Presentation is loading. Please wait.

Presentation is loading. Please wait.

FERMAX TECHNICAL SEMINAR. The Riser Panel Terminals Riser Basics Amplifier Configuration Models The Technical Book Why DUOX? System Summary How to make.

Similar presentations


Presentation on theme: "FERMAX TECHNICAL SEMINAR. The Riser Panel Terminals Riser Basics Amplifier Configuration Models The Technical Book Why DUOX? System Summary How to make."— Presentation transcript:

1 FERMAX TECHNICAL SEMINAR

2 The Riser Panel Terminals Riser Basics Amplifier Configuration Models The Technical Book Why DUOX? System Summary How to make a material list Audio/Video 1 to n panels 1 to n terminals Introduction At a Glance How to Sell Technical Aspects Technical characteristics DUOX Technical Department Course Layout Catalogue Programmer tool MappingProgramming Auto Switch-ON Catalogue Technical Manuals

3 The target of the DUOX is to implement a system based on two non polarized wires with digital audio and video similar in cost to VDS. Furthermore, DUOX will offer the functionalities of the already existing systems (such as 4+N, VDS, Bus2, MDS). DUOX is the first fully digital system in the market that requires two non-polarized wires for: power, audio, video & data transmission With this new technology, the best characteristics of the previous systems converge: MDS: High performance and great capacity. VDS: Competitive price. Wiring flexibility. BUS2: 2 non polarized wires. Resulting in DUOX, a GLOBAL SYSTEM FOR ALL THE MARKETS. Its main objective is to substitute all the previous systems in a 3 years period. DUOX Technical Department Introduction

4 Features Installation Complexity 4+N Direct & City Call becomes Digital “Many Apartments” “Many Panels” (up to 7) “Thousands of apartments” “Thousands of panels” Digital MDS Duox: System of systems Historically, manufacturers have sold installation simplicity. MDS put apart the 4+N call wires, adding advanced features such as access control, electronic directory and automation. Installation complexity was kept similar to its antecesor. VDS has kept a capacity big enough to satisfy the most common installations, achieving at the same time a dramatic wiring reduction. BUS2 reduced installation to its minimum expression, offering added-value functions such as bus-command relay activation, diagnose tooling and installation simplicity. DUOX keeps the simplicity of Bus2 (2 non- polarized wires), introducing the advantages of the digital audio and video (Improvement of quality, less noise and feedback,…), and extending the capabilities of the system from villas kits to big condominiums (like MDS). VDS “Few Wires” “Many apartments” “Minimum Wiring” “Digital audio” “Thousands of apartments” Microprocessor Terminals Frequency Multiplexing DUOX BUS2 Digital Audio “Minimum Wiring” “Many apartments” DUOX Technical Department Why DUOX?

5 - Up to 10 panels and 10 guard units at the General entrance and at each block. - Up to 10 panels at each Sub-block. Features From villas kit to big condominiums DUOX Technical Department System Summary (1) - Up to 3 terminals in the same apartment (Add dedicated PSU+Filter for this apartment). - Same programming as in VDS and Bus 2. 3 LEVELS: - General entrance. - Block entrances. Up to 99 blocks. - Sub-Block entrances. Up to 99 Sub-Blocks per block. ADDRESSING - Up to addresses (apartments). - Terminals address format: 6 digits, from to

6 Basic VIDEO system features without additional devices like: Risers distributor / Regenerator: Max. 120 meters between 2 communication points (With additional PSUs+Filter). Max. 3 risers at the bus. Max. 4 apartment splits at each riser point. DUOX Technical Department System Summary (2) VIDEO Minimum Voltage: Minimum voltage 15 Vdc at any point in the installation. Minimum Data voltage 1 Vpp, measured via DUOX tester Ref Max. 3 risers at bus Riser Risers Riser Max. 4 apartment splits at each riser point. Max.distance between riser and telephone: 20 meters.

