VT 2000 Default Timers The VT 2000 has 61 Default timers. 50 timers control equipment start/stop times. The rest control safeties, ultrasonics, etc. The.

Similar presentations


Presentation on theme: "VT 2000 Default Timers The VT 2000 has 61 Default timers. 50 timers control equipment start/stop times. The rest control safeties, ultrasonics, etc. The."— Presentation transcript:

1 VT 2000 Default Timers The VT 2000 has 61 Default timers. 50 timers control equipment start/stop times. The rest control safeties, ultrasonics, etc. The key to proper timer adjustment is to first complete the 102 steps in the “Installation Start- Up & Test Procedure” document.

2 Start Stop Timer Setup Measