Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 November 2013 Oracle Converged Infrastructure - Technical Overview.

Similar presentations


Presentation on theme: "1 November 2013 Oracle Converged Infrastructure - Technical Overview."— Presentation transcript:

1 1 November 2013 Oracle Converged Infrastructure - Technical Overview

2 2 THE WORKFORCE IS CHANGING Access to information, anytime & anywhere Ability to try and “succeed or fail” quickly Business virtualization enables companies to compete anytime & anywhere Business is becoming collaboration focused rather than location focused Exploit advanced data models and analytics Business innovation is technology dependent

3 © 2013 VCE Company, LLC. All rights reserved. IMPERATIVES: AGGREGATION/CONSOLIDATION OF PROJECTS – APPLICATION MODERNIZATION/RATIONALIZATION & BI ANALYTICS – Rethinking database investments Agile and automated infrastructure Shared infrastructure for all apps Resilient and scalable infrastructure Rapid provisioning of new services Application flexibility and cost transparency Always-on IT systems 3 TOP BUSINESS IMPERATIVES AND IT PROJECTS LINE OF BUSINESSIT TEAM Enterprise Growth Attract and Retain Customers Operational Efficiency Reduce Costs Improved IT Applications and Infrastructures

4 © 2013 VCE Company, LLC. All rights reserved. TURNING BUSINESS PAINS INTO OPPORTUNITIES RETHINKING DATABASE INVESTMENTS  Difficult to architect for Hybrid IT  Imbalance – standardize/ customize  Legacy operating model Optimize infrastructure  Hard to aggregate more apps/BI  Time and effort for onboarding and upgrade  Heterogeneity – source to target, bare metal or virtual Aggregate and rationalize applications/BI analytics  Low latency for increasing transaction volume  Increased concurrency with better response time  Too long to go from QA, Dev, and Production Speed as in use of data 4 Exploit compute, storage, and networking capabilities Interlinked applications and databases to support growth, operational models, and drive customer demand Technology-enabled innovation is mandatory – Data as an asset with increased User Community

5 5 Converged Infrastructure. Single Product. Single Point Of Management. Single Point Of Support. Vblock TM

6 6 OLTP & Data Warehouse 3.7 Million Read IOPS 0.5mS Latency Vblock TM New

7 © 2012 VCE Company LLC, All rights reserved. Upside of VCE + Virtualization WHY MIGRATE AND VIRTUALIZE WORKLOADS Upside of Virtualization Consolidation Allows multiple application servers to be consolidated onto single machines Ease of Provisioning Virtual images are easily duplicated/moved Manageability Migration tools such as vMotion allow for seamless, zero-downtime management of all application tiers Availability Integrated High Availability capabilities increase service level agreements (SLAs) All Benefits of Virtualization PLUS Faster Procurement Times Solutions is pre-integrated, pretested, and pre-validated for faster time to market Reduced Management Complexity Unified management frameworks reduces the complex activity of managing Tier-1 landscapes Seamless Support Comprehensive, integrated support that encompasses all aspects of Vblock Infrastructure Platforms

8 © 2013 VCE Company, LLC. All rights reserved. 8 WHY CUSTOMERS RUN ORACLE ON VBLOCK™ SYSTEMS TODAY? Pre-Engineered, Pre-Validated, Pretested Vblock Systems Speed deployment Aggregate workloads Optimize and standardize infrastructure Lower operational cost Secure environment Promote innovation Virtualization Reduce HW/SW costs Consolidate licenses Increase utilization Provision faster Improve quality of service and availability

9 © 2013 VCE Company, LLC. All rights reserved. PROVIDING SIMPLE SCALABILITY Physical Build –What equipment is used in system –How equipment is racked in system Base Logical Build –What software is used on system components –How software base configuration is deployed –How equipment is connected in system Logical Build Customization –How the systems advanced configuration is implemented for customer standards / requirements –How the systems advanced configuration is optimized for customer application/workload What We Do… Pre-Engineered Pre-integrated Accelerates The Journey

10 © 2013 VCE Company, LLC. All rights reserved. RESULTS OF SEPTEMBER 2013 IDC RESEARCH STUDY 10 VCE CUSTOMER BENEFITS  25 days down to 5 days 5X FASTER TIME FOR NEW SERVICES 50% REDUCTION OF ANNUAL DATA CENTER COSTS  160 days down to 40  79% less staff effort 4X FASTER TIME TO DEPLOYMENT 96% REDUCTION IN DOWN TIME

