Presentation is loading. Please wait.

Presentation is loading. Please wait.

Introducing The Blokker Why ? Why a Blokker Availability Application Models Available Options Available Comparison Special Features Why? Sewer Flooding.

Similar presentations


Presentation on theme: "Introducing The Blokker Why ? Why a Blokker Availability Application Models Available Options Available Comparison Special Features Why? Sewer Flooding."— Presentation transcript:

1 Introducing The Blokker Why ? Why a Blokker Availability Application Models Available Options Available Comparison Special Features Why? Sewer Flooding Back Water Valve For information on a section click on the box and then advance slides using “Arrow Keys” to navigate. Vent Install AvailabilityReturn Home

2 Preventing Sewer Flooding In Homes and Businesses So, what causes the flooding problems?  Solid materials flowing down sewer lines cause blockages – especially when getting stuck in root balls  Hot fats and oils dumped in sewer lines, solidify and combine with other solid materials in the sewer water to form balls and this creates blockages  Damage to downstream pipelines – for instance pipe damaged by construction equipment blocks pipe flow  Debris swept along with storm water causes blockages in storm water pipelines Blokker Backwater Valve Information Slide 2

3 Main Sewer Line Blockage Residential Example  Obstructions in main sewer line causing sewer water to back up into homes of higher elevation  Blokker Provides protection Blokker Backwater Valve Information Slide 3 Normal Flow Sewer Backup Sewer Lines Obstruction Backwater Flow Blokker Valve

4 Main Sewer Line Blockage Strip Mall / Condo Style Commercial Example  Obstructions in main sewer line causing sewer water to back up into commercial units of higher elevation that have no backwater valve. Blokker Backwater Valve Information Slide 4 Normal Flow Sewer Backup Sewer Lines Obstruction Backwater Flow Blokker Valve

5 How the Blokker Valve Came To Exist SecureLeak Inc. developed, designed, patented, certified and manufacture the Alarmed Blokker Backwater Valve on request of INTAC (previously ING) Insurance Company:  Existing backwater valves were/are not reliable  Leaking under pressure only keeping back solids  Regular Service requirement by Licensed Plumber  No pressure wave protection to prevent valve failure and flooding  Do not comply with Canada Plumbing Codes regarding sewer line venting  Residential sewer flooding causes Billions of Dollars in damage  INTAC required reliable protection and early warning for the home owner  INTAC required a valve with no regular service requirements  INTAC required a product that would minimize their financial liability Blokker Backwater Valve Information Slide 5

6 How the Blokker Valve Came To Exist The Blokker Backwater Valve design parameters were as follows:  Venting of downstream pipelines  Providing sewer line venting as per Canada Plumbing Code requirements  Releasing of pressure waves / surges through vent  Easy installation, straight retrofit, inside or outside building  Alarm warning/monitoring with high sewer line water level  Second alarm warning/monitoring when Blokker Valve closes  No regular inspection / service requirements between backups  Special embedded seal to eliminate leaking at all pressures  No obstructions / transitions in flow path through Blokker Valve  Alarm warning for clogged mechanisms after backup situation Blokker Backwater Valve Information Slide 6

7 How the Blokker Valve Came To Exist The result after many hours of hard work and many Dollars: The Blokker Back Water Valve! CSA Certified, Patents Pending Canada & USA Blokker Backwater Valve Information Slide 7

8 Blokker Backwater Valve Application Main Applications: Retrofit & New Installations 1.4” Sewer lines from single residential units 2.4” Sewer lines from multiple residential units 3.4” Sewer lines from commercial & industrial units 4.4” Sewer lines into main arteries Blokker Backwater Valve Information Slide 8

9 Blokker Backwater Valve Application 4” Sewer lines from single residential units Alarmed Blokker Backwater Valve Presentation Slide 9 Normal Flow Obstruction Backwater Flow Sewer Lines Blokker Valve Ground Level

10 Blokker Backwater Valve Application 4” Sewer lines from multiple residential units: Single Blokker Installation for building Alarmed Blokker Backwater Valve Presentation Slide 10 Normal Flow Obstruction Backwater Flow Sewer Lines Blokker Valve Ground Level Below grade

