V16_120815 HIGH PERFORMANCE LED (HPL) SUPERIOR LIGHT OUTPUT LONGER LIFECYCLE LOWER COST CUSTOMIZABLE Presents: Sustainable efficiency POC: CDF – Energy.

Similar presentations


Presentation on theme: "V16_120815 HIGH PERFORMANCE LED (HPL) SUPERIOR LIGHT OUTPUT LONGER LIFECYCLE LOWER COST CUSTOMIZABLE Presents: Sustainable efficiency POC: CDF – Energy."— Presentation transcript:

1 V16_ HIGH PERFORMANCE LED (HPL) SUPERIOR LIGHT OUTPUT LONGER LIFECYCLE LOWER COST CUSTOMIZABLE Presents: Sustainable efficiency POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND)

2 V16_ Lower cost of ownership a)Longer lifetime (15x) b)Less replacement costs c)80% savings on energy 2.Environmentally friendly a)Less heat b)No mercury 3.Pure perfect light a)No UV or IR radiation Global Savings if we all switched to LED technology 1.$67 billion Dollars in electricity costs/year million tons of CO 2 emissions/year 3.More than 1080 million barrels of oil/year 4.Power output of more than 255 power plants Why buy LED lamps? Total cost of the bulbs and the labor to change them is saved! (CND) (CND)

3 V16_ Lower cost of ownership a)Longer lifetime (10x) b)Less replacement costs c)70% savings on energy 2.Environmentally friendly a)Less heat b)No mercury 3.Pure perfect light a)No UV or IR radiation Calgary Savings if we switched Street Lights to our LED technology 91 Watt vs. 250 Watt High Pressure Sodium Lights *EEMCSC Page 5 example 1.$26 Million Dollars in electricity & costs/year 2.25 thousand tons of CO 2 emissions/year 3.50,000 barrels of oil/year LED Street Lamps? Total cost of the bulbs and the labor to change them is saved! (CND) (CND)

4 V16_ Retail Supermarkets Cooler/Freezer Cases Offices Airports Factories Gas Stations Shopping Malls Schools Warehouse Parking Garages Restaurants APPLICATIONS TUBE LIGHTING HIGHBAY LIGHTING Retail Warehouse High Bays Parking Garages Gas Stations Industrial Tunnels Soffits Flood Lights Sports Courts Supermarkets Offices Airports Factories Streets Airports Parking Lots Gas Stations Pathways Shopping Centers Parks Warehouse Schools Sports Courts STREET LIGHTING PAR LIGHTING Offices Airports Retail Stores Gas Stations Shopping Malls Museums Galleries Hospitals Homes Restaurants (CND) (CND)

5 V16_ * Watt HPS Street Light 288 Watts x 10 hrs. = 2880 WH per day 2880 WH x 365 days = 1,051,200 WH or 1,051.2 KWH per year Cost/yr: 1,051.2 KWH x $0.10/KWH = $ per 288 watt HPS street light Electrical energy cost of one 288 watt HPS street light over 50,000 hours (13.7 years) = $ Watt HPL TECHNOLOGIES Street Light 91 Watts x 10 hrs. = 910 WH per day 910 WH x 365 days = 332,150 WH or KWH per year Cost/yr: KWH x $0.10/KWH = $33.22 per 91 watt LED street light Electrical energy cost of one 91 watt LED street light over 50,000 hours (13.7 years) = $ Energy Cost Savings over the life span of one HPL Technologies Street Light vs. conventional HPS street light = $ (68% energy savings) (CND) (CND) 250 watt High Pressure Sodium (HPS) streetlight lamp consists of a 250 watt bulb plus the ballast which consumes greater than 38 watts of energy = 238 watts energy consumption. Average maintenance and replacement costs of one street light: The Street light lamp bulb is replaced every three years (3.0 years) = $200 (labor) +$50 (bulb) + $5 (waste mgt.) = $255 every 3 years or $85 / yr. The ballast is replaced every 5 years at a cost of $350 (ballast + labor + waste mgt.) or $70/yr. The fixture/aluminum head is replaced every 18 years at a cost of $425 or $23.61 per year. Therefore, the average maintenance and replacement cost per year is $ Over the lifespan equivalent of a LED street light of 50,000 (13.7 years), the cost savings of maintenance / replacement of one current HPS street light is: 13.7 x $178.61/yr. = $ Maintenance & Energy Cost Savings by converting to One HPL Technologies Street Light: Maintenance Cost Savings ($2,446.96) and Energy Cost Savings ($985.03): $3, or cost savings per year per HPL Technologies Street Light. Return on Investment (R.O.I.): 3.6 years $739 (Additional cost of LED street light fixture vs. conventional) + Installation $200 = $939 expense divided by $ / yr. savings = 3.6 years A city/town with an average of 100,000 street lights will save $ Million over the lifespan of the LED Street Lights. Applicable Savings from Energy Rebates and CO2 tax credits approx $10.00 per year per post to further reduce the ROI. Note: energy and maintenance costs continue to escalate. Estimated Energy and Maintenance Cost Savings Calculations HPL TECHNOLOGIES Street Light vs. Conventional Street Light

