHIEF OF AN EMANATE SHUTDOWN. THE ATTACK ON THE FIREPLACE CAN BE STOPPED, THEREBY AVOIDING A FULL PROPANE SHUTDOWN AND MANDATORY ENACTMENT OF THE FIRE SCHOOL “EMERGENCY ACTION PLAN” SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PRINTER PAUSE ENABLE DISABLE MAIN LOCAL REMOTE SMOKE PILOT 68

69 COMP #1 O/S BILGE PILOTSMOKE VENTS PROP LEVEL 10 %LEL 7 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ SHOULD A HIGH PROPANE CONDITION EXIST, “HIGH PROPANE LEVEL – BUILDING SHUT DOWN” APPEARS IN THE BUILDING CONDITION AREA. OPERATE POWER IS REMOVED FROM THE NORTH AND SOUTH SIDE OF THE TRAINER VENTILATION DAMPERS OPEN TO FULL POSITION SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PRINTER ENABLE DISABLE LOCAL REMOTE 69

70 COMP #1 O/S BILGE PILOTSMOKE VENTS PROP LEVEL 9 %LEL 2 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ WHEN THE LEVEL OF PROPANE DROPPED BELOW 10%LEL, SHUT DOWN CLEAR APPEARS IN THE BUILDING CONDITION AREA AND THE 3 MINUTE AIR PURGE BEGINS AT THIS TIME SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PRINTER ENABLE DISABLE LOCAL REMOTE 70

71 COMP #1 O/S BILGE PILOTSMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ AT THE END OF THE 3 MINUTE AIR PURGE, “BUILDING READY” WILL BE DISPLAYED IN THE BUILDING CONDITION AREA FOR 5 SECONDS AND THEN BE REMOVED. THE VENTILATION DAMPERS WILL RETURN TO NORMAL SETTING. OPERATE POWER CAN NOW BE RETURNED TO THE NORTH AND SOUTH SIDE OF THE TRAINER SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PRINTER ENABLE DISABLE LOCAL REMOTE 71

72 72

73 COMP #1 O/S BILGE PILOTSMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ THE PRINT ICON WILL BECOME BACK LIGHTED AS WILL THE MALF ICON AND THE PRINT FUNCTION FOR EACH FIREPLACE. PRINT ALL TO ENTER THE PRINT FUNCTION TOUCH THE PRINT ICON SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 ENABLE DISABLE LOCAL REMOTE PRINTER PRINT 73

74 PILOT SMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER COMP #1 O/S BILGE PRINT MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ TO PRINT A SINGLE FIREPLACE, TOUCH THE PRINT ICON. TO PRINT ALL EVENTS FROM THE TRAINING DAY TOUCH PRINT ALL. TO PRINT JUST THE MALFUNCTION SUMMARY, TOUCH MALF ICON PRINT ALL SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 ENABLE DISABLE LOCAL REMOTE PRINTER 74

75 COMP #1 O/S BILGE PILOTSMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS OPERATE POWER MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ TO EXIT THE PRINTER FUNCTION, TOUCH THE PRINTER ICON AGAIN SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PRINTER ENABLE DISABLE LOCAL REMOTE 75

76 76

77 19F3A FIRE FIGHTER TRAINER OTC NEWPORT RI TRAINER SCENARIO SUMMARY DATE: 24 AUGUST 2013 TIME: 1530 TIMECOMPPILOTMAIN AGENT SOAK TIME H2OCO2AFFFPKP 1 COMP TEMP F o 0952 O/S BILGE %LEL 0 %LEL BILGE %LEL 1 %LEL BILGE %LEL 1 %LEL NOTE: DISABLING A FIRE PLACE AND RE-ENABLING IT AGAIN AND BURNING CREATES TWO SEPARATE DATA ENTRY POINTS PROPANE LEL AND COMP TEMP READINGS ARE THE HIGHEST LEVELS ATTAINED DURING THE SCENARIO WWWW CH1CH2 PROPANE WBGT DRY WET GLOBE 77

