1 WireLess TelNet 52 – Tutorial - Common cases of configuration www.softogo.com Tn52 (5250 / 3270) Tutorial Common cases of configuration.

Similar presentations


Presentation on theme: "1 WireLess TelNet 52 – Tutorial - Common cases of configuration www.softogo.com Tn52 (5250 / 3270) Tutorial Common cases of configuration."— Presentation transcript:

1 1 WireLess TelNet 52 – Tutorial - Common cases of configuration Tn52 (5250 / 3270) Tutorial Common cases of configuration

2 2 WireLess TelNet 52 – Tutorial - Common cases of configuration WTn52 -> emulation 5250 / 3270 Define the emulation 52 / VT 5250 (SNA LU 6.2) , , etc. AS400 / iSeries / i5 (OS/400) 3270 (SNA LU 3) , , etc. IBM/3090 S/390 (System/370) WTnVT -> emulation VT, ANSI, SSH Not in this document! Telnet VT VT100, VT220, ANSI, etc. Win /UNIX SSH Xterm, VTxxx, etc. UNIX / Linux Open the WTnVT (UNIX / Windows) Tutorial

3 3 WireLess TelNet 52 – Tutorial - Common cases of configuration License activation Configuring the emulator IBM Family 5250 / 3270 Keyboard mapping Touch screen actions Display configuration Barcode reading Error messages Advanced configuration Table of contents

4 4 WireLess TelNet 52 – Tutorial - Common cases of configuration

5 5 Options: On-line, by Internet connection. license request. Demo mode: Telnet sessions disconnect itself after 5 minutes. Document License activation guide License activation License activation may be performed using a desktop PC or directly with the PDA if the device has internet connection availability

6 6 WireLess TelNet 52 – Tutorial - Common cases of configuration

7 7 Access to the emulator configuration Start > WireLess TelNet WCE 5250 > TelNet Clients - Default Profile > (PDA model) Emulator configuration is stored in files on the PC. At each modification they will be copied to the PDA How to configure the emulator? Change the configuration, i./e.: [ TN52_EMULATION] DragDisplay = Yes Download configuration to the PDA Restart the program to read new configuration 4 4 Configuration Configuration download by ActiveSync 2 2

8 8 WireLess TelNet 52 – Tutorial - Common cases of configuration

9 9 Family 5250 or (SNA LU 6.2) , , etc. AS400 / iSeries / i5 (OS/400) 3270 (SNA LU 3) , , etc. IBM/3090 S/390 (System/370) Configuration (Generic File) [SESSION_0] TTypePreferred= EmulationTylpe=5250. Configuration (Generic File) [SESSION_0] TTypePreferred= E EmulationTylpe=3270.

10 10 WireLess TelNet 52 – Tutorial - Common cases of configuration

11 11 WireLess TelNet 52 – Tutorial - Common cases of configuration How-to configure the keyboard mapping? Keyboard Mapping In the 5250 configuration SCANCODE of the key to be mapped 520 Action TIP! -> In the configuration file 5250 actions ( AID, Function, Control, Cursor, Signal) are grouped by topic: [TN52_AID_KEYS] 5250 Functions (They generate transactions with the host) [TN52_CONTROL_KEYS] (They can -or cannot- generate host transactions) [TN52_CURSOR_KEYS] Cursor movements (They do not generate host transactions) On-line help

12 12 WireLess TelNet 52 – Tutorial - Common cases of configuration You need to: Identify the 'scancode‘ of the key or keystroke to be mapped to a 5250 action It is possible to map any keystroke to any 5250 action Keyboard Mapping TIP! -> Identify the scan code: In the “Keyboard Test” dialog on the PDA it is possible to check the scan code generated by any key. Configuration > Keyboard Test ‘To->5250’ / ‘To->3270’ Configuration The changes are done in the configuration file. Access it from installation page. On-line help

13 13 WireLess TelNet 52 – Tutorial - Common cases of configuration Keyboard Mapping Warning. Unless you know exactly what you are doing, please do not modify this section. [TN52_SIGNAL_KEYS] Specific AS400 diagnostic control actions Advanced configuration Other keys Mapping Configuration (5250 file) [TN52_KEY_MAP] Allow mapping from one key to another key (instead of 5250 actions). Example: Mapping characters that are not in the PDA keyboard. Press “Esc+5” to make a “-” (minus) TIP! -> Some examples One finger: In some keyboards it is needed to use both hands to enter F1. It is possible to avoid this by a customized keystroke mapping. F16 How-to enter F16?. This key does not exist in my PDA keyboard! Suggestion, map as: Control+D = F16 On-line help

