1 AC 650 the NEW 650 series ac inverters beauty in simplicity...
Ratings from kW

2 AC 650 … simple to install … simple to set-up … simple to operate
no programming languages to learn easy to navigate menu ready-to-go from the box

3 AC 650 small in size… … long on features
built-in EMC compliant filters (up to 7.5kW, footprint >7.5kW) DIN rail or direct panel mounting (up to 7.5kW) pre-programmed applications

4 1 2 3 AC 650 3 2 1 3 new compact frames 230V 1ph .2kW .37kW .55kW
H W D (mm) 3 230V 1ph V 3ph .37kW 1.1kW kW 1.5kW kW 1.1kW 1.5kW 2.2kW 2 2 3 400V 3ph 3.0kW 4.0kW 5.5kW 7.5kW 1

5 AC 650 3 2 F E D C 1 above …7.5kW …up to 7.5kW All New Bookshelf
Frames 55(75)-90(110) KW 15(18.5)-22(30) KW 30(37)-45(55) KW 11(15) KW C D E F above …7.5kW V KW 3 2 1 230V KW V KW 230V KW V (Ratings In Brackets) = Quadratic “Fan” Torque …up to 7.5kW

6 AC 650 flexible inputs & outputs CONTROL POWER
ONE option provides two features - Remote-mount keypad together with P3 comms port CONTROL POWER volt-free relay contacts digital I/O 8 presets 2 programmable I/O motor thermistor AC line input analogue I/O 0 - 10V or 4-20mA input 1 programmable output for load or speed motor

7 AC 650 simple operator controls Backlit LCD display
Speed, Hz, or units Rotation local /remote START STOP Locally mounted & removable or Remote-mount option raise / lower speed program menu

8 AC 650 simple & easy ...for all your applications VT (Variable Torque)
CT (Constant Torque) material conveyors fans & blowers batch mixers centrifugal pumps

9 AC 650 simple tuning for your load type
Selectable v/f curves match your load requirement VT CONSTANT TORQUE VARIABLE TORQUE V f Vbase CT fbase

10 AC 650 simple programming Application selection parameter!
Directions on cover back Application selection parameter! Menu navigation Set-up parameters Diagnostics Fault codes

11 AC 650 simple application programming Applications 1 p basic speed
control 01 automatic/ manual 02 preset speeds 03 raise/ lower 04 PI control 05 STANDARD PARAMETERS Application 3, preset speeds p301 Preset 0 Application 5, PI p1 APPLICATION (1-5) : : p501 P gain p2 Max speed p3 Min Speed p308 Preset 7 p502 I gain p4 Accel time p5 Decel time p6 Motor rated current Application 2, automatic/manual - STANDARD PARAMETER LIST - with auto / manual control input selection p7 Base frequency Application 4, raise/lower p8 Jog setpoint p401 Ramp time p9 Stop mode p402 Max value p11 V/F shape p12 HVAC ratings p403 Min value p13 Fixed boost, (VF only) p404 Reset value p99 Password

12 AC 650 menu structure DIAG Diagnostics PAR Parameters SET Setup IN
APPLICATION (1-5) p2 Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS d1 Frequency (Hz) IN Inputs TRIP Disabled Trips (p1=1) d2 Speed setpoint (%) IP01 Digin 1 invert LOOP Anin2 input break d3 DC Link volts(v) IP02 Digin 2 invert T 3 Anin2 overload d4 Motor current (A) IP03 Digin 3 invert STLL Stall IP04 Digin 4 invert OT Motor over temp IP11 Anin 1 scale DB R Brake resistor IP12 Anin 1 offset DB S Brake switch IP13 Anin 1 type OP Op station IP21 Anin 2 scale IP22 Anin 2 offset SET Setup IP23 Anin 2 type ST01 Jog accel time APPLICATION PARAMETERS OUT Outputs ST02 Jog decel time p1 = 2 OP01 Anout select Application 2, automatic/manual ST03 Ramp type - STANDARD PARAMETER LIST - OP02 Anout scale ST04 S-ramp jerk OP03 Anout offset Application 3, presets p301 Preset 0 : p308 Preset 7 ST05 S-ramp continuous p1 = 3 OP04 Anout abs APPLICATIONPARAMETERS appear only when selected OP11 Digout 1 select ST11 Skip frequency 1 OP12 Digout 1 invert ST12 Skip freq band 1 OP21 Digout 2 select ST13 Skip frequency 2 Application 4, raise/lower p401 Ramp time p402 Max value p403 Min value p404 Reset value OP22 Digout 2 invert ST14 Skip freq band 2 p1 = 4 OP31 Relay select ST21 Auto restart attempts OP32 Relay invert ST22 Auto restart delay ST23 Auto restart triggers SERL Serial Comms ST24 Auto restart triggers+ p1 = 5 Application 5, PI p501 P gain p502 I gain SE01 Remote comms sel ST31 Dynamic brake enable SE02 Comms timeout ST32 DB resistance SE03 Address ST33 DB power SE04 Modbus baud rate SE05 Modbus parity ST34 DB over-rating