7 1 RISER: Power for VIDEO BUILDING Installations DUOX Technical Department System Summary (3) (i) For 12 Vdc door lock max. 250 mA supplied from amplifier. (ii) Each additional PSU+filter allow to expand the system in distance and terminals according to the table. (iii) Longer distances can be reached via regenerators. In case of existing spare wires in same slope, recommended to reinforce the 2 bus wires instead of remaining as loose wires (Possible antenna effect). Initially 1x(PSU 4812+Filter) = Panel+12Monitors Each 1x(PSU 4812+Filter) = 20Monitors

8 2 RISERS: Power for VIDEO BUILDING Installations DUOX Technical Department System Summary (4) (i) For 12 Vdc door lock max. 250 mA supplied from amplifier. (ii) Each additional PSU+filter allow to expand the system in distance and terminals according to the table. (iii) Longer distances can be reached via regenerators. In case of existing spare wires in same slope, recommended to reinforce the 2 bus wires instead of remaining as loose wires (Possible antenna effect). Intitially 1x(PSU 4812+Filter) = Panel+12Monitors Each 1x(PSU 4812+Filter) = 20Monitors

9 3 RISERS: Power for VIDEO BUILDING Installations DUOX Technical Department System Summary (5) (i) For 12 Vdc door lock max. 250 mA supplied from amplifier. (ii) Each additional PSU+filter allow to expand the system in distance and terminals according to the table. (iii) Longer distances can be reached via regenerators. In case of existing spare wires in same slope, recommended to reinforce the 2 bus wires instead of remaining as loose wires (Possible antenna effect). Initially 1x(PSU 4812+Filter) = Panel+12Monitors Each 1x(PSU 4812+Filter) = 20Monitors

10 Power for VIDEO 1-2 WAYS KIT Installations DUOX Technical Department System Summary (6) (i) For 12 Vdc door lock max. 250 mA supplied from amplifier.

11 CASCADE Distribution: 30 Monitors DUOX Technical Department System Summary (7) STAR Distribution : 10 Monitors at 5 floors (Replace of 1+N Installations) OFF: Internal termination PSU 20 Meters Monitor 1 Monitor 30 Monitor 2 PSU 90 Meters =30 Floors x3m OFF: Internal termination PSU 10 Meters 15 Meters =5 Floors x3m Floor 1 Floor 2 Floor 3 Floor 4 Floor 5 Floor 1 Floor 2 Floor 30

12 WIRES SUPPORTED PARALLEL (RED & BLACK). min 0,14mm 2. UTP. UTP CAT-5. REFURBISHMENT: o 5 WIRES CABLE o DOOR BELL 2 WIRES o OLD 4+N CABLE Remarks: With each type of cable, distance will depend on the load of terminals, topology, number of PSUs, and active terminals at the same time. It is recommended to use a parallel cable with cross section thicker than 0,25mm 2, especially due to the drop voltage in the long distances. It is possible to use other type of cables as alternative, such as Cat-5 or twisted pair, taking into consideration that the maximum distance will be reduced. DUOX Technical Department System Summary (8) Parallel Cable Ref.5925 (2x1mm2) Twisted Pair Refurbishment 9/10ème (3 rolled pairs) UTP (CAT-5)

13 Block 00 PSU 3243 PSU 3243 PSU 3243 PSU 3243 General Entrance (GE) GE, Panel 0 GE, Panel 2GE, Panel 3 DUOX Technical Department VIDEO General Entrance / Block / Sub-Block Block 01 Block 99 Sub-Block 04 GE, Panel 1 Sub-Block 00 System Summary (9) PSU 3243 PSU 3243 PSU 3243

14 DUOX “Full digital system on 2 non polarised wires” BUS driven Relay Duox: The evolution. BUS2 “2 non polarised wires” Panels Switcher Signal Distributor BUS driven Relay DUOX Technical Department 3 + Cx 3 + Coax VDS “3 + Coax” 3 S Connection Video Distributor Panels Switcher Relay with additional wiring System Summary (10) Line termination at last split to avoid reflections 2 In VIDEO a Line termination at the first split.