78 19F3A FIRE FIGHTER TRAINER OTC NEWPORT RI TRG MALF – BLDG SHUTDOWN SUMMARY DATE: 22 JULY 2012 TIME: 1530 TIMETRAINER MALF / BLDG SHUT DOWN 0911TRAINER SHUTDOWNPROPANE MALFUNCTION 5A MALFLOW NITROGEN PRESSURE 2A MALF BUILDING LOW GAS PRESSURE 11A1 1023NORTH SHUTDOWNCOMPARTMENT HIGH TEMP 2A28 78

79 79

80 COMP #1 O/S BILGE OPERATE POWER SMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS PILOT MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ DURING NORMAL TRAINING OPERATIONS, THE CONSOLE OPERATOR HAS THE OPTION TO TURN THE VENTILATION ON OR OFF. IN THE 19F3A THE EXHAUST FANS MOTORS TURN ON WHEN THE TRAINER GOES TO RUN AND WILL SHUT OFF WHEN THE TRAINER IS PLACED IN 24 HOUR MODE. “VENTILATION” REFERS TO THE EXHAUST DUCT DAMPER GOING FROM A 40% REDUCED AIR FLOW TO 100% FULL FLOW SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 ENABLE DISABLE LOCAL REMOTE PRINTER 80

81 81

82 COMP #1 O/S BILGE OPERATE POWER SMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS PILOT MAIN PAUSE BURN: __ EXTG : __ TOTAL: __ THE DAILY OPERATIONAL READY TEST (DORT) IS PART OF “COMS” MORNING READINESS TEST. THE DORT FUNCTION ENABLES, PILOTS AND MONITORS ALL FIREPLACES ON THE SIDE OF THE TRAINER INITIATING THE DORT. AT THE END OF THE DORT ANY HARDWARE OR IGNITION MALFUNCTIONS THAT MAY HAVE OCCURRED ARE DISPLAYED IN THE TRAINER STATUS LINE. PILOT SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 PRINTER ENABLE DISABLE LOCAL REMOTE 82

83 COMP #1 O/S BILGE OPERATE POWER SMOKE VENTS PROP LEVEL 0 %LEL 0 %LEL COMP TEMP 85 F o DORT COMP LAMP TEST MALF TRAINER STATUS PILOT MAIN PAUSE BURN: ___ EXTG : ___ TOTAL: __ THE COMPARTMENT LAMP TEST IS PART OF THE “COMS” MORNING READINESS TEST. TOUCHING THE COMPARTMENT LAMP TEST ICON CAUSES THE FUNCTION LAMPS AT THE REMOTE OPERATOR STATIONS TO ILLUMINATE TO VERIFY NO BULB HAS BURNT OUT. SMOKE SYSTEM RESET IOS NORTH 13:56:24 11/20/2013 ENABLE DISABLE LOCAL REMOTE PRINTER 83

84 SOFTWARE TOOLS The Laptop specified for Software Development and maintenance is a Dell Inspiron 17” non-touchscreen with an Intel™ Core© I3 processor, 4 GB of RAM and a 500 GB hard drive. The Laptop will be loaded with Windows 7 and Proficy™ Machine 8.0. The Laptop can be utilized to perform three different software functions: 1. The initial cold start procedures. 2. Backup and restoration of the system software. 3. Modification of existing software and development of new software. Additionally, the Laptop can be utilized to dynamically troubleshoot the system. 84

85 COMMERCIAL AND NON-DEVELOPMENTAL (CaNDI) SOFTWARE AND DATABASES The software utilized to convert the Ladder Network is a proprietary utility developed by General Electric Intelligent Platforms (GEIP). This software was developed by GEIP for the sole purpose of converting Legacy Ladder Network software to run on new generation hardware. All other software utilized on this project is un-modified Commercial Off-The-Shelf. 85