11 © 2013 VCE Company, LLC. All rights reserved. TRUE CONVERGED INFRASTRUCTURE 11 VBLOCK™ SYSTEMS SYSTEM 720 SYSTEM 200 SYSTEM 100 SYSTEM 340 SPECIALIZED SYSTEMS VCE Vision ™ Intelligent Operations software

12 © 2013 VCE Company, LLC. All rights reserved. 12 INTRODUCTION TO VBLOCK™ SPECIALIZED SYSTEM FOR HIGH-PERFORMANCE DATABASES  High availability  Over 3.7 Million IOPS for OLTP, DW and mixed workload environments  Latency of less than ½ Millisecond  Sustained throughput of 32GBs  Data load rate of 21TB/hr  Multi-database version support  Lifecycle System Assurance  Integrated data protection options  Lower TCO—operations and licensing  Architected for high-performance databases (Oracle)  Increases productivity of Oracle applications and database teams

13 © 2013 VCE Company, LLC. All rights reserved. 13 WHAT IS UNIQUE ABOUT VBLOCK™ SPECIALIZED SYSTEM FOR HIGH-PERFORMANCE DATABASES? VMAX 40K Optimized EFD. FAST VP. High-performance and high-capacity options available DATABASE SERVER Cisco C240 M3: 2-, 4-, or 8-server options NETWORK Nexus 5K, MDS, advanced networking configurations NEXT-GEN VNX 8000/7600/5800 Optimized EFD. FAST VP. High-performance and high-capacity options available Server Flash—XtremSF/XtremSW for scale, application coherence, and RAC OPTIONAL APPLICATION SERVER Cisco C220 M3: 2-, 4-, or 8-server options Choose VMAX and/or VNX based on technical fit, skillset, and governance relations, the world’s most trusted storage platform 1 Server flash for high IOPS and low latency, tuned with storage flash 2 Aggregate mission- critical applications and BI/DW with high-performance databases 3 Minimize loss and latency overhead, and maximize bandwidth 4 Mix virtual or bare metal workloads across the development, QA, and production lifecycles 5 Exploit Vblock System advantage – availability, lifetime assurance, ease of scaling, etc.

14 © 2013 VCE Company, LLC. All rights reserved. 14 VBLOCK™ SPECIALIZED SYSTEM FOR HIGH- PERFORMANCE DATABASES: HARDWARE SUMMARY VMAX—8 NODEVMAX—4 NODEVNX—8 NODEVNX—4 NODEVNX—2 NODE Database servers (C240— ES-2690, 2.9GHz) Database server cores Database server RAM6144 GB3072 GB6144 GB3072 GB1536 GB XtremSF 700 GB SLC Application servers (C220)Optional 2, 4, and 8 nodes Networking Cisco MDS 9710 (8-database server config) /9250i (2- and 4-databaser server config) FC SAN switches Cisco Nexus 5548UP Ethernet switches Cisco 6248 fabric interconnects Cisco 2232PP fabric extenders Cisco Nexus 3048 switches Storage typeVMAX 40KVNX 8000VNX 7600VNX 5800 Raw Storage Capacity High Performance 141 TB71 TB100 TB50 TB25 TB High Capacity 589 TB295 TB518 TB259 TB98 TB Updated on 11/5/13

15 © 2013 VCE Company, LLC. All rights reserved. PERFORMANCE RESULTS FROM VBLOCK SYSTEM, SEPTEMBER VBLOCK™ SPECIALIZED SYSTEM FOR HIGH- PERFORMANCE DATABASES METRIC VBLOCK SYSTEM 8-NODE C240 SERVERS WITH XTREMSF (2 PER SERVER, 16 TOTAL) AND XTREMCACHE ON VMAX 40K High Performance DisksHigh Capacity Disks Maximum Disk Bandwidth32 GB/s Maximum Achieved System IOPS940,000 Disk Data Capacity (RAW)141 TB589 TB Maximum Flash Read IOPSOver 3.7 Million IOPS Average Service Time (or Latency)Less than ½ Millisecond DB Server Flash Data Capacity (RAW)11.2 TB Maximum Data Load Rate21 TB/hour Sustained Throughput32TB/hr VCE makes no representation and undertakes no obligation with regard to product planning information, anticipated product characteristics, performance specifications or anticipated release dates (collectively, “Roadmap Information”). Roadmap information is provided by VCE as an accommodation to the recipient solely for purposes of discussion and without intending to be bound thereby.