15 Systems comparison DUOX Technical Department System Summary (11) VDSBUS 2DUOX Addresses Panels22 10 at General Entrance / 10 per Block and Sub-block Guard units1None, only via MDS10 at General Entrance / 10 per Block Distance200 m 120 m video per branch without regenerator (Expandable) PrivacyYes Power18 Vdc for all signals24 Vdc for all signals + Filter Ref Vdc Ref.4812 for all signals + Filter Ref.3243 Type of audio/videoAnalog/Analog Digital/Digital Inmunity against noises and feedbackLowMediumHigh Wiring 3 wires + Coaxial Wiring flexibility (Several type of cables) 2 non polarized wires Restricted cables applicable (Parallel, twisted pair) to keep impedance for proper signal transmission 2 non polarized wires Wiring flexibility (Several type of cables) PriceCompetitiveHighCompetitive Transmission media Signals delivered in different physical media ("L", "+", "-", "M", "V") All signals : Supply, commands, audio and video delivered in the same physical media, 2 wires All signals : Supply and data (Commands, audio, video) delivered in the same physical media, 2 wires End of line termination 75 Ohm resistor between "M", "V" for video impedance. 10 KOhm resistor between "L", "+" for pull-up. Line termination to avoid reflections, set via jumpers located at riser devices. Line termination Ref.3255 to avoid reflections, set via device located at last riser split. Relay, Additional featuresRef.2013 via additional wiring Bus2 relay without additional wiring managed via commands ("F1", "F2", opening,…) DUOX relay without additional wiring managed via commands ("F1", "F2", opening,…) Troubleshooting and programming toolNoYes

16 Main Duox characteristics The DUOX electronics allows that power supply, data, audio and video are delivered in the same bus with 2 non polarized wires. Supplied with 18 Vdc Ref.4812 v.2.0 for all signals via a coupling module Ref.3243 (Minimum functional voltage 15 Vdc at terminal and amplifier). Full Digital system (audio, video and data). Privacy in communications. DUOX Technical Department System Summary (12)

17 DUOX Advantages: Additionally to the advantages of the digital audio and video, DUOX system offers other improvements in comparison with the existing systems: COMPARED TO BUS2: Since the operation frequency has been reduced further distances under the same circumstances are achieved. Intermedia devices that were required in Bus2 to boost or distribute the signal are no longer necessary in DUOX. Only “Line termination” will be used to avoid reflections and to adapt line impedance. COMPARED TO VDS: The parasitic capacitance of the cables that was a limiting factor in VDS where pull-up resistors were necessary is not an issue anymore. COMPARED TO ALL: –It collects the best features from other systems: High performance, wiring flexibility, competitive price and installation simplicity. DUOX Technical Department System Summary (13) End of line termination used in DUOX: To avoid reflections. End of Line Termination In VIDEO a Line termination at the first and last split.

18 LINE TERMINATION Ref.3255: To be installed at bifurcations to adapt the transmission line. Basic modes of Ref.3255 to be used: 1.“A” to absorb reflections: At the last bifurcation in installations with several terminals and with significant distance between main riser and the distributed terminals. See Kit case c). 2.“C” to adapt the line: At the first bifurcation (panel’s side), and at the last bifurcation in case of cascade distribution. See Kit case b). 3.Note that in case of 1 Way kits, Ref.3255 is not necessary at the panel’s side, we will use an internal termination at the amplifier (Jumper in ON position). See Kit case a). DUOX Technical Department System Summary (14) A KIT Cases Building Cases

19 TOPOLOGY – FIRST STAGE 1 x RISER: 100 TERMINALS. DUOX Technical Department The riser (1) OFF: Internal termination

20 TOPOLOGY – FIRST STAGE 2 X RISERS: 100 TERMINALS (50 TERMINALS PER RISER). DUOX Technical Department The riser (2) OFF: Internal termination OFF: Internal termination

21 TOPOLOGY – FIRST STAGE 3 x RISERS: 60 TERMINALS (20 TERMINALS PER RISER). DUOX Technical Department The riser (3) OFF: Internal termination OFF: Internal termination