14 14 WireLess TelNet 52 – Tutorial - Common cases of configuration

15 15 WireLess TelNet 52 – Tutorial - Common cases of configuration With the touch screen, the stylus or the fingers, it is possible to perform actions Touch screen actions Display scroll Scroll the display in the virtual screen by moving the stylus. Allow to scroll the visible part of the emulated screen in the display to view all the content. Configuration (5250 file) [TN52_EMULATION] DragDisplay = Yes Available features Cursor by tapping Move blinking cursor between input fields. Operation It allows to change the input cursor position with the stylus by pressing directly on the input field. Configuration (5250 file) [TN52_EMULATION] CursorByTap = Yes On-line help

16 16 WireLess TelNet 52 – Tutorial - Common cases of configuration With the touch screen, the stylus or the fingers, it is possible to perform actions Touch screen actions 5250 Functions at screen Send a function key to the AS400 Host by touching the screen. Using the stylus you can touch any "Fx“ text on the screen. (x= is the function number). i./e.: if the text reads “F5”, when touching over this text, emulator sends PF5 function to Host. Configuration (5250 file) [TN52_EMULATION] FunctionByTap = Yes Available features On-line help

17 17 WireLess TelNet 52 – Tutorial - Common cases of configuration With the touch screen, the stylus or the fingers, it is possible to perform actions Touch screen actions Available features Double Tap With a double tap on the screen, you can generate any keystroke, which also can be a function. Operation Touch two times the screen in the same place, then remove the stylus. Configuration (5250 file) [TN52_EMULATION] DoubleTap=00XX (scan code of the key) Example of use It is possible to configure the “double tap” to launch the virtual keyboard (SIP Panel) on the screen. SipScanCode (Use the same code than DoubleTap – 00FF for example) It is also possible to generate: Functions Enter Letters / digits On-line help

18 18 WireLess TelNet 52 – Tutorial - Common cases of configuration

19 19 WireLess TelNet 52 – Tutorial - Common cases of configuration Configure it by changing the font size in the current session Display configuration 2. See the resulting configuration in the PDA Go to configuration dialog and see the currently selected size and font. 3.Make the configuration persistent Change the configuration on the PC. On the 5250 configuration file [DISPLAYFONT] FullName= Size= On-line help 1.Try the different sizes in the active session In the active session, on the menu “Tools”, with “Text Size +” and “Text Size –” is possible to dynamically change the font size. On-line forumOn-line help

20 20 WireLess TelNet 52 – Tutorial - Common cases of configuration Configure it by changing the number of visible rows / columns on screen Display configuration Font and size Try different layouts with different fonts and sizes. Warning. Prefer fixed width fonts (monospaced) Font Examples Example 1 Example 2 Example 1Example 2 Font Examples Example 1 Example 2 Example 1Example 2 TIP 1. Test it in the PDA Connect emulator to Host. With the menu “Go” / “main“, go back to main menu. Go to [configure] / [Display Configuration], change the value in the combo-box, then click on [select]. 2. Make the configuration persistent Configuration option (generic file) [DISPLAYFONT] FullName= Size= On-line forum Indicator shows rows and columns following the selected configuration On-line help

21 21 WireLess TelNet 52 – Tutorial - Common cases of configuration Show colors in the PDA as you see in the PC Display colors Explanation: Color display varies following the emulated terminal model (monochrome) and (color). CONFIGURATION (generic file) [SESSION_1] TtypePreferred= On-line help On-line forum

22 22 WireLess TelNet 52 – Tutorial - Common cases of configuration

23 23 WireLess TelNet 52 – Tutorial - Common cases of configuration Read a barcode, then split or truncate it to fill one or some input fields Split the barcode CONFIGURATION (5250 file) Configure the action to perform with the barcode read. Configuration option [TN52_BARCODES] BcInField Options The 'S‘ setting SPLITS the barcodes exceeding the current input field width. That action allows to fill the following fields. By default, the configuration is 'T‘. This setting TRUNCATES the exceeding data and always fills only one field (the current one). Aide on-line

24 24 WireLess TelNet 52 – Tutorial - Common cases of configuration CONFIGURATION (5250 file) Configure the action to perform after barcode reading. Configuration option [TN52_BARCODES] PostAction Read a barcode, then send [ENTER] instead of [Field Exit] ENTER instead of FieldExit The FieldExit function performs a “Field Adjust“ then moves to the next field (if any). (That action performs an ENTER if the field is AUTO-ENTER). The ENTER function performs a “Field Adjust" then send screen data to Host (AID key). Aide on-line Warning Do not add suffixes to barcode! Use prefixes and suffixes only to add text.