16 XTREMSF ADVANTAGES Performance Flexibility Efficiency Dramatic improvements in application latency and throughput—up to 1.13 million IOPS Broad range of eMLC and SLC capacities for use as local storage or with XtremCache – 2x700GB SLC chosen Best TCO—lowest overhead, highest performance, lowest power consumption, best density 16

17 XTREMCACHE: SOFTWARE PERFORMANCE AND PROTECTION Performance Intelligence Protection Dramatic improvements in latency and throughput Extends EMC FAST architecture into the server Backed by intelligent, resilient, highly available storage 17

18  Reads are serviced by XtremCache for  Writes are passed through to the storage array for Reads (latency: <100 μs) 2 8 Writes Flash FC / SAS SATA / NL-SAS SATA / NL-SAS XTREMCACHE ADVANCED ARCHITECTURE 18

19 XTREMCACHE 2.0 – ORACLE RAC SUPPORT Requires XtremCache and above Cache-Coherency Roles & Responsibilities: RAC still owns database content coherency (rows/columns) XtremCache owns LUN block coherency Optimized, sends metadata between nodes Uses SCSI-3 PGR for nodes membership transitions Cooperate with Oracle clusterware Oracle RAC Nodes Oracle Clients XtremCache & XtremSF LUN Shared Volumes LUN

20 © 2013 VCE Company, LLC. All rights reserved. 20 INTEGRATED DATA PROTECTION OPTION VBLOCK TM DATA PROTECTION  Continuous availability, best-in-class system uptime  Advanced de-duplication  Optimum resource utilization  Eliminate risk, faster time to value  Support for entire Vblock Systems portfolio EMC RecoverPoint Avamar 7 plus Data Domain EMC VPLEX (For Vblock™ Specialized System for High-Performance Databases in 2014)

21 © 2013 VCE Company, LLC. All rights reserved. Data Domain― DD Boost Software Avamar NetWorker Third-party Backup Applications  Less storage for backup – deduplication  Speed up backups 50% with DD Boost Software  Less bandwidth  Reliable recovery  Control and visibility 21 BACKUP AND RECOVERY FOR ORACLE INTEGRATED SOLUTIONS TAKES ORACLE PROTECTION TO NEXT LEVEL ORACLE-optimized interfaces

22 22 Performance Driven Purpose Built Fully Integrated Flash Everywhere Fully Automated Storage Tiering Physical or Virtual Optional Add-Ons: Data Domain, VPLEX (Coming in 2014), RecoverPoint, Replication Manager Oracle SQL Server DB2 OLTP Data Warehouse Hybrid DATABASE WORKLOAD Specialized System – Open Hardware Architecture Physical VMAX VNX Virtual VMAX VNX Vblock™ Specialized System for High- Performance Databases

23 23 Standard Platform Software RHEL V6.3 PowerPath V5.7 XtremCache V2.0.1 Cisco MDS Enterprise VCE Vision (VB300, VB700) UniSphere management and FAST Suite ProSphere management and FAST Suite Hardware Platforms Cisco UCS C240M3 Servers XtremSF PCIe Flash Cache Blades Cisco MDS & Nexus Switches VNX (5800, 7600, 8000) Storage Arrays – FAST Cache, SSD, SAS, NL SAS VMAX 40K (4-Engine, 8-Engine) Storage Arrays - SSD, FC, SATA Vblock TM for High Performance Databases

24 24 Vblock™ Specialized System for High Performance Databases

25 25 Vblock™ Specialized System for High Performance Databases

26 26 Vblock™ Specialized System for High Performance Databases - Competitive Advantages Supports Oracle, SQL Server, & DB2 Supports Oracle RAC Clusters Supports Physical or Virtual Delivers Higher Availability Delivers Over 3.7 Million “sustained” IOPS Delivers Less than ½ Millisecond I/O Latency Delivers 32GB/s Sustained Throughput Delivers 21TB/hr Data Load Delivers 2.5X more Usable Capacity Delivers Active-Active Balanced Bandwidth Does not Require 3-Way Database Mirroring Delivers Fully Automated Storage Tiering Delivers Server & Storage Non-Disruptive Upgrades Optional Server Add-On s for Applications and additional workloads Optional Federated Database Clones & Snaps Optional Logical & Physical Database Protection Optional Federated Multi-Site Replication Optional Federated Data Domain Backup Delivers 26% Lower Total Cost of Ownership

27 27 Vblock Enablement Services Unclear application workload migration strategy Separate operational silos Incomplete cloud delivery model 0 Service Catalog Definition Operational Integration Application Workload Migration System integrated into data center Integrated operational processes and tools Accelerated cloud delivery model to transform to ITaaS