22 Basics 18 VDC PSU Power supply Adaptor VDC PSU Power supply adaptor Up to 120 m 10 panels and 10 guard units per block 18 VDC PSU Power supply Adaptor Kit Simple Building Multiple accesses 18 VDC PSU 3243 DUOX Technical Department The riser (4) End of Line Termination ON: Internal termination OFF: Internal termination OFF: Internal termination

23 Basics: VIDEO Kits 18 VDC PSU Power supply Adaptor If there is only one monitor, just a single line termination is required (Ampli Internal termination ON). -If more than one monitor are installed, a second line termination in the riser node may be required. Kit with one telephone DUOX Technical Department The riser (5) Power supply Adaptor Kit with addtional telephones Line Termination 18 VDC PSU Cascade Power supply Adaptor ON: Internal termination OFF: Internal termination OFF: Internal termination 18 VDC PSU

24 Basics VIDEO with general entrance 18 VDC General entrance to villas General entrance and panels at each floor 18 VDC VDC DUOX Technical Department The riser (6) Up to 120 m 10 panels and 10 guard units per sub-block End of Line Termination 18 VDC VDC VDC VDC VDC VDC VDC VDC VDC 3243

25 Power Supply unit + Power Filter DUOX Technical Department The riser (7) 220Vac 18Vdc The output capacitor behaves like a shortcircuit for DUOX signals DUOX Riser Couples DC current (power) to the DUOX BUS DUOX Power Supply Filter Ref.3243 Prevents DUOX signals to traverse NET Power is coupled by mean of inductances. It is used the same filter module Ref.3243 as in Bus2. Not any power supply is valid, as the used power supply has not to introduce common noise in the DUOX bus. Fermax references: Use Ref.4812, 18 Vdc, 1,5 A. Version 2.0. The DUOX signal will not leave the bus due to the high impedance presented by the filter. 4812

26 DUOX Programmer Ref.3254 It will be used to make easier the configuration and to identify problems in an installation. The format of the tool will be like the Loft access control readers (Simple display and keypad). Same programmer tool for all DUOX devices (current and futures). The information is managed by the programmed device. Operation modes: 1._ Configurator Mode It allows programming of: Telephones (Address, melody, door matic). Tester connected to telephone plug. Panel amplifier (Number, mode, opening times, guard units modes). Tester connected to Amplifier “CN1”. See pictures). 2._ Analyzer Mode (Tester connectes to the 2 wires of bus) It allows different functions: Devices detection (Terminals, amplifiers, guard units). Analysis of frames. Call to apartments. “Channels in use” detection. Meassuring of signals (Voltage,…). Status of telephone (Existance, hook, occupied, do no disturt, doormatic,…). DUOX Technical Department The riser (8) Skyline Ampli 6 pins City Ampli 5 pins

27 Models KIT 1-2 WAY: Internal pushbuttons. “Inverse” programming to allow no limitation of panels according to telephone address (Useful for villas). DIRECT : addresses. One Access code for door opening. Keypad used for system configuration. PUSHBUTTONS: 99 addresses. Continuous profile with call extension pack. Skyline with pushbuttons modules. One to one module adaptable. DIGITAL : Text and graphical display. DUOX programming software. Access codes for door opening. DUOX Technical Department Panel (1) Panels with combination of keypad + pushbuttons (Dentist,…).

28 Marine panel with buttons DUOX Technical Department Panel (2) As Marine panels have no integrated buttons, it is necessary to install the call extension packs (Ref.2008 or Ref.2441) for any MARINE DUOX buttons panel, even for 1-2 way panels (Not like VDS 1-3 buttons).

29 DUOX Amplifier VIDEO: Connections DUOX Technical Department Panel (3) SymbolDescription P1Connection of right pushbutton to call extension pack B,BDUOX Bus : Audio-video, data and supply C, NO, NCDoor opener relay contact. +12Output 12Vdc to supply access control or DC door opener. Max.500mA BSExit button -Negative of amplifier. (For “Bs”, “S”,…) SInput for door sensor. Connected to “-” means door closed. +18,GNDInput of supply 18Vdc. For small installations without filter. P2Connection of left pushbutton to call extension pack “One To One” connection for information module Connection of call extension pack or keypad, or pushbutton modules Tamper connection against manipulation of panel: A sensor will control if someone tries to remove the panel screws sending an event to the guard unit “PGR” Button for Master and mapping configuration Voice synthesizer: 29 different languages Audio volume potentiometers: Uplinks Downlinks Voice synthesizer Status led: Off: Night mode for guard unit 2 blinks per second: Day or mixed mode for guard unit 1 blink per second: Inverse and Sequential programming “JP2” ON Internal line termination as “C” mode.