13 Application 1 : Basic Speed Control
Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 1 IDEAL FOR GENERAL PURPOSE APPLICATIONS, CONSTANT TORQUE AND VARIABLE TORQUE d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS P2 MAX SPEED Feedback 4-20mA P4 ACCEL TIME IP23 AIN2 TYPE V 1 0-5V mA mA IP13 AIN1 TYPE 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 MIN/MAX SPEED 1 2 3 4 5 6 7 8 9 10 REFERENCE SELECT P8 JOG SPD RAMP FWD/REV SPEED DEMAND Ref. P3 MIN SPEED OP01 ANOUT P5 DECEL TIME 0 NONE 1 DEMAND% 2 CURRENT% 3 PID ERROR% 4 RAISE/LOWER% P9 STOP MODE SEQUENCING LOGIC 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP21 DIGIO2 I FDBK START V/F SHAPING CURRENT LIMIT PWM CONTROL V FWD/REV V V JOG CT VT F F F STOP 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P6 I NOMINAL RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

14 Application 2 : Auto / Manual Control
Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 2 IDEAL FOR AUTOMATIC CONTROL APPLICATIONS WITH LIMIT SWITCHES OR PROXIMITY TRANSDUCERS d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS MIN/MAX SPEED P2 MAX SPEED P3 MIN SPEED P4 ACCEL TIME AUTO REF IP13 AIN1 TYPE REF SELECT 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 1 2 3 4 5 6 7 8 9 10 V 1 0-5V RAMP FWD/REV IP23 AIN2 TYPE SPEED DEMAND MAN. REF V 1 0-5V mA mA P5 DECEL TIME P9 STOP MODE P9 STOP MODE SEQUENCING LOGIC 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP21 DIGIO2 MAN. RUN I FDBK V/F SHAPING CURRENT LIMIT PWM CONTROL V AUTO RUN V V CT MAN./AUTO RUN SELECT VT F F F FWD / REV 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P6 I RATED RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

15 Application 3 : Preset Speeds
Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 3 IDEAL FOR APPLICATIONS WHERE MULTIPLE DISCRETE SPEED LEVELS ARE REQUIRED d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS (SCALABLE) IP300 PRESET 0 IP301 PRESET 1 IP302 PRESET 2 IP306 PRESET 6 IP305 PRESET 5 IP304 PRESET 4 IP303 PRESET 3 IP307 PRESET 7 AUTO REF MIN/MAX SPEED P2 MAX SPEED P3 MIN SPEED P4 ACCEL TIME 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 1 2 3 4 5 6 7 8 9 10 RAMP FWD/REV SPEED DEMAND SPEED DEMAND MAN. REF P5 DECEL TIME DIGIO2 DIGIO1 DIN2 PRESET 0V 24V 1 2 3 4 5 6 7 START/STOP I FDBK V/F SHAPING CURRENT LIMIT PWM CONTROL V PRESET IN V V CT VT PRESET IN F F F PRESET IN SEQUENCING LOGIC 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P9 STOP MODE P6 I NOMINAL RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

16 Application 4 : Raise/Lower
Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 4 IDEAL FOR APPLICATIONS WHICH REQUIRE SPEED CONTROL FROM MULTIPLE LOCATIONS d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS MIN/MAX SPEED P2 MAX SPEED P3 MIN SPEED P4 ACCEL TIME 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 1 2 3 4 5 6 7 8 9 10 RAISE / LOWER RAMP FWD/REV SPEED DEMAND SPEED DEMAND P5 DECEL TIME SEQUENCING LOGIC START/STOP P401 RAMP TIME I FDBK V/F SHAPING CURRENT LIMIT PWM CONTROL P402 MAX VALUE V RAISE V V P403 MIN VALUE CT VT LOWER P404 RESET VALUE F F F RESET 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P9 STOP MODE P6 I NOMINAL RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

17 Application 5 : PID Control
Max speed p3 Min Speed p4 Accel time p5 Decel time p6 Motor rated current p7 Base frequency p8 Jog setpoint p9 Stop mode p11 V/F shape p12 HVAC ratings p13 Fixed boost, (VF only) p99 Password STANDARD PARAMETERS P1 APPLICATION = 5 EASY TUNING FOR SETPOINT/ FEEDBACK CONTROL APPLICATIONS, REGULATING VOLUME OR PRESSURE, SUCH AS AIR HANDLING OR PUMPING d1 Frequency Hz d2 Speed Setpt % d3 DC Link Volts V d4 Motor I A DIAGNOSTICS P501 P GAIN P502 I GAIN P2 MAX SPEED P4 ACCEL TIME Feedback 4-20mA 0V AIN1 AIN2 +10V REF AOUT1 +24V DIN1 DIN2 DIGIO1 DIGIO2 PID CONTROL MIN/MAX SPEED 1 2 3 4 5 6 7 8 9 10 REFERENCE SELECT P8 JOG SPD RAMP FWD/REV SPEED DEMAND Ref. P3 MIN SPEED OP01 ANOUT 0 NONE 1 DEMAND% 2 CURRENT% 3 PID ERROR% 4 RAISE/LOWER% P5 DECEL TIME SEQUENCING LOGIC I FDBK START V/F SHAPING CURRENT LIMIT PWM CONTROL V FWD/REV V V JOG CT VT F F F STOP 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE P7 BASE FREQ P13 V BOOST P11 V/F SHAPE 60Hz base frequency P9 STOP MODE P6 I NOMINAL RL1A RL1B User Relay R 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP31 RELAY *BLUE is DEFAULT

18 AC 650 mount more drives per cabinet! VENTILATION
DIN rail mount on frames 1-3 No side ventilation allows for zero clearance between drives! VENTILATION

19 AC 650 the NEW 650 series ac inverters simple… smart… easy…

20 AC 650 the NEW 650 series ac inverters Thank you for your attention.