28 28 Advancing the Execution of Your Cloud Strategy EMC Vblock Enablement Services Vblock Architecture & Activation Deploy System, Layout Resources, Connect to Enterprise Vblock Service Enablement Service Blueprint for IaaS, Define Service Catalog Vblock Population Migrate Application Workloads Vblock Integration Integrate with Operational Processes & Tools Discovery & Analysis Define Application Workloads, Capacity Assessment, Virtualization Assessment Vblock Jumpstart Service

29 29

30 30 EMC Community for Oracle DBAs DBA Flash & More Storage Visibility and Control Oracle Performance Faster Deployment, Higher Availability & Lower IT Costs Oracle Converged Infrastructure DBA Control of Backup, Recovery and Replication Oracle Backup & Recovery Logical and physical recovery and active- active availability Oracle Continuous Availability EMC Virtual Infrastructure for Oracle DBA Optimize Oracle Infrastructure & Maximize DBA Productivity

31

32 32 Vblock™ Specialized System for High Performance Databases Configuration Comparisons

33 33 Key Technical Positioning Comparison Metrics Read Flash IOPS = 1.5M GB/s Throughput = 25GB/s Data Load Rate = 12TB/hr Read Flash Over 3.7Million IOPS Latency of less than ½ Millisecond Sustained Throughput 32GB/s Data Load Rate 21TB/hr VS 512 Cores from Exadata vs 128 Cores from VBLOCK Specialized System for Equal IOPS Performance

34 34  Cisco UCS C240M3 Server  (Per Server) - PowerPath V5.7, RHEL V6.3  Cisco MDS Switch –(2) Enterprise License Key (MDS9200) (2 & 4 Server Configs) –(2) Enterprise License Key (MDS9700) (8 Server Configs)  VNX Storage –VCE Vision for VB300 (VNX), Unisphere management and FASTVP Suite  VMAX Storage –VCE Vision for VB700 (VMAX), ProSphere management and FASTVP Suite Vblock™ Specialized System for High- Performance Databases Standard Platform Software

35 35 Vblock™ Specialized System for High- Performance Databases 2 Server Configuration for VNX

36 36 © 2013 VCE Company, LLC. All rights reserved. Detail 2 database server VNX (HP) 36 + Compute  1 x 42RU Cabinets  2 x C240-M3, 768GB  2 x UCS 6248UP  2 x Nexus 5548UP Management  2 x C220-M3 LMI  2 x Cisco Nexus 3048 VLANs (VIC 1225)  101 OOB Mgmt  105 Oracle Public  113 Oracle Private Interconnect  119 Oracle Cluster VIP Storage & SAN  2 x MDS 9250i (16 Gbps)  VNX DPE + 5 x DAE’s  FAST Cache – 100 GB EFD x 8  FAST VP T1 – 200 GB EFD x 20  FAST VP T2 – 300 GB 15K SAS x 38  FAST VP T3 – 600 GB 10K SAS x 16  25TB RAW, 18TB Usable Software  Redhat Enterprise 6.3  XtremCache  Oracle RAC 11g, 12C Field Installed

37 37 © 2013 VCE Company, LLC. All rights reserved. Detail 2 database server VNX (HC) 37 + Compute  1 x 42RU Cabinets  2 x C240-M3, 768GB  2 x UCS 6248UP  2 x Nexus 5548UP Management  2 x C220-M3 LMI  2 x Cisco Nexus 3048 VLANs (VIC 1225)  101 OOB Mgmt  105 Oracle Public  113 Oracle Private Interconnect  119 Oracle Cluster VIP Storage & SAN  2 x MDS 9250i (16 Gbps)  VNX DPE + 5 x DAE’s  FAST Cache – 100 GB EFD x 8  FAST VP T1 – 200 GB EFD x 20  FAST VP T2 – 900 GB 10K SAS x 30  FAST VP T3 – 1000 GB 7.2K NL-SAS x 64  98TB RAW, 75TB Usable Software  Redhat Enterprise 6.3  XtremCache  Oracle RAC 11g, 12C Field Installed

38 38 4 Server Configuration for VNX Vblock™ Specialized System for High- Performance Databases

39 39 DETAIL 4 DATABASE SERVER VNX (HP) + Compute  2 x 42RU Cabinets  4 x C240-M3, 768GB  2 x UCS 6248UP  2 x Nexus 5548UP Management  2 x C220-M3 LMI  2 x Cisco Nexus 3048 VLANs (VIC 1225)  101 OOB Mgmt  105 Oracle Public  113 Oracle Private Interconnect  119 Oracle Cluster VIP Storage & SAN  2 x MDS 9250i (16 Gbps)  VNX DPE + 11 x DAE’s  FAST Cache – 100 GB EFD x 20  FAST VP T1 – 200 GB EFD x 40  FAST VP T2 – 300 GB 15K SAS x 76  FAST VP T3 – 600 GB 10K SAS x 32  50TB RAW, 36TB Usable Software  Redhat Enterprise 6.3  XtremCache  Oracle RAC 11g, 12C Field Installed