86 COMP 1 O/S BILGE GROWTH [ 5 ] SPREAD [ 5 ] EXTINGUISH [120] REFLASH GROWTH [ 3 ] REFLASH SPREAD [ 3 ] HALON ACTUATOR NORMAL HALON TIME DELAY NORMAL MODE START OS/BILGE ESCAPE TRUNK FULL TORCH GROWTH FIXED - 1 TORCH RECEDE FIXED - 4 REFLASH FIXED - 15 COMP 2 - NORTH IOS BILGE GROWTH [ 5 ] SPREAD [ 5 ] EXTINGUISH [120] REFLASH GROWTH [ 3 ] REFLASH SPREAD [ 3 ] HALON ACTUATOR NORMAL HALON TIME DELAY NORMAL TORCH GROWTH FIXED - 1 TORCH RECEDE FIXED - 4 REFLASH FIXED - 15 COMP 5 - NORTH IOS STORAGE COMP GROWTH [ 5 ] SPREAD [ 5 ] SOAK [2] EXTINGUIS H [120] REFLASH FIXED - 10 COMP 6 - NORTH IOS MATTRESS SOAK [ 2 ] EXTINGUIS H [120] GROWTH FIXED - 6 REFLASH FIXED - 5 COMP 6 - NORTH IOS STORAGE LOCKER SOAK [ 2 ] EXTINGUIS H [120] MODE START R & L REFLASH FIXED - 10 COMP 9 - NORTH IOS DECK GROWTH [ 5 ] SPREAD [ 5 ] EXTINGUISH [120] START MODE BACK IOS NORTH DEFAULT PARAMETERS TRAINER DATABASES 86

87 IOS SOUTH DEFAULT PARAMETERS COMP 3 - CLOTHS DRYER SOAK [15] EXTINGUISH [60] FLASH-OVER GROWTH FIXED - 5 FLASH-OVER HIGHFIRE FIXED - 5 REFLASH FIXED - 5 COMP 3 - ELECTRICAL PANEL EXTINGUISH [50] REFLASH FIXED-15 COMP 4 - SOUTH IOS FRYER / HOOD SPREAD H>F 10 F>H 10 HOOD EXTINGUISH [90] RANGE GRD NORMAL MODE START F & H FRYER REFLASH FIXED - 30 HOOD REFLASH FIXED - 30 FRYER GROWTH FIXED - 4 FRYER REFLASH GROWTH FIXED - 4 FRYER TORCH GROWTH FIXED - 1 FRYER TORCH RECEDE FIXED - 5 FRYER EXTINGUISH FIXED - 3 COMP 4 - SOUTH IOS WIRE BUNDLE REFLASH FIXED-15 MODE START BOTH SCND START FIXED-120 COMP 7 - SOUTH IOS VENT DUCT SOAK [ 2 ] EXTINGUISH [90] REFLASH FIXED - 5 COMP 7 - SOUTH IOS MG SET EXTINGUISH [50] REFLASH FIXED - 15 COMP 8 - SOUTH IOS RADAR CONSOL EXTINGUISH [50] REFLASH FIXED - 15 COMP 8 - SOUTH IOS TRASH CAN SOAK [ 2 ] EXTINGUISH [60] GROWTH FIXED - 30 REFLASH FIXED - 5 TRAINER DATABASES 87

88 SOFTWARE DEVELOPMENT Overview Series Six source program files are the basis for the system software conversion to a PAC RX3i system Proficy Machine Edition. There are multiple steps that must be accomplished to arrive at a valid PAC systems PLC project. First, a program listing derived from the Series 6 source files must be produced. Then the source file is used as input to a program conversion utility. The utility generates a new mapping of the I/O references and additionally creates a script file. The script is executed in logicmaster90 to produce a ladder logic program for either a model or model PLC platform. Then the resulting program is imported into the target of a Proficy Machine Edition project. Finally, the Proficy Machine Edition target’s logic is manually inspected, validated against the original Series 6 program listing, and corrected if necessary. 88

89 As we discussed earlier, the conversion utility renders a fairly faithful rendition of the Series 6 ladder logic converted to equivalent RX3i ladder logic. As pointed out in the conversion document, there are a few special cases in which manual interventions are required. We will not attempt to modify the converted logic in terms of existing functionality. The only two exceptions to this being : - The new propane detection system (in which the %LEL values are received as analog input values instead of serial data inputs) - The deletion of the Air Quality Monitoring System inputs. However, we probably will need to remap some of the internal references for the purpose of HMI data linkages. SOFTWARE DEVELOPMENT 89