11 Blokker Backwater Valve Application 4” Sewer lines from multiple residential units: Blokker Installations on every level Blokker Backwater Valve Information Slide 11 Normal Flow Obstruction Backwater Flow Sewer Lines Blokker Valve Ground Level Below grade

12 Blokker Backwater Valve Application 4” Residential Sewer lines into Main Sewer Lines Blokker Backwater Valve Information Slide 12 Normal Flow Obstruction Backwater Flow Sewer Lines Blokker Valve Ground Level

13 Blokker Valve Models Available Alarmed Blokker Unit (without Extension Wire)  High water level and valve closed alarm sensors are factory installed Blokker Backwater Valve Informatation Slide 13

14 Blokker Valve Models Available Alarmed Blokker Unit with Extension Wire  High water level and valve closed alarm sensors are factory installed  5 meter extension wire included. Blokker Backwater Valve Information Slide 14

15 Blokker Valve Options Available Quick Install Vent closes vent during installation  Allows venting during rough in install prior to vent pipe being connected  Quick install vent is removed and venting installed at opportune time during construction Blokker Backwater Valve Information Slide 15

16 Blokker Valve Options Available Extension Cables  Extension cable – 5 meter and 10 meter available  Connects Blokker direct into Home Alarm Control Unit  Connects Blokker to Wireless Radio Signal Units Blokker Backwater Valve Information Slide 16

17 Blokker Valve Options Available Siren Kit Option  Siren Option activates Water Level Siren when sewer pipe runs full  Siren Option de-activates Water Level Siren when water level OK  Siren Option activates Valve Close Siren when Blokker valve closes  Siren Option de-activates Valve Close Siren when valve opens  Blokker wiring connects directly into Siren box  12VDC Adapter powers both sirens.  Optional Battery pack powers sirens during power failures.  Ultra low cost siren solution. Blokker Backwater Valve Information Slide 17

18 Blokker Valve Options Available Wireless Sensors Option Pack  Sending alarm signal from Blokker to Home Alarm Control Unit  Connects directly to Blokker or connects to Extension wire  One unit for sewer line high water alarm  One unit for Blokker valve closing sewer line flow Blokker Backwater Valve Information Slide 18

19 Blokker Valve Options Available GSM Home Alarm System  GSM Home Alarm Control System Alarms and:  Sends SMS or Calls when the water levels are high in Sewer Line  Sends SMS or Calls when the Blokker valve closes Sewer Line flow Blokker Backwater Valve Information Slide 19

20 Blokker Options Available Main Water supply shut off valve. Installs as an addition to the GSM Alarm System Closes when Blokker valve closes. Main water supply valve re-opened with override crank. Blokker Backwater Valve Information Slide 20

21 Blokker Valve Special Feature # 1 Valve closes from the top – not an obstruction in flow path  Flap out of the way during flow conditions up to 90% full Blokker Backwater Valve Information Slide 21

22 Blokker Valve Special Feature # 2 No servicing between backups required  Mechanism protected from debris going down pipeline  No parts of valve in water flow path Blokker Backwater Valve Infomation Slide 22

23 Blokker Valve Special Feature # 3 Servicing only required if “Valve Alarm” remains on after sewer line “Blockage” is cleared.  Rinse valve mechanism through inspection opening Blokker Backwater Valve Information Slide 23

24 Blokker Valve Special Feature # 4 Straight retrofit – no leveling adjustments required  No need for any pipe line level adjustments Blokker Backwater Valve Information Slide 24

25 Blokker Valve Special Feature # 5 Water Level Alarm activates at 80% flow level Blokker Backwater Valve Information Slide 25

26 Blokker Valve Special Feature # 6 Back water valve – Valve Closed = Alarm On Blokker Backwater Valve Information Slide 26

27 Blokker Valve Special Feature # 7 Back water valve open – Valve Close = Alarm Off Blokker Backwater Valve Information Slide 27

28 Blokker Valve Special Feature # 8 Blokker comes ready to connect to Home Alarm Control Unit Blokker Backwater Valve Information Slide 28

29 Blokker Valve Special Feature # 9 Alarm Communications – Wired and/or Wireless Blokker Backwater Valve Information Slide 29

30 Blokker Valve Special Feature # 10 Downstream sewer line vented when valve has closed  Vented pipeline releases pressure waves prevents pipe cracks  Venting is required as venting through main stack disabled by closed flap  Venting of all sewer lines a Canada Plumbing Code requirement Blokker Backwater Valve Information Slide 30

31 Blokker Valve Special Feature # 11 No restriction on “distance to last riser” for installation. Blokker Backwater Valve Information Slide 31

32 Blokker Valve Special Feature # 12 May be installed up to 45° angle  Valve may be buried – no venting required above 30° Blokker Backwater Valve Information Slide 32

33 Blokker Valve Special Feature # 13 Box requirement only 14” by 14” Blokker Backwater Valve Infomation Slide 33

34 Auger enter through inspection eye vent stack Eliminate flood during backup when opening Valve Inspection Cover Blokker Valve Special Feature # 14 Blokker Backwater Valve Information Slide 34

35 Blokker Valve Special Feature # 15 Auger downstream through Blokker empty or flooded Blokker Backwater Valve Information Slide 35

36 Blokker Valve Special Feature # 16 EPDM seal embedded in flap ensures no leaks Blokker Backwater Valve Information Slide 36

37 Blokker Valve Special Feature # 17 Main water supply valve close when Blokker valve closes. Installs as an addition to the GSM Alarm System Main water supply valve re-opened with override crank. Blokker Backwater Valve Information Slide 37

38 Blokker Competitive Comparison Included Feature & Importance BlokkerCompetitor LowMediumHigh 1Straight Retrofit – installation in existing lines YesNo √ 2No service requirement – no servicing costs YesNo √ 3No obstructions in flow path YesNo √ 4No transitions in flow path ensure laminar flow YesNo √ 5Valve flap protected against clogging YesNo √ 6Valve closes when debris floated upstream YesNo √ 7Valve only closes when pipe is 80 % full YesNo √ 8Compliant with sewer line venting codes YesNo √ 9Surge and pressure wave release YesNo √ 10Air Expander for pressure and surge release YesNo √ Blokker Backwater Valve Information Slide 38

39 Blokker Competitive Comparison Included Features & Importance BlokkerCompetitor LowMediumHigh 11High sewer water alarm come standard YesNo √ 12Valve closing alarm come standard YesNo √ 13No fault alarm extension wires available YesNo √ 14Wireless Alarm Radio Sender Units available YesNo √ 15GSM Alarm Control Unit available YesNo √ 16Closing Alarm signals service requirement YesNo √ 17Remote Open/Close functionality available YesNo √ 18Main Water Supply shutoff option available YesNo √ 19Insurance Industry Recommendation YesNo √ 20Rebate on Home Insurance Policy YesNo √ Blokker Backwater Valve Information Slide 39

40 Blokker Competitive Comparison Included Features & Importance BlokkerCompetitor LowMediumHigh 21Special Seal to ensure least leaking possibility YesNo √ 22No CSA Certification installation restrictions YesNo √ 23No distance to last riser restrictions YesNo √ 24Closed valve absorb high pressure surge/wave YesNo √ 25Valve body could withstand 80 psi wave YesNo √ 26Additional work installing venting system NoYes √ 274” cleanout in valve NoYes √ 28Smaller footprint – smaller inspection box YesNo √ 29Purchase cost advantage NoYes √ 30Suitable for Storm Water Drainage Yes √ Blokker Backwater Valve Information Slide 40

41 Blokker Vent Installation Connect to Vent Stack in attic Or install vent directly to outside - preferred Blokker Backwater Valve Information Slide 41

42 Blokker Backwater Valve Avilability The Blokker will be available through many local plumbing wholesalers. Please check our website for a location near you Thank you For more information – Blokker Backwater Valve Information Slide 42


Download ppt "Introducing The Blokker Why ? Why a Blokker Availability Application Models Available Options Available Comparison Special Features Why? Sewer Flooding."

Similar presentations