30 DUOX Amplifier: Supplied via filter module through “B”, “B” DUOX Technical Department Panel (4) 220 Vac 18 Vdc 4812 ON: Internal termination

31 DUOX Technical Department 220 Vac 18 Vdc 4812 Amplifier 1 Amplifier PSU 3243 Filter DUOX: 2 x amplifier / 1 x PSU / 1 x Filter Panel (5) ON: Internal termination

32 DUOX Technical Department DUOX: 2 x amplifier / 2 x PSU / 2 x Filter 220 Vac 18 Vdc 4812 Amplifier 1 Amplifier PSU 3243 Filter 220 Vac 18 Vdc PSU 3243 Filter Panel (6) OFF: Internal termination OFF: Internal termination

33 Panel configuration (1) DUOX Technical Department Panel (7) MODE Number of Block or Sub-block Number of PanelPanel can call to RANGE of telephones: GENERA ENTRANCE (GE)NoneFrom 0 to to BLOCK (B)From 00 to 99From 0 to to SUB-BLOCK (S)From 00 to 99From 0 to 901 to 99 At each panel we have to configure: 1._ The mode: 1.1_ As General Entrance. 1.2_ As Block / If this is the case, additionally the number of the Block. 1.3_ As Sublock / If this is the case, additionally the number of the Sub- Block. 2._ The number of the panel.

34 Panel configuration (2) DUOX Technical Department Panel (8) Example 1 Panel configuration Mode: General Entrance Panel Number: 0 To be dialled at panel: terminal address “TT TT TT”. For example “ ” Terminal address: Terminal address: Power supply Adaptor 3243

35 Panel configuration (3) DUOX Technical Department Panel (9) Example 2 Panel configuration Mode: General Entrance (Dial at panel: “TT TT TT”. For example “ ”) Panel Number: 0 Terminal address: VDC Panel configuration Mode: Block / Block Number: 00 (Dial at panel: “TT TT”. For example “00 03”) Panel Number: 0 Terminal address: Panel configuration Mode: Block / Block Number: 01 (Dial at panel: “TT TT”. For example “00 03”) Panel Number: VDC VDC VDC VDC VDC VDC

36 DUOX Technical Department Panel configuration (4) Panel (10) Panel configuration Mode: General Entrance (Dial at panel: terminal “BB SS TT”. For example “ ”) Panel Number: 1 Terminal address: Sub-Block 04 Panel Number: 0 Panel configuration Mode: Block, Number 01 Panel Number: 0 Panel configuration Mode: Block, Number 02 Panel Number: 0 Panel configuration Mode: Block, Number 00 Panel Number: 0 Example 3 Block 00 PSU 3243 PSU 3243 PSU 3243 PSU 3243 General Entrance (GE) GE, Panel 0 GE, Panel 2GE, Panel 3 Block 01 Block 99 Sub-Block 04 GE, Panel 1 Sub-Block 00 PSU 3243 PSU 3243 PSU 3243

37 DUOX Technical Department Panel (11) The parameters of the outdoor panel can be programmed from keypad, by entering the configuration mode: “A” + “4444” (Confirmation tone “beep-beep” is heard) + Command number (See table) + Value. Panel configuration from Direct Keypad Command Number Parameter Possible values [By default] Comment 01Door Opening time 01-99”. Opening from telephone or access control [03] 02Door Opening time from Exit button 00-99”. Door Relay activation from exit button (Terminal "BS") [06] 03Mode of panel 0-Sub-Block Mode of panel configuration [1]-Block 2- General Entrance 04Block Number The panel belongs to this block number [00] 05Sub-Block Number The panel belongs to this Sub-block number [00] 06Panel Number 0..9 Panel Number [0] 07Sensor Door Time Max.time that door can remain released since opening [00] (not acitve) 08Openinig Code Opening code from keypad [AAAA](not active) 09Programming access code Programming access code [4444] 10Master panel mode [0]- No To program telephones 1- Si 11Guard unit mode0 Resets to night mode when this option is selected 12Volume of confirmation tone at panel 0..9 Adjustment of the confirmation tone at panel [5] 13Parameters Reset [0] No reset 1 Reset It recovers the default values when this option is selected 14Camera Adjustment0-9 [9]Selection from monitor of different areas