90 HARDWARE AND SOFTWARE INTERFACES Propane Detection System The Propane Detection System (PDS) is comprised of 10 cabinets (one in Compartments 1-8 and two in Compartment 9) with two Smartmax II gas detection systems in each cabinet. Figure 1 is a print of one new Propane Detection System (PDS) cabinet. Each PDS cabinet has two input signals and five output signals. Table 1 is a list of the PDS signals, their descriptions, and their possible values. z Compartment x Level 1 Compartment x Level 2 (Note: x = 1 – 9) (Note: Compartment 9 has 4 inputs) Analog Input developed across a 250Ω resistor mA Propane Level reading from Compartment x Smartmax #1, #2 (Note: And #3 & #4 in Compartment 9) Dynamic signal. When developed over a 250Ω resistor: VDC = 0% LEL 3.05 VDC = 50% LEL AutocalDigital Output When true causes all Smartmax II’s to Enter Auto Calibration mode. True = Ground False = float Compartment x Flow 1 Compartment x Flow 2 (Note: x = 1 – 9) (Note: Compartment 9 has 4 inputs) Digital Input Indicates there is flow provided by the Vacuum Pump in each Propane Cabinet for each Smartmax #1, #2 True = Ground False = float PropaneFailDaisy chain loop. When broken indicates one or more Smartmax II in Failed or True = float False = Ground Table 1: Propane Detection System Signals 90

91 HARDWARE AND SOFTWARE INTERFACES The 20 Compartment x Level 1 (2, 3 or 4) 4 – 20 mA signals will be connected to the electronic enclosure located in the corresponding compartment. A 250Ω resistor will be placed across the input to develop the input voltage to the Analog Input channel. The program will read the value and display the converted % LEL value on the appropriate block on the HMI display. The Autocal Digital Output signal is supplied by electronic enclosure 10A3A4 to each of the 10 PDS cabinets. When the Autocal signal is true (Ground) all 20 Smartmax II gas detection systems will enter the Autocalibration Mode. During Autocal Mode, calibrated concentrations of zero (0% propane in air) and propane gas (1.1% propane in air which equals 50% LEL) are automatically applied to the Smartmax II gas detection systems. The 20 Compartment x Level 1 (2, 3 or 4) 4 – 20 mA signals and the 20 Compartment x Flow 1 (2, 3 or 4) Digital Input signals are monitored for proper operation during this time. Additionally, The 20 Compartment x Level 1 (2, 3 or 4) 4 – 20 mA signals are displayed on the HMI displays along with the message “PROPANE CALIBRATION IN PROGRESS” in the Trainer Status block. The 20 Compartment x Flow 1 (2, 3 or 4) Digital Input signals will be connected to the electronic enclosure located in the corresponding compartment. 91

92 92 HARDWARE AND SOFTWARE INTERFACES When true (Ground), they indicate that there is flow provided by the Vacuum Pump in each Propane Cabinet for each of the two sample draw units in the PDS cabinet. The Propane Fail signal is daisy chained through all of the Smartmax II’s internal Fail and Alarm relays normally closed contacts. If one or more of the Smartmax II enters a Fail state the Fail Relay in the Smartmax II will energize and break the loop. If one or more of the Smartmax II’s has a reading of 20% LEL or greater it will enter an Alarm state and the Alarm Relay will energize and break the loop. This daisy chains primary function is in the 24 hour mode since dynamic reading of the PDS is inactive in 24 Hour mode. ESP has fabricated a complete fully functional mockup of the new PDS cabinet as it will be configured after the modification to the current cabinets. ESP plans to ship the cabinet to GEIP’s facility to aid in development, integration and testing.

93 HARDWARE AND SOFTWARE INTERFACES 93

94 HARDWARE AND SOFTWARE INTERFACES Air Quality Monitoring System The two potentiometers will be removed from cabinet 10A3. All Ladders involved with the Air Quality Monitoring System will be modified to remove actions. 94

95 PLC EQUIPMENT BEING REPLACED SERIES SIXSERIES ONEELECTRONIC ENCLOSURES 95

96 PLC EQUIPMENT BEING REPLACED INSTRUCTOR OPERATING STATIONS & ASSOCIATED EQUIPMENT IOS CONSOLES WORKMASTER STATION & PRINTER HEADS UP DISPLAY 96

97 OBSOLETE PROPANE MONITORING SYSTEM DATAMAX 1600 REMOVED XTR001 TRANSMITTERS REMOVED SENSOR CABINET - MINOR CHANGES- NEW SMARTMAX II TRANSMITTERS BEING INSTALLED 97

