CUMMINS CONFIDENTIAL HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project Team Members: Kaela Hlaulani Prince Bedell William.

Similar presentations


Presentation on theme: "CUMMINS CONFIDENTIAL HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project Team Members: Kaela Hlaulani Prince Bedell William."— Presentation transcript:

1 CUMMINS CONFIDENTIAL HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project Team Members: Kaela Hlaulani Prince Bedell William Broaddus Derek Vleck Trever Zike Seth Simonson

2 CUMMINS CONFIDENTIAL Goals  Calculate HDD  Furnace on time  Number of on-off cycles  Heat Loss  Correlate Data

3 CUMMINS CONFIDENTIAL HDD & Furnace On Time Date HDD Calculated HDD Actual % Error Furnace on Time # of On-Off Cycles Calculated # of on- off Cycles Seen on Graph Difference Btwn Calc and Graph 1/2231.9330.06.04%2.2429 0 1/2849.3948.02.81%2.0451 0 1/2950.7950.01.56%2.6559 0 2/337.9837.02.58%1.4233 0 2/435.6835.01.91%1.7248 0 2/537.3932.014.4%1.7957 0 2/646.1141.011.1%1.4350 0

4 CUMMINS CONFIDENTIAL HDD Calculated Vs. HDD Published

5 CUMMINS CONFIDENTIAL Furnace On Time Vs. HDD Calculated

6 CUMMINS CONFIDENTIAL Furnace On Time Vs. HDD Published

7 CUMMINS CONFIDENTIAL On – Off Cycles

8 CUMMINS CONFIDENTIAL Calculated On/Off Cycles Vs. Observed

9 CUMMINS CONFIDENTIAL First Floor Areas (ft. 2 ) WallsWindowsDoorsTotal North288.41117.5520.45426.4 South386.53131.2220.25538.0 East360.23018.17378.4 West289.7100

10 CUMMINS CONFIDENTIAL Second Floor Areas (ft. 2 ) WallsWindowsDoorsTotal North499.9475.710575.65 South346.7916.400363.20 East371.7200 West162.5000

11 CUMMINS CONFIDENTIAL Basement Areas (ft. 2 ) WallsWindowsDoorsTotal North142.2900 South263.4200 East291.1300 West157.2500

12 CUMMINS CONFIDENTIAL House Total (ft. 2 ) WallsWindowsDoorsTotal North930.64193.2520.451144.34 South996.74147.6220.251164.61 East1023.08018.171041.24 West805.9000 Walls (cedar)Walls (brick) 1310.571342.80

13 CUMMINS CONFIDENTIAL R - Values Walls (Brick)5.63 Walls (Cedar)5.94 Windows2.00 Doors1.00

14 CUMMINS CONFIDENTIAL Heat Losses Date Avg. T- Out Delta T Wall Heat Loss Window Heat Loss Door Heat Loss Total Heat Loss 1/221.6417.748144.70 3023.401044.2412212.35 1/28-9.2227.44 12598.8 5 4050.781615.3118264.94 1/29-9.6128.22 12956.302082.851661.1416700.30 2/3-2.1521.10 9686.771557.241241.9512485.96 2/4-0.5019.82 9101.741463.191166.9511731.87 2/50.1920.77 9538.451533.391222.9412294.79 2/6-5.1425.61 11760.621890.641507.8415159.10

15 CUMMINS CONFIDENTIAL House Heat Loss Month Heat Loss BTU/hr Heat Loss Therms/mo nth BTU/day Therms/da y BTU/month Therms/mo nth December10321.1076.79247706.402.487678898.4076.79 January12744.7094.82305872.803.069482056.8094.82 February10613.5071.322547242.55713227271.32 March5220.5038.841252921.25388405238.84

16 CUMMINS CONFIDENTIAL Conclusion  HDD calculated vs. HDD published strong correlation and minimal error.  Excel program was modified to yield accurate furnace on/off calculations  Furnace on time vs. HDD & calculated vs. HDD published showed a poor correlation.  House Heat loss calculations yielded reasonable results.


Download ppt "CUMMINS CONFIDENTIAL HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project Team Members: Kaela Hlaulani Prince Bedell William."