25 25 WireLess TelNet 52 – Tutorial - Common cases of configuration

26 26 WireLess TelNet 52 – Tutorial - Common cases of configuration It is possible to show the 5250 bottom message line as a Pop-Up message Message line CONFIGURATION (5250 file) [TN52_ERROR_MSG] NoMsgLine Options Yes= Do not show the message line as a pop-up. No= Show the message line as a pop-up On-line help

27 27 WireLess TelNet 52 – Tutorial - Common cases of configuration Avoid end of session Editing barcode reads Sending PDA name Connecting a serial scanner Macros

28 28 WireLess TelNet 52 – Tutorial - Common cases of configuration Options to configure wait timeouts and simulate a dialog How-to avoid end of session? PDA c onfiguration Explanation: The XS Timeout message indicates that the AS400 host is not responding to emulator requests in the PDA. If the PDA was turned off, probably the AS400 has closed the session. At wake-up time it makes a transaction, but the AS400 has closed the session and do not responds. PDA CONFIGURATION (5250 file) [TN52_EMULATION] XSTimeOut It is possible to modify the response wait time (in seconds) to adapt it to slow systems. You can either increase it or set it to zero to make it infinite. [TN52_TELNET] DoTcpAlive = YES The PDA can perform a periodical “ping” to the host and simulate a dialog to keep the session alive. On-line help

29 29 WireLess TelNet 52 – Tutorial - Common cases of configuration There are options to configure timeouts How-to avoid end of session? AS400 Configuration Explanation: AS400 system is configured by default to dialog with continuous connected peripherals. It polls them periodically, and close the connection if the device is not responding immediately (as a sleeping PDAs turned off). HOST CONFIGURATION (AS400 specific) Modify the AS400 timeouts as shown in the following PDF, to adapt it to use portable terminals with WiFi. AS400 Timeout Configuration AS400 Timeout Configuration

30 30 WireLess TelNet 52 – Tutorial - Common cases of configuration Editing barcode reads Configuration (generic file) [BC_EDIT_X] On= TIP! -> What can you do? Process following read length Process following barcode type Filter to suppress or keep: Ex: (NNYYYYNNYYYN) Y=keep the char. N=Suppress the char. Add characters: Ex: (****013****) *=Keep the char NNN=Adds a char. On-line help Barcode reads can be modified by an edit processing before sending them to input fields. How does it work? 1. Evaluate processing conditions. 2. Filter the reading to keep or suppress characters. 3. Add characters.

31 31 WireLess TelNet 52 – Tutorial - Common cases of configuration You can send the PDA name to AS400 host (workstation ID) Sending the PDA name CONFIGURATION (5250 file) [TN52_TELNET] TelOpEnvTerm=Yes This option allows to send information by the Telnet “Environment” option and to transmit the workstation ID. CONFIGURATION (generic file) [SESSION_0] DevName=MONDEVICE[0IP] Set here the PDA name. It is possible to add an index by IP address. Aide on-line

32 32 WireLess TelNet 52 – Tutorial - Common cases of configuration Connecting a serial scanner TIP! 3 powerful options WakeUp Restart connection at PDA wake-up. RestartBtn Shows ComKbd button. Close and reopen the COMX: port by a click (useful for Bluetooth ports). RestartKey Key to restart (close and open) the COMx: port. Configuration options to connect a serial scanner CONFIGURATION (generic file) Configuration option [SCANSERIAL] On= Remind to configure a suffix (terminator) in the serial scanner to perform the code transmission. On-line help

33 33 WireLess TelNet 52 – Tutorial - Common cases of configuration Simulate a keystroke sequence or texts, to automatically fill inputs Macros Example: To make easy a repetitive operations, it is possible to map a key to generate keystrokes or texts: * A text * FieldExit * Other text * F4 CONFIGURATION (5250 file) 1. Create a macro in a text file. 2. Define the key to launch the macro. 3.Download the file into the terminal. Example of a macro that sends text and function keys Macro map Macro configuration