98 OTHER OBSOLETE TRAINER FIRE PLACE EQUIPMENT PKP SENSOR AMPLIFIERMODUTROL MOTOR NEW PKP SENSOR AMPLIFIER WATER SENSOR AMPLIFIER NEW WATER SENSOR AMPLIFIER NEW MODUTROL MOTOR 98

99 DESIGN MODULARITY AND COMMONALITY 99

100 FACILITY PLANNING NO CHANGES TO THE FACILITY 100

101 E 3 IMPACT 101

102 E 3 IMPACT 102

103 RELIABILITY AND MAINTAINABILITY THE NEW EQUIPMENT SELECTED TO REPLACE THE OBSOLETE EQUIPMENT IN THE 19F3A FIRE FIGHTER TRAINER IS: 1. MORE ECONOMICAL AND EFFICIENT 2. EASIER TO REPLACE/REPAIR 3. READILY AVAILABLE FROM MULTIPLE VENDORS 4. INDUSTRIAL GRADE AND RELIABLE 103

104 LOGISTICS DESIGN ASPECTS AND CONCERNS EQUIPMENTPART NUMBERMANUFACTURER PLANNED OBSOLESCENCE PREDICTED OBSOLESCENCE GE PROPHECY SOFTWARE 7.0VERSION 7.0GENERAL ELECTRICACTIVE MATURE +15 QUICK PANEL 15" TOUCH SCREENIC754VSF15CTDGENERAL ELECTRIC ACTIVE MATURE +15 BLANK FILLER PLATEIC694ACC310GENERAL ELECTRIC ACTIVE MATURE +15 INPUT MODULE, ANALOGIC694ALG221GENERAL ELECTRIC ACTIVE MATURE +15 INPUT MODULE 120VACIC694MDL240GENERAL ELECTRIC ACTIVE MATURE +15 OUTPUT MODULE 120VACIC694MDL340GENERAL ELECTRIC ACTIVE MATURE +15 INPUT MODULE 24VDCIC694MDL645GENERAL ELECTRIC ACTIVE MATURE +15 INPUT MODULE 24VDCIC694MDL660GENERAL ELECTRIC ACTIVE MATURE +15 OUTPUT MODULE 12/24VDCIC694MDL741GENERAL ELECTRIC ACTIVE MATURE +15 OUTPUT MODULEIC694MDL930GENERAL ELECTRIC ACTIVE MATURE +15 HD TERM BLOCK - 36 CONNECTORIC694TBB132GENERAL ELECTRIC ACTIVE MATURE +15 THERMOCOUPLE INPUT MODULEIC695ALG312GENERAL ELECTRIC ACTIVE MATURE SLOT UNIVERSAL BASEIC695CHS012GENERAL ELECTRIC ACTIVE MATURE SLOT UNIVERSAL BASEIC695CHS016GENERAL ELECTRIC ACTIVE MATURE +15 SERIAL COMMUNICATION MODULEIC695CMM002GENERAL ELECTRIC ACTIVE MATURE +15 CPU MODULE,IC695CPE305GENERAL ELECTRIC ACTIVE MATURE +15 ETHERNET MODULEIC695ETM001GENERAL ELECTRIC ACTIVE MATURE +15 ETHERNET KITIC695NKT001GENERAL ELECTRIC ACTIVE MATURE +15 POWER SUPPLY IC695PSA140GENERAL ELECTRIC ACTIVE MATURE +15 LAPTOPTBDDELLTBD PRINTERTBD 104

105 LOGISTICS DESIGN ASPECTS AND CONCERNS EQUIPMENTPART NUMBERMANUFACTURER PLANNED OBSOLESCENCE PREDICTED OBSOLESCENCE MODUTROL MOTORM6184D1035HONEYWELLN/P+10 YEARS SMARTMAX IISMX2ACCONTROL INSTRUMENTSN/P+10 YEARS SMARTMAXII MODULEPRB275CONTROL INSTRUMENTSN/P+10 YEARS FLAME SAFE GUARDRM7890A1056HONEYWELLN/P+10 YEARS FLAME AMPLIFIERR7847A1033HONEYWELLN/P+10 YEARS FSG BASE PLATEQ7800B1003HONEYWELLN/P+10 YEARS FSG CSD DISPLAYS7800A1142HONEYWELLN/P+10 YEARS BLOWER MOTOR3M777DGRAINGERN/P+10 YEARS SENSOR RELAY 120 BOARDD42854L&G TECHNOLOGIESN/P+10 YEARS WATER SENSOR / 21 SENSORD28955L&G TECHNOLOGIESN/P+10 YEARS SENSOR 120 CABLED23277L&G TECHNOLOGIESN/P+10 YEARS INFRARED PKP RELAYS142ARNN115CARLO GAVAZZI INCN/P+10 YEARS MKFR-M14-8 RECEIVER CARLO GAVAZZI INCN/P+10 YEARS MKFT15 TRANSMITTER CARLO GAVAZZI INCN/P+10 YEARS SOCKET RELAYSR39-05CIDEC COMPANYN/P+10 YEARS 105