6 V16_ * Watt Fluorescent Light 108 Watts x 10 hrs. = 1080 WH per day 1080 WH x 365 days = 394,200 WH or KWH per year Cost/yr: KWH x $0.10/KWH = $39.42 per 108 watt fluorescent light Electrical energy cost of one 108 watt fluorescent light over 50,000 hours (13.7 years) = $ Note: Fluorescent tubes would have to be replaced approx. 7 times during the life span of one LED Linear Luminaire 36 Watt HPL Linear Luminaire 36 Watts x 10 hrs. = 360 WH per day 360 WH x 365 days = 131,400 WH or KWH per year Cost/yr: KWH x $0.10/KWH = $13.14 per 36 watt LED Linear Energy Cost Savings/yr (66.6%): $26.28 (LED vs. fluorescent) Electrical energy cost of one 36 watt LED Linear over 50,000 hours (13.7 years) = $ Energy Cost Savings over the life span of one HPL Linear Light vs. conventional Fluorescent Light = $ (68% energy savings) (CND) (CND) * 72 Watt Fluorescent light consists of a 2 x 32 watt mercury tubes, and a ballast which consumes 36 watts of energy = 108 watts. Average maintenance and replacement costs of fluorescent tubes and ballast: Maintenance cost to replace florescent tubes: $ Fluorescent tubes have to be replaced every two years (2.0 years) and Ballast every 5 years; therefore, maintenance $12.50 per year + cost of tubes $2.5 + cost of ballast and labor replacement $25 + $5.0(waste mgt.) = $45.00 maintenance and replacement cost per year. Over the lifespan equivalent of a LED Linear Luminaire of 13.7 years the cost of maintenance / replacement of one fluorescent is: 13.7 x $45/yr. = $ ROI: Savings per year (Energy, air conditioning and maintenance): $ $ $45.00 = $81.14 / yr. savings $150 (LED Linear Selling Price) divided by $81.14 / yr. savings = 1.8 years R.O.I. Note: Energy Saving Rebates have to be added to the ROI plus carbon credits plus escalating cost of energy. $3,000,000 in carbon tax credits would be generated annually for every 1 million fluorescent lighting fixtures replaced with Remco’s linear LED luminaires, approximately $12 million in carbon tax credits generated annually to replace 4 million fluorescent lighting fixtures. Note: energy and maintenance costs continue to escalate with conventional lighting. Estimated Energy and Maintenance Cost Savings Calculations HPL 36 Watt Linear LED Luminaires vs. 72 Watt Fluorescent Tubes

