Leader in Ultrasonic Humidification. HUMIDIFIRSTS HISTORY Designing and prototyping of Ultrasonic Humidifiers begins in 1992 in Harrisburg, PA Designing.

Similar presentations


Presentation on theme: "Leader in Ultrasonic Humidification. HUMIDIFIRSTS HISTORY Designing and prototyping of Ultrasonic Humidifiers begins in 1992 in Harrisburg, PA Designing."— Presentation transcript:

1 Leader in Ultrasonic Humidification

2 HUMIDIFIRSTS HISTORY Designing and prototyping of Ultrasonic Humidifiers begins in 1992 in Harrisburg, PA Designing and prototyping of Ultrasonic Humidifiers begins in 1992 in Harrisburg, PA First patent applied for in 1993 First patent applied for in 1993 Shipped first equipment in 1994 to Boeing Co. Shipped first equipment in 1994 to Boeing Co. Second patent applied for in 1994 Second patent applied for in 1994 Manufacturing begins in Burlington, NC in 1994 Manufacturing begins in Burlington, NC in 1994 All manufacturing and R&D moved to Boynton Beach, FL in 2000 All manufacturing and R&D moved to Boynton Beach, FL in 2000

3 Data Room Humidification

4 ASHRAE Sets the Standards for the Recommended Data Room Operating Environment -Temperature -Humidity Reason? -To Reduce the Risk of ESD (Electrostatic Discharge) -ESD can damage electrical equipment -ESD can cause errors in operation & readings Sets the Standards for the Recommended Data Room Operating Environment -Temperature -Humidity Reason? -To Reduce the Risk of ESD (Electrostatic Discharge) -ESD can damage electrical equipment -ESD can cause errors in operation & readings

5 ASHRAE 2004 Recommended Data Room Operating Environment -Temperature = Low End at 68º F (20º C) High End at 77º F (25º C) -Humidity = Low End at 40% RH High End at 55% RH 2004 Recommended Data Room Operating Environment -Temperature = Low End at 68º F (20º C) High End at 77º F (25º C) -Humidity = Low End at 40% RH High End at 55% RH

6 2004 ASHRAE Psychrometric Chart

7 68F 40%RH 77F 55%RH

8 ASHRAE 2008 Recommended Data Room Operating Environment -Temperature = Low End at 64.4º F (18º C) not 68F High End at 80.6º F (27º C) not 77F -Humidity = Low End Dew Point 41.9º F DP (5.5º C) High End Dew Point 59º F DP (15º C) But < 60% RH 2008 Recommended Data Room Operating Environment -Temperature = Low End at 64.4º F (18º C) not 68F High End at 80.6º F (27º C) not 77F -Humidity = Low End Dew Point 41.9º F DP (5.5º C) High End Dew Point 59º F DP (15º C) But < 60% RH

9 Why Use Dew Point for Moisture Control? Studies show ESD is function of: -Absolute Humidity in Air, Not Relative Humidity of Air Studies show ESD is function of: -Absolute Humidity in Air, Not Relative Humidity of Air

10 2008 ASHRAE Psychrometric Chart High End Temperature is increased by 3.6º F Low End RH is decreased to < 30% RH at 80º F

11 64.4F to 80.6F at 41.9DP to 59DP 68F 77F

12 Result ? ENERGY SAVINGS! Data Rooms can operate at: - Higher Temperatures - Lower RH Levels This Encourages Economizer Cooling ENERGY SAVINGS! Data Rooms can operate at: - Higher Temperatures - Lower RH Levels This Encourages Economizer Cooling

13 How To Humidify Data Centers ? 1. Central Humidification -AHU -Ductwork 2. In-Room Humidification -In-CRAC -Wall Mount -Free-Standing 1. Central Humidification -AHU -Ductwork 2. In-Room Humidification -In-CRAC -Wall Mount -Free-Standing

14 Central Humidification AHU Mounted

15 Central Humidification Duct Mounted

16 Problems with Central Humidifiers: 1.Economizer Means Outside Air -Cold Air -Wetting Risk -Control Issues -Location of Humidifier: -Harder to Service -Difficult to Monitor 2.Direct Injection Steam- chemicals in air from boiler (needs heat exchangeradds cost) 3. If Humidifier Must be Outside Data Room, Corridor/Gallery is Preferable 1.Economizer Means Outside Air -Cold Air -Wetting Risk -Control Issues -Location of Humidifier: -Harder to Service -Difficult to Monitor 2.Direct Injection Steam- chemicals in air from boiler (needs heat exchangeradds cost) 3. If Humidifier Must be Outside Data Room, Corridor/Gallery is Preferable

17 Corridor/Gallery

18 In-Room Humidifiers In-CRAC Installation

19 CRAC Installation Photos

20 Problems with CRAC Humidifiers -Cold Air -Short Area for Evaporation

21 In-Room Humidifiers 1.Wall Mounted 2.Free Standing 1.Wall Mounted 2.Free Standing

22 Wall Mounted Mist-Pac Series

23

24 Free Standing Mist-Free Series

25

26 Benefits of In-Room Humidification 1.Direct Room Introduction of Moisture a) Higher Output Capacity 2.Better Control a) Sense Room Moisture without Concern of High-Limit Saturation b) More Accurate. Particularly with Individual Sensors 3.Easier to Service 4.Safety Overflow Control by Sensor and Drain Piping 1.Direct Room Introduction of Moisture a) Higher Output Capacity 2.Better Control a) Sense Room Moisture without Concern of High-Limit Saturation b) More Accurate. Particularly with Individual Sensors 3.Easier to Service 4.Safety Overflow Control by Sensor and Drain Piping

27 Mist-Free Series Drain and Safety Overflow Ready

28 Mist-Pac Series Drain and Safety Overflow Ready

29 HUMIDIFIRST QUALITY FIRST