106 PARTS MANAGEMENT PROGRAM PROGRESS AND IDENTIFICATION OF LONG LEAD TIME 1.PLC UPGRADE EQUIPMENT: ORDERED & AVAILABLE FOR DELIVERY WHEN REQUIRED 2.PROPANE UPGRADE EQUIPMENT SHIPPED 11/15 3.WATER SENSOR UPGRADE EQUIPMENT – IN MANUFACTURING – EST DLVY 12/20 4.PKP UPGRADE EQUIPMENT RECEIVED – BEING INSTALLED NOW 5.MODUTROL MOTORS RECEIVED 6.BLOWER MOTORS RECEIVED AND INSTALLED 106

107 COMMAND UID Compliancy Overview 107

108 What is UID? Strategic purpose Integrate item data across government and industry asset management systems, resulting in: Improved data quality and global interoperability Rationalization of systems and infrastructure Improve item management and accountability Improve asset visibility and life-cycle management through life cycle traceability Enable more accurate audit opinions on the property, plant, and equipment and operating materials and supplies portions of financial statements UID is the set of data for tangible assets that is globally unique and unambiguous, ensures data integrity and data quality throughout life, and supports multi-faceted business applications and users. EID Original Part Number 1234 Serial Number EID Original Part Number 1234 Serial Number EID Original Part Number 1234 Serial Number For DoD Information 2D matrix is to be marked on the item, UID is a single concatenated number structured either as construct #1 or #2

109 The UII Is Derived From Discrete Component Data Elements – The UII Is Not Required To Be Marked On The Item as Its Own Data Element Enterprise Identifier = 1DNT4 (CAGE Code) Original Part Number= 1234 Serial Number= 674A36458 Coded in the Data Matrix: The ISO assigned Issuing Agency Code (IAC) can be derived using the Enterprise data qualifier. The IAC for CAGE, is “D”: UII Construct 1UII Construct 2 If the Serial Number is Unique within the Enterprise Identifier If the Serial Number is Not Unique within the Enterprise Identifier but is Unique within the Part Number D1DNT4674A36458D1DNT A36458 ROB LEIBRANDT Unique Item Identification - How Is It Done? 109

110 Rules: Create and Generate the UII The components that make up the UII are identified in the table below. Each enterprise has two options for creating the UII. 110

111 Associated data (2.0 Schema) 1) Unique item identifier type 2) Unique Identifier Consisting of – Concatenated DoD unique item identifier – DoD recognized unique identification equivalent 3) Issuing agency code 4) Enterprise Identifier 5) Original part number 6) Serial Number 7) Contractor DUNS Number 8) Contract number 9) Contract line, sub-line or exhibit line item Ship to code 10) Item Description 11) Foreign Currency Code 12) Unit of Measure 13) Acquisition Cost (top level unit only) 14) Acceptance Code 15) Acceptance/Shipment Date 16) Ship To Code 17) Batch/Lot 17 data elements associated with each part will be supplied to the Prime Contractor (format determined by Prime) DoD schema updates will add more fields as DFARs are released 111

112 What items require UID? 112

113 What Is COMMAND ? Contractor Operations and Maintenance Management Database (COMMAND) Commercial Off The Shelf Architecture (COTS) requiring minimal I.T. oversight Complete Depot / Maintenance Management Database Performing all of the functions of the paper Visual Information Display System (VIDS)/ MAF system Tracks supply inventory and utilization using MIL-STD-130 compliant barcodes Automatically updates site inventory when parts are expended or added via entry screen input Tracks maintenance actions, both corrective and preventive Provides failure data history Electronic Logbook function Collects monthly trainer and hours data for Site Managers to prepare SOW and CDRL reports. Able to be customized for each “business unit’s” requirements COMMAND will remain current with Mil-Std 130 requirements UID data management system – history and tracking Outputs files for transfers to WAWF and submittals to UID Registry 113