40 40 DETAIL 4 DATABASE SERVER VNX (HC) + Compute  2 x 42RU Cabinets  4 x C240-M3, 768GB  2 x UCS 6248UP  2 x Nexus 5548UP Management  2 x C220-M3 LMI  2 x Cisco Nexus 3048 VLANs (VIC 1225)  101 OOB Mgmt  105 Oracle Public  113 Oracle Private Interconnect  119 Oracle Cluster VIP Storage & SAN  2 x MDS 9250i (16 Gbps)  VNX DPE + 11 x DAE’s  FAST Cache – 100 GB EFD x 18  FAST VP T1 – 200 GB EFD x 40  FAST VP T2 – 900 GB 10K SAS x 60  FAST VP T3 – 3TB 7.2K NL- SAS x 64  259TB RAW, 201TB Usable Software  Redhat Enterprise 6.3  XtremCache  Oracle RAC 11g, 12C Field Installed

41 41 8 Server Configuration for VNX Vblock™ Specialized System for High- Performance Databases

42 42 DETAIL 8 DATABASE SERVER VNX (HP) + Compute  3 x 42RU Cabinets  8 x C240-M3, 768GB  2 x UCS 6248UP  2 x Nexus 5548UP Management  2 x C220-M3 LMI  2 x Cisco Nexus 3048 VLANs (VIC 1225)  101 OOB Mgmt  105 Oracle Public  113 Oracle Private Interconnect  119 Oracle Cluster VIP Storage & SAN  2 x MDS 9710 (16 Gbps)  VNX ; 16 DAEs  FAST Cache – 100 GB EFD x 40  FAST VP T1 – 200 GB EFD x 80  FAST VP T2 – 300 GB 15K SAS x 152  FAST VP T3 – 600 GB 10K SAS x 64  100TB RAW, 71TB Usable Software  Redhat Enterprise 6.3  XtremCache  Oracle RAC 11c field Installed

43 43 DETAIL 8 DATABASE SERVER VNX (HC) + Compute  3 x 42RU Cabinets  8 x C240-M3, 768GB  2 x UCS 6248UP  2 x Nexus 5548UP Storage & SAN  2 x MDS 9710 (16 Gbps)  VNX ; 16 DAEs  FAST Cache – 100 GB EFD x 40  FAST VP T1 – 200 GB EFD x 80  FAST VP T2 – 900 GB 10K SAS x 120  FAST VP T3 – 3 TB 7.2K NL-SAS x 128  518TB RAW, 402TB Usable

44 44 4 Server Configuration for VMAX Vblock™ Specialized System for High- Performance Databases

45 45 DETAIL 4 DATABASE SERVER VMAX + Compute  1 x 42RU Cabinets  4 x C240-M3, 768GB  2 x UCS 6248UP  2 x Nexus 5548UP Management  2 x C240-M3 LMI  2 x Cisco Nexus 3048 Storage & SAN  2 x MDS 9250i (16 Gbps)  VMAX 40K – 4 engines (192GB Cache per engine – 768GB total)  FAST VP T1 – 100 GB EFD x 132  FAST VP T2 – 300 GB 15K SAS x 200  FAST VP T3 – 1 TB 7.2K NL-SAS x 230 (optional – part of HC offering)  Raw capacity 71 TB (HP); 295 TB (HC)

46 46 8 Server Configuration for VMAX Vblock™ Specialized System for High- Performance Databases

47 47 DETAIL 8 DATABASE SERVER VMAX Compute  2 x 42RU Cabinets  8 x C240-M3, 768GB  2 x UCS 6248UP  2 x Nexus 5548UP Management  2 x C240-M3 LMI  2 x Cisco Nexus 3048 Storage & SAN  2 x MDS 9710i (16 Gbps)  VMAX 40K – 8 engines (192GB Cache per engine – 1536GB total)  FAST VP T1 – 100 GB EFD x 262  FAST VP T2 – 300 GB 15K SAS x 392  FAST VP T3 – 1 TB 7.2K NL-SAS x 458 (optional – part of HC offering)  Raw capacity 141TB (HP); 589TB (HC)


Download ppt "1 November 2013 Oracle Converged Infrastructure - Technical Overview."

Similar presentations


Ads by Google