38 DUOX Technical Department Panel (12) CONTINOUS PROFILE AMPLI (+2441): Only 5 PINS Panel configuration from Direct Keypad SKYLINE or KEYPAD/DISPLAY AMPLI: 6 PINS

39 ASSISTED CONFIGURATION BY VOICE IN PUSHBUTTONS PANELS DUOX Technical Department Panel (13)

40 Panel configuration (1) DUOX Technical Department Panel (14) A._ PANEL MODE: At the amplifier label the installer will register the selected values. For example: Programming the panel as Sub-Block 2, and panel number 3, Belonging to block 1. B._ CAMERA ADJUSTMENT. As well with a Direct keypad Ref.7439 or with a programmer Ref.3254, the Camera Adjustment is configured at amplifier. Each of the values represents the video areas that will be captured by the camera. The value 9 (By default is the complete image).

41 STEPACTIONPICTURERESULT 1 Set the panel as MASTER and program the terminal from the Master panel. (See slide “Terminal programming”) 2 Enter the ‘inverse programming' mode on the DUOX by keeping pressed “SW1” button during 10 sec, until 1 beep is heard and the led “DL2” blinks once per second. 3 Assign the new addresses to each button: 3.1 Press the programming button at the terminal until the programming tone is heard, and with the handset hang… DUOX Technical Department Panel (15) How to program the Mapping Call Code: “Inverse” programming: In case that NON SEQUENTIAL CODES are necessary Mapping is an advanced programming function available in panels with pushbuttons. It allows the modification of the call code assigned based on their position on the call extension module or button module. ‘Beep’ DUOX address stored at terminal memory Press the “SW1” button, 10” “DL2” Led blinks Programming tone

42 DUOX Technical Department Panel (16) How to program the Mapping Call Code: “Inverse” programming (Continuation) STEPACTIONPICTURERESULT 3.2 …Press the call button associated with this terminal (apartment) on the entry panel. The address previously programmed on that terminal will be assigned to the button (it will be stored on the amplifier). Repeat for all the terminals 3.1/ Exit Programming: Press the “SW1” button again. Anyway the amplifier will automatically exit the programming mode after 5 minutes of inactivity. DEPENDING ON THE RANGE OF THE CODES, THE AMPLI HAS TO BE SET AS SUBLOCK/BLOCK OR GEN.ENT. TO RESET THE MAPPING: Switch-OFF and Switch-ON keeping press “SW1” during 5 sec. Remember that the default call order is from bottom to top and from right to left. Mapping code stored at amplifier Panel at stand-by status Press the “SW1” button

43 STEPACTIONPICTURERESULT 1 Set the panel as MASTER. 2 Select the «sequential programming» mode by keeping pressed “SW1” button. After 10 seconds a first “beep” is heard, keep pressing during still 5 sec. until 2 beeps are heard and the “DL2” led blinks once per second. 3 Assign the new addresses to each button: Press the call buttons in whatever order you wish, to assign the codes on the entry panel, starting with 1st press=“Code 0”, 2 nd press=“Code 2” and running sequentially to the last required number. 4 Exit Programming: Press the “SW1” button again. Anyway the amplifier will automatically exit the programming mode after 1 minute of inactivity. DUOX Technical Department Panel (17) How to program the Mapping Call Code: “Sequential” programming (Only 1 operator) Mapping code stored at amplifier Panel at stand-by status Press the “SW1” button “DL2” Led blinks ‘Beep’ Press the “SW1” button ‘Beep’ Press 3 times consecutively the “SW1” button

44 DUOX Technical Department Terminals (1) CITYMAX Basic DUOX Telephone LOFT Basic DUOX Telephone LOFT Basic Plus DUOX Telephone LOFT Extra DUOX Telephone Ref. 3425Ref. 3420Ref. 3421Ref Terminals: B, B B, B, T, A, -B, B, T, A, -, F1, F2 Melody selection Door bell Call Extender Light&Buzzer activator Melody selection Door bell Call Extender Light&Buzzer activator Call volume regulator Mute mode F1 and F2 buttons Stand-by Cons.: 16mA Stand-by Cons.<20mA Max.Consumpt.: 280mA Max.Consumpt.: 300mAMax.Consumpt.: 320mA

45 Loft Color Monitor Door opening DUOX Technical Department Terminals (2) AutoSwitch-ON: To Block panel (“0” or “1”) or to General entrance panel (“0”) Additional function or Panic call Access to menu TECHNICAL FEATURES

46 Loft Color Monitor Connections DUOX Technical Department Terminals (3)

47 Loft Color Monitor Administrator’s Menu DUOX Technical Department Terminals (4) 1._ Monitor Programming (From panel or from monitor) 2._ Parameters Reset Monitor Pushbuttons

48 Loft Color Monitor User’s Menu DUOX Technical Department Terminals (5) 1._ Non disturb 2._ Melodies 3._ “F2” Additional function 4._ QR code A._ Video Adjustment (Bright/Contrast/Color): After AutoSwitch-ON (Or after call without taking communication) B._ Audio Adjustment: During communication Monitor Pushbuttons

49 Terminal Programming DUOX Technical Department Terminals (6) Note that the programming of the telephones will be performed from the Master panel. The procedure to set a panel as Master is following: Press 3 times consecutively the “SW1” button at the rear side of the amplifier, a confirmation tone (beep-beep) will be heard. To remove the Master mode, just press again 3 times consecutively the “SW1” button and a “Bop” tone will confirm it. In an installation only one panel at the same time can be Master. In case there is already a Master panel in the system, when another panel is set as Master, the previous one will be automatically removed from Master mode. ‘Beep’ Press 3 times consecutively the “SW1” button Step 1Step 2 To set the panel as Master ‘Bop’ Step 1Step 2 To remove the panel of Master Mode ‘Beep’ Press 3 times consecutively the “SW1” button

50 Loft Terminals Programming 1.Press the programming button and released it. 2.Confirmation tone is heard. 3.Press the corresponding pushbutton at the Master panel (or dial the apartment number in the keypad). 4.The confirmation tone is heard again. 5.The terminal will store the 6 digits of the panel call as DUOX address. DUOX Technical Department Terminals (7)

51 DUOX Technical Department Terminals (8) Melody Selection by installer at Loft Basic The telephone allows to select a different melody to distinguish when it is called from the outdoor panel or from the guard unit. The selection is done by the installer. MELODIES available: Bitone Fermax. Monotone Fermax. Monophonical Ding-Dong-Dang. Following steps to select the melody for panel call (All panels same melody): 1.At the telephone, press simultaneously the “programming” and the “door opening” button: The current telephone melody for a “panel call” is heard. 2.Pressing sequentially the “programming” button, the rest of melodies are heard. 3.After 10 sec.without presssing any button, the last melody performed will be stored. The exit of configuration is confirmed by a “beep”. Following steps to select the melody for guard unit call: 1.At telephone press simultaneously the “programming” and the “door opening” button during 5 seconds: The current telephone melody for a “guard unit call” is heard. 2.Pressing sequentially the “programming” button, the rest of melodies are heard. 3.After 10 sec.without presssing any button, the last melody performed will be stored. The exit of configuration is confirmed by a “beep”. 5 Sec.

52 Pick up the handset and after few seconds automatic communication is established with panel. DUOX Technical Department Terminals (9) Just after picking up the handset, any telephone programmed with a valid address “TT TT TT” will establish communication with the panel number “0” of its block. Under the condition that there is a free channel in that block and the panel “0” is available. From this moment, the behaviour will be the same as in an accepted call (Door opening available, 90 sec.of max.conversation time,…) If this feature is not wished, just change the number of the panel to a number different from “0”. If after picking up the telephone handset, the panel “0” is in communication with other telephone or there is another telephone of the same apartment in communication, a busy tone will be heard at the telephone. Autoswitch-on from the telephone to the panel number “0” of its Block PANEL “0”

53 Video Installations Accesses Backbone - Video Panels - Call extension module (according to panel model) - Surface or Flush Mounted Box - Lock Release First Step! Design the Installation! Power Supply Backbone - No of 18Vdc/1.5A Power Sources Ref Filter Ref.3243 = Panel + 12 Monitors or 20 Monitors - 12Vac/1.5A Sources= if a 12 Vac lock release is used - Monitors - Monitor connectors - Line terminations Obtain a Quote: Calculate a quote (1) DUOX Technical Department

54 Example – 1 DUOX Video SkyLine panel (buttons) to 40 monitors General Power Supply 3 x 4812 – 18 Vdc 1.5 A Power Supply. 3 x 3243 – Filter. 1 x 4800 – 12 Vac 1.5 A Power Supply. Accesses 2 x 7336 – S7 Frame (6V). 1 x 7391 – DUOX video module (W). 5 x 7371 – DUOX 8 push module (W). 2 x 8857 – S7 Flush Box. 1 x 8829 – Set of joining bolts (separators). 1 x 2541 – Connection cable. 1 x 3071 – 12 Vac Lock Release. Backbone 40 x 3412 –LOFT DUOX Monitor. 40 x 3415 –LOFT DUOX Monitor. 2 x 3255 – Line termination. Calculate a quote (2) DUOX Technical Department Example – 3 DUOX Video Skyline Direct panel to 50 colour monitors General Power Supply 5 x 4812 – 18 Vdc 1.5 A Power Supply. 5 x 3243 – Filter. 1 x 4800 – 12 Vac 1.5 A Power Supply. Accesses 3 x 7391 – DUOX video module (W). 3 x 7439 – VDS Direct keypad module (W). 6 x 7445 – Cardholder (W). 6 x 7334 – S5 SkyLine Frame (4V). 6 x 8855 – S5 Flushbox. 3 x 8829 – Set of joining bolts (separators). 3 x 3071 – 12 Vac Lock Release. Backbone 50 x 3412 –LOFT DUOX Monitor. 50 x 3415 –LOFT DUOX Monitor. 2 x 3255 – Line termination.

55 Example – 1 DUOX Video Marine Digital panel to 72 colour monitors General Power Supply 4 x 4812 – 18 Vdc 1.5 A Power Supply. 4 x 3243 – Filter. 1 x 4800 – 12 Vac 1.5 A Power Supply. Accesses 1 x 5483 – DUOX Marine Digital video panel. 1 x 5471 – Flushbox ST3. 1 x 3071 – 12 Vac Lock Release. Backbone 72 x 3412 –LOFT DUOX Monitor. 72 x 3415 –LOFT DUOX Monitor. 2 x 3255 – Line termination. Example – 4 DUOX Video City Direct panels to 32 colour monitors General Power Supply 5 x 4812 – 18 Vdc 1.5 A Power Supply. 5 x 3243 – Filter. 1 x 4800 – 12 Vac 1.5 A Power Supply. Accesses 4 x 7363 – City DUOX direct video panel. 4 x 7309 – City directory. 8 x 8855 – S5 Flushbox. 4 x 8829 – Set of joining bolts (separators). 4 x 3071 – 12 Vac Lock Release. Backbone 32 x 3412 –LOFT DUOX Monitor. 32 x 3415 –LOFT DUOX Monitor. 2 x 3255 – Line termination. Calculate a quote (3) DUOX Technical Department

56 DUOX Technical Department Questions?


Download ppt "FERMAX TECHNICAL SEMINAR. The Riser Panel Terminals Riser Basics Amplifier Configuration Models The Technical Book Why DUOX? System Summary How to make."

Similar presentations


Ads by Google