114 Enterprise Identifier = 1DNT4 (CAGE Code) Original Part Number= 1234 Serial Number= 674A36458 Compliancy with COMMAND: UID REGISTRY UII Construct 1UII Construct 2 If the Serial Number is Unique within the Enterprise Identifier If the Serial Number is Not Unique within the Enterprise Identifier but is Unique within the Part Number D1DNT4674A36458D1DNT A

115 Application Approach COMMUNICATEREADMARK Symbology Verification Reading Mobile Computing MARKVERIFYREADCOMMUNICATE 115

116 TEST AND EVALUATION 116 Pre-Modification Testing Testing will be conducted to establish a baseline of Device 19F3A before the modification. This will include running the existing Trainer Test Procedures and Results Report (TTPRR) and performing a Physical Configuration Audit (PCA) in accordance with the Integrated Master Schedule (IMS). -Baseline Testing 11DEC13 thru 22JAN14

117 117 TEST AND EVALUATION Development Testing Testing will be conducted on the New PLC equipment at the General Electric Intelligent Platforms (GEIP) site in Charlottesville, VA in three phases in accordance with the IMS. Phase 1 will be a system checkout of the entire new hardware to ensure proper operation conducted by ESP and GEIP personnel. -Phase 1: 6JAN14 thru 10JAN14 Phase 2 will be a functional checkout of the entire new hardware to ensure proper operation of the HMI screens and the Propane Detection System conducted by ESP and GEIP personnel. -Phase 2: 13JAN14 thru 17JAN14 Phase 3 will be a functional checkout of the entire new hardware to ensure proper operation of the HMI screens and the Propane Detection System conducted by ESP, GEIP and government personnel. -Phase 3: 27JAN14 thru 31JAN14

118 118 TEST AND EVALUATION Post-Modification Testing Testing will be conducted to on the New PLC equipment installed on Device 19F3A at Newport, Rhode Island in four phases in accordance with the IMS. Phase 1 will be a system checkout of the entire new hardware to ensure proper operation conducted by ESP and GEIP personnel. -Phase 1: 23APR14 thru 27APR14 Phase 2 will be the Contractor TTPRR utilizing the new TTPRR (submitted as CDRL A002) conducted by ESP and GEIP personnel. -Phase 2: 28APR14 thru 2MAY14 Phase 3 will be the Government TTPRR utilizing the new TTPRR (submitted as CDRL A002) conducted by Government personnel. -Phase 3: 5MAY14 thru 9MAY14 Phase 4 will be the Government PCA conducted by Government Personnel. -Phase 4: 12May14 thru 14MAY14 All testing shall be governed by the Governments Test and Evaluation Management Plan (TEMP).

119 PROGRAM PROBLEM AND RISK ASSESSMENT Risk No.19F3A Likelihoo d Technica l Schedul e Cos tRisk Mitigation 1 GE fails to produce on time 3241 The Device will remain intact until a successful TTPRR has been run at the factory. ESP will work closely with GE to ensure the project stays on schedule. Cost is low since GE has quoted a Firm Fixed Price for software conversion/development. 2 New PLC system is damaged during shipment 2122 ESP will package the equipment using best available commercial packaging. ESP will insure the shipment to cover replacement cost. 3 Facility unavailable for installation. IE: Loss of power, Act of God 2133 ESP does not anticipate this risk at this time. We will work with the on-site COR to provide all maintenance necessary as the COMS contractor to expedite any unavailability. 4 Installation of the New Propane Monitoring System 2122 Modify/Rebuild existing draw sample cabinets to receive the SmartMax II propane monitors. 5Wire run removal2232Remove obsolete wire runs from trainer. Potential issue of wires being wrapped and stretching/breaking good wire runs. LOWHIGHMED 119

120 REQUIREMENTS TRACEABILITY VERIFICATION MATRIX (RTVM) 120