1  Gitschotellei 138 - 2600 Berchem KBC 733-0106722-52  T +32 (0)3 235 02 81  F +32 (0)3 271 03 59 BTWBE 478.995.007 http://www.passiefhuisplatform.be @info@passiefhuisplatform.be Stefan Van Loon Technical consultant Commissioning: The first logic step for realizing high comfort buildings!

2 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen What is a “high comfort building”? Comfortable feeling independent the outside weather conditions Influencing parameters: –Surface temperatures –Air temperature –Air velocity –Air humidity –Air quality –Degree of activity –Clothing Necessity of a well-defined definition

3 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen BASE CONDITIONS –Heating demand ≤ 15 kWh/m².year –Air tightness n50-value ≤ 0,6 /h –Frequency of overheating ≤ 10% above 25°C SECONDARY CONDITIONS –U-values (walls, floors, roofs) ≤ 0,15W/m².K –U-values windows ≤ 0,80W/m².K –U-values glass ≤ 0,80W/m².K –Efficiency of heat exchanger ventilation ≥ 75% –Efficiency fans (SPF) ≤ 0,45W/(m³/h) –Thermal bridge free construction Ψ ≤ 0,01W/m.K Passive house concept is currently the only well-defined standard! Build-in ≤ 0,85W/m².K

4 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen How’s commissioning done?

5 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen Commissioning CHECKLIST: REQUEST PASSIVEHOUSE CERTIFICATE DESCRIPTION AVAILABLE Softcopy (=excel-file) of the PHPP-calculation (version 2003 or higher) Sheet 'Results' of the PHPP-calculation signed by PHPP-calculator Project layouts with orientation of the building buildings close to the building site (implantation and profilel) (only when sheet 'shadow' is filled in) important trees and other obstructions (only when sheet 'shadow' is filled in) possible field-profiles for shading by obstruction of the horizon (only when sheet 'shadow' is filled in) floorplan of every floor All façade-sides Minimum 2 cuts where every different height level is visible. In addition a clear representation of all different used wall-, floor- and roofcomposition. All drawings need to carry clear dimensions necessarry for a fast software-input

6 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen Commissioning CHECKLIST: REQUEST PASSIVEHOUSE CERTIFICATE DESCRIPTION AVAILABLE Minimum 4 photo's of the finished buildings (minimum 1 photo perpendicular on every façade) Detailed drawings of standard wall construction junction foundation - wall construction (in- and outside walls) junction wall - roof construction junction in between floors - wall construction junction windows/doors (bottom, top, sides) - wall construction junction corners (in- and outside corners) of wall- and roofconstructions special junctions (housetop, roofwindows, …) Technical chart/certificate of glazing according to EN673, EN410 + invoices Technical chart/certificate of windows according EN10077 + invoices Technical chart/certificate of doors according to EN10077 + invoices Belgian of european certificate of all used insulationmaterials (www.atg.be, www.butgb.be, www.eota.be) + invoices

7 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen Commissioning CHECKLIST: REQUEST PASSIVEHOUSE CERTIFICATE DESCRIPTION AVAILAB LE Ventilation Technical chart with efficiencyrate according to PHI (www.passiv.de) or according to EN308 + invoice ventilation-unit indication on the plan of suction- and blow off-opening to outside location indication of the ventilation installation indication earth to air heat exchanger (EAHX) + characteristics (lentgh, diameter, depth) + invoice Testreport/certificate air tightness of the building shell in accordence with EN 13829, as well as in overpressure and underpressure Calculation of thermal bridges when there's less then 5cm insulation, with a maximum lamda-value of 0,05W/mK, or equivalent, located and this in all directions EPB-calculation + signed EPB-report Possibly other proofs necessary at dataimport in PHPP Additional for non-residential buildings as-built plans of the complete installation As-built plans of HVAC-installations for multi-family houses, schools and offices As-built plans and studies of lighting in offices and schools; Studies for special buildings

8 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen Commissioning Fiscal benefits Lower house owner taxes (KI) Contributions (Some regions, network administrators)

9 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen Importance of commissioning

10 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen Future Commissioning plans Ventilation –Development of special checklist Heating

11 Passiefhuis-Platform vzw De REFLEX voor energiebewust bouwen Commissioning