7 V16_ FEATURES & SPECIFICATIONS Lighting Angle: Color Rendering: Power Factor: Lamp Life: Replaces: Warranty: 120° ,000 Hours Fluorescent Tubes 5 Years Retail Warehouse Schools Parking Garages Gas Stations Industrial Tunnels Soffits Hospitals Sports Courts Supermarkets Offices Airports Factories APPLICATIONS LED T8EX 4ft Tube External Driver Series Catalog Number NotesQuantity Ordering Information Lead times will vary depending on options selected. Consult with your sales representative. Example: T8EXR 4 MT NW 192 CL BI T8EX T8EXR Voltage Color Correlated Temperature Series MT 2 2 Tubes 3 3 Tubes 4 4Tubes 6 6 Tubes MT AC V WW K NW K DW K CW K CL Clear FS Frosted # of TubesWattageLumens End Type (2) BI Bi Pin G13 HO High Output Notes: 1.When ordering HO ends, consult your representative for proper fit. System Lens Type POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND)

8 V16_ LED T8EX 4ft Tube External Driver Series HPL Technologies uses an external driver for their tubes systems. This provides a system designed for maximum life and consistent performance. With an external driver you separate the heat produced by both the LED chips and driver and greatly reduce the accelerated wear on both components. Each tube is driven on its own channel and is not affected by the other tubes in the system. HPL Technologies uses current production top of the line LED Chips. Not all chips are the same and this is evident in CRI, lumen output and depreciation. Our chip boards are designed and configured to dissipate maximum heat while providing a seamless distribution of light. We also under drive our chips from the recommended mA current provided by the chip manufacturer to control the amount of heat produced by the chips. With HPL Technologies engineering and design you can be assured you are using the most advanced LED tube system on the market. And with a proven track record and constant improvement in our products, HPL Technologies will be your only source for LED products. Driver Technology LED Chip Technology System Advantages (CND) (CND)

9 V16_ FEATURES & SPECIFICATIONS Lighting Angle: Color Rendering: Power Factor: Lamp Life: Replaces: Warranty: 120° ,000 Hours Fluorescent Tubes 5 Years Retail Warehouse Schools Parking Garages Gas Stations Industrial Tunnels Soffits Hospitals Sports Courts Supermarkets Offices Airports Factories APPLICATIONS LED T8EX Refrigeration Series Catalog Number NotesQuantity Ordering Information Lead times will vary depending on options selected. Consult with your sales representative. Example: T8EXR 4 MT NW CL BI T8EXR Voltage Color Correlated Temperature Series (1) MT 4 4 Feet 5 5 Feet 6 6 Feet MT AC V WW K NW K DW K CW K CL Clear FS Frosted Tube Length WattageLumens End Type (2) BI Bi Pin G13 HO High Output Notes: 1.This series assumes there is only one tube per ballast on the existing installation. If more than one tube per driver is required please consult with your representative. 2.When ordering HO ends, consult your representative for proper fit. Tube Length Lens Type POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND)

10 V16_ FEATURES & SPECIFICATIONS Lighting Angle: Color Rendering: Power Factor: Lamp Life: Replaces: Warranty: 120° ,000 Hours Fluorescent Tubes 5 Years Retail Warehouse Schools Parking Garages Gas Stations Industrial Tunnels Soffits Hospitals Sports Courts Supermarkets Offices Airports Factories APPLICATIONS LED T8EX 4ft Wraparound Series Catalog Number NotesQuantity Ordering Information Lead times will vary depending on options selected. Consult with your sales representative. Example: T8EXW 3 MT NW CL BI T8EXW VoltageColor Correlated Temperature Series MT 2 2 Tubes 3 3 Tubes MT AC V WW K NW K DW K CW K CL Clear FS Frosted # of TubesWattageLumens End Type BI BI Bi Pin G13 Notes: System Lens Type POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND)

11 V16_ FEATURES & SPECIFICATIONS Lighting Angle: Color Rendering: Power Factor: Lamp Life: Replaces: Warranty: 120° ,000 Hours Fluorescent Tubes 5 Years Retail Warehouse Schools Parking Garages Gas Stations Industrial Tunnels Soffits Hospitals Sports Courts Supermarkets Offices Airports Factories APPLICATIONS LED T8EX 4ft High Bay Series Catalog Number NotesQuantity Ordering Information Lead times will vary depending on options selected. Consult with your sales representative. Example: T8EXH 6 MT NW CL BI T8EXH Voltage Color Correlated Temperature Series MT 4 4 Tubes 6 6 Tubes MT AC V WW K NW K DW K CW K CL Clear FS Frosted # of TubesWattageLumens End Type BI BI Bi Pin G13 Notes: System Lens Type POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND)

12 V16_ FEATURES & SPECIFICATIONS Lighting Angle: Color Rendering: Power Factor: Lamp Life: Replaces: Warranty: 120° ,000 Hours Fluorescent Tubes 5 Years Retail Warehouse Schools Parking Garages Gas Stations Industrial Tunnels Soffits Hospitals Sports Courts Supermarkets Offices Airports Factories APPLICATIONS LED T8EX Troffer Series Catalog Number NotesQuantity Ordering Information Lead times will vary depending on options selected. Consult with your sales representative. Example: T8EXT 24T MT NW CL BI T8EXT Fixture Type Voltage Color Correlated Temperature Series MT 23 2x2 3 Lamp 24 2x4 3 Lamp MT AC V WW K NW K DW K CW K CL Clear FS Frosted FixtureWattageLumens 22T T End Type BI BI Bi Pin G13 Notes: Lens Type POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND)

13 V16_ FEATURES & SPECIFICATIONS Lighting Angle: Color Rendering: Power Factor: Lamp Life: Replaces: Warranty: 120° ,000 Hours Fluorescent Tubes 5 Years Retail Warehouse Schools Parking Garages Gas Stations Industrial Tunnels Soffits Hospitals Sports Courts Supermarkets Offices Airports Factories APPLICATIONS LED T8EX Parabolic Series Catalog Number NotesQuantity Ordering Information Lead times will vary depending on options selected. Consult with your sales representative. Example: T8EXP 24T MT NW CL BI T8EXP Fixture Type Voltage Color Correlated Temperature Series MT 22 2x2 2 Lamp 24 2x4 3 Lamp MT AC V WW K NW K DW K CW K CL Clear FS Frosted FixtureWattageLumens 22P P End Type BI BI Bi Pin G13 Notes: Lens Type POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND)

14 V16_ FEATURES & SPECIFICATIONS Color Rendering: Power Factor: Lamp Life: IP Rating: Housing: ,000 Hours 67 Aluminum Retail Warehouse High Bays Parking Garages Gas Stations Industrial Tunnels Soffits Flood Lights Sports Courts Supermarkets Offices Airports Factories APPLICATIONS LED High Bay/Canopy/Tunnel/Garage Series Catalog Number NotesQuantity Ordering Information Lead times will vary depending on options selected. Consult with your sales representative. Example: CTG 70 MT DW 5 SM Yes BL HCTG Wattage VoltageColor Correlated Temperature Light Angle (1) Mounting Series MT AC V 480 AC 480 WW K NW K DW K CW K See Optics Chart For Options SM Surface PE Pendant HO Hook WattageChip CountLumens Dimmable (2) Color No Yes Pre-programmed GR Grey BL Black BZ Bronze CU Custom (CND) (CND)

15 V16_ This versatile LED fixture was designed for direct replacement of HID lighting in any industrial or commercial application. This fixture is available with multiple optic options and can be customized to provide equal illumination for any application. HPL Technologies Highbay series is the only fixture on the market specifically designed for high mast lighting. It is engineered with open lighting modules to reduce the effect of air currents that are present at extreme heights on its EPA. Its also has a mounting that balances its weight inward thereby reducing the leverage exerted on the mounting pole. Along with its high lumen output and Remco and Philips Advance drivers, the HPL Highbay will replace any HID high mast lighting. Whether you require 24 hour operation or full DALI controls for maximum energy savings, HPL Technologies can design a lighting system to fit your specific needs. Total cost of the bulbs and the labor to change them is saved! LED High Bay/Canopy/Tunnel/Garage Series mounting options OD PW CH TU FL RE (CND) (CND)

16 V16_ Color Correlated Temperature WW K NW K DW K CW K Light Angle (1) See Optics Chart For Options FEATURES & SPECIFICATIONS Color Rendering: Power Factor: Lamp Life: IP Rating: Housing: Tilt Angle: Operating Temp: Surge Protection: ,000 Hours 67 Aluminum -30° to 90° -40°F to 149°F 4KV Streets Parking Lots Pathways Parks Airports Gas Stations Shopping Centers Warehouse APPLICATIONS LED Street Series Catalog Number NotesQuantity Ordering Information Lead times will vary depending on options selected. Consult with your sales representative. Example: ST 70 MT DW 3 Yes OD Yes GR ST SeriesVoltage MT MT AC V 480 AC 480V Photocell Yes No WattageChip CountLumensWeight/lbDimensions/in x x x x x x x x x x x x x x x x 4.01 Mounting (2) OD 2 3/8 Pole WA Wall Dimmable (3) No Yes Pre-programmed Notes: 1.Consult your representative for information about different angles. 2.Lights will fit onto a pole with an outer diameter up to 2 3/8 inch. 3.Consult your sales representative for the pre-programmed option. Color GR Grey BL Black BZ Bronze CU Custom Wattage (CND) (CND)

17 V16_ LED Street Series WattageBUG RatingL70 25˚ CDimensions/in 61B1–U1–G1> 105, x x B2-U2-G2> 105, x x Pending> 105, x x Pending> 105, x x Pending> 105, x x Pending> 105, x x Pending x x Pending x x 4.01 Additional Specifications and Performance Information Testing Certifications: LM70 and LM80 information is provided by Cree LM79 testing files are provided by a third-party POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND)

18 V16_ POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND) Type 1 Symmetric Medium Type 1 Symmetric Short Type 1 Symmetric Large Type 2 Asymmetric Medium Type 5 Symmetric Medium Type 2 Asymmetric Small Type 3 Asymmetric Large Type 4 Asymmetric Short High Bay & Street Optic Codes Place these codes on order form. 345

19 V16_ POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND) Street Series Engineering Patented Modular Design Patented and Precise Optics

20 V16_ POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND) Street Series Engineering -30 to 90 Degree Mounting Rotation Tool-Free Locking Design

21 V16_ Chip Type (1) CR Cree XPE DE Double End FEATURES & SPECIFICATIONS Color Rendering: Power Factor: Lamp Life: Replaces: ,000 Hours Par W Par W Par W Offices Retail Stores Schools Shopping Malls Galleries Homes Supermarkets Hospitals Airports Museums Restaurants Gas Stations APPLICATIONS LED Par Series Catalog Number NotesQuantity Ordering Information Lead times will vary depending on options selected. Consult with your sales representative. Example: Par CR NW E No PAR Size/LED Count VoltageColor Correlated Temperature Base Series 2012 Par 20/12 LED 204 Par 20/4 LED 305 Par 30/5 LED 307 Par 30/7 LED 389 Par 38/9 LED 3812 Par 38/12 LED 120 AC 120V 277 AC 277V WW K NW K DW K CW K E26 E27 SizeWattageLumens Dimmable (3) Light Angle (2) Par degree degree degree Par degree degree degree Par degree degree Yes No Notes: 1.Custom chip types and bin sorts are available for larger orders. 2.Custom light angle available for larger orders. 3.If ordering lamps that will never be dimmed, order non-dimmable (CND) (CND)

22 V16_ Location: DFAS, Limestone, Maine Product: 1200 LED T8 Tubes Location: Luke AFB, Arizona Product: High Mast LED Flood Lights Location: Utah Transportation Authority Product: LED Parking Lot Lights for Multiple Locations Location: Steed Military Training Center, Reno, Nevada Product: 1100 LED T8 Tubes, 400 A19 LED Bulbs Location: Utah Valley University Product: LED Parking Lot Lights Location: University of Utah Product: 400 Par Lamps for the Museum of Fine Arts More project references are available if needed. Actual contact information is available upon request. COMPLETED LED PROJECTS TUBE CANOPY STREET PAR HPL Technologies is a Food Safety and Plant Resources company. POC: CDF – Energy Solutions and Developer Past Performances Available Preferences: Tribal 8(a), SDVOSDB, WOSDB, WOEDSB, NAOSDB, VA Verified and other certifications - CCR & ORCA (CND) (CND)