1 PEDIATRIC RADIOGRAPHY

2 2 The Role of The Radiographer in Dose Reduction for Paediatrics Cynthia Cowling ACR, B.Sc. M.Ed Director of Education ISRRT Development Leader, Radiation Sciences Central Queensland University, Australia

3 3 Outline Traditional role and techniques Role in CT Dose Reduction Implications for Interventional Dose implications in the move from Analog to digital Some specialized activities

4 The pediatric patient always presents with unique problems for the radiographer Keeping still Use of restraining devices Response to verbal direction Use of shielding Role of the family

5 5 Use immobilization devices judiciously Capture the attention of the child

6 Other Devices Tape (be careful not to hurt skin) Sheets, towels Sandbags Radiolucient sponges Compression bands Stockinettes Ace bandages

7 Radiation Protection ALARA Proper immobilization Short exposure time Limited views Close collimation Lead aprons and half shields

8 Differences children and adults Mental development Chest and abdomen the same circumference in NB Pelvis - mostly cartilage Abdominal organs higher in infants than older children Hard to find ASIS or Iliac Crest in young child, can center 1 inch above umbilicus (bellybutton) Exposure made as baby takes a breath to let out a cry

9 9 Dose reduction in CT Use Radiologists and radiographers must create an essential partnership It is the Radiographer who UNDERSTANDS and OPERATES the equipment All CT sites should cooperate; start reduction and validate results

10 10 Essential features Dose should be age and weight specific Dose should be customized to pathology Number of follow ups should be scrutinized Software features should be used if possible –Image enhancement –Modulation of mAs

11 11 Working with the radiologist, the radiographer… Starts with standard protocol and then reduces to provide acceptable image Screens all requests, re protocol and suitability of request Attempts to narrow down area of interest

12 12 Interventional Procedures Increased because of immediate risk benefit for child (not undergoing surgery) However, not much consideration given to long term stochastic effects

13 13 Collaboration makes a huge difference Example from Hospital for Sick Children, Toronto Canada In Angio CT the TEAM was able to reduce dose from 3 mSev to 0.8 mSev as standard for typical Angio CT exam for child

14 Dose Optimization in CT kVp – decrease kVp, decrease dose, increase image noise, non-linear –Ex. 140 kVp 80 kVp dose by 78% (Siegel M et al, 2004) mAs – decrease mAs, decrease dose, increase noise, linear –Ie. Halve mAs, Halve dose Pitch, length of scan, gantry cycle time

15 Cardiac Angiography CT Protocol Weight-based protocol 1.IV injection of contrast 2.Set parameters: Tube Voltage: 80 kVp Gantry Rotation Time 0.4 s Pitch Variable parameters: Vary mAs According to body weight - <5 kg: 70 mAs [Newborn phantom] kg: 80 mAs [1-, 5-year old phantom] kg: 90 mAs [10-year old phantom] - >50 kg: 100 mAs 4.Scan Coverage Only area of interest

16 Conclusions New protocol/equipment exposes patients to less radiation than previous set-up Doses are less than 1 mSv across all phantoms ~75% decrease from previous protocol Images are of diagnostic quality Project is a good illustration of the utility we have at Sick Kids -> Easily determine radiation risk from various procedures with in-house equipment

17 Moving Forward This study was a general view of the exam Study Clinical assessments to: –Collect data on what scans are used to diagnosis for –Percentage diagnosis yield –Percentage of cases that would have benefitted from lower/higher dose –Can we tighten dose optimization further

18 18 Other Areas attempting dose reduction Scoliosis series

19 EOS 1- Takes two simultaneous digital planar radiographs in the standing position with very low dose : 2D 2D2D2D2D 3D3D3D3D EOS sterEOS 2- Creates a three dimensional bone envelope weight bearing image : 3D

20 Collimated X Ray beam Collimated detector linear detector scanning  No vertical divergence of X rays  No scatter detect  SNR increased  Allows for lower dose ++  No vertical divergence of X rays  No scatter detect  SNR increased  Allows for lower dose ++ Linear scanning of a fan-shaped collimated X ray beam from 5 cm to 180 cm (whole body) Linear scanning of a fan-shaped collimated X ray beam from 5 cm to 180 cm (whole body) Scanning process

21 21 Dose & Image quality –In a linear scanner such as EOS, the detector geometry prevents more than 99.9% of the scattered radiation from entering the detector –EOS allows for a dose reduction up to 10 times compared to CR Clinical impact of dose : M. Doody et. Al., « Breast Cancer Mortality After Diagnostic Radiography », Spine, Vol. 25, No 16, pp  Retrospective study on mortality due to breast cancer (women followed for scoliosis using spine X-Rays) : –5466 women followed between 1912 and Average of 25 radiographs (~0.11 Gy) => Risk of death due to breast cancer is 69% higher than what is encountered in general population. Current practice : - Scattered radiation accounts for more than 80% of the X-ray flux passing through the patient - This noise reduces detectability and therefore a higher dose is required to maintain image quality

22 EOS Dose reduction x9… …With improved or equivalent image quality (97%) High dynamic of image (16 bits, > Levels of Gray). Digital images, DICOM format Single exposure for multiple exams Pixel size 254µm Low dose & High Image Quality Non EOS/Dose x10 Fuji EOS EOS requires less dose (Montreal study on spine) 100% 11% EOS lowers dose by over 89%

23 Slot Scanning Technology –No scatter detected, Noise suppressed  Allows for Lower Dose Charpak Nobel Prize Winning Detector –Detector amplification : Photon gaz cascade,  High gain signal, sensitivity maximized Automatic internal gain adjustment –Dynamic range outperform other digital imaging technology (30,000 gray levels) –Available for any patient! Why Low Dose?

24 24 Analog to Digital, Dose implications Requires changes to radiographer’s knowledge base Radiographers w ork practice must change to ensure high quality images Must be more aware of dose since automation and image acquisition does not provide feedback in image production especially key effects of mAs and kVp Radiographer must work as part of Team to ensure adherence to ALARA QC always critical

25 25 Cont.. Positioning can be more critical, aligning to detectors Manual techniques may be required to produce optimum quality Post processing as a method of enhancing image should be discouraged Exposure creep must be avoided (any more than 4% unacceptable) ADVANTAGE provides statistical evidence of exposure factors and dose

26 26 How the profession can improve dose reduction Increase awareness through membership in initiatives such as Image Gently Provide retraining opportunities Make use of publications such as ICRP Participate in Clinical Audits Actively work collaboratively with radiologists and physicians

27 27 For Example In Ontario, Canada, Radiographers are regulated by the College of Medical Radiation Technologists of Ontario (CMRTO) and Healing Arts Radiation Protection Act (HARP) which controls and identifies who can order and operate x ray equipment

28 28 Recommendations HARP should require that prescribing or requesting a CT be permitted only by individuals who have appropriate clinical knowledge and training in radiation protection All persons operating CT equipment or devices take a radiation safety course documented by a certificate of credentials –200% increase in CTs in Ontario between

29 29 Enhancing Radiation Protection in Computed Tomography for Children Module two Image Gently

30 30 TWO KEY POINTS TEAMWORKTEAMWORK TEAM WORK TRAINING

31 31 Many Thanks and Acknowledgements to Image Gently- Alliance for Radiation Safety in Pediatric Imaging American Society of Radiologic Technologists-ASRT Ellen Charkot, Director Imaging Services Hospital for Sick Children, Toronto Canada Lori Boyd, Director of Policy College of Medical Radiation Technologists of Ontario, Canada (CMRTO) Marie De La Simone, biospace med, Paris France International Society of Radiographers and Radiological Technologists (ISRRT) Maria del Rosario Perez, WHO


Download ppt "PEDIATRIC RADIOGRAPHY. 2 The Role of The Radiographer in Dose Reduction for Paediatrics Cynthia Cowling ACR, B.Sc. M.Ed Director of Education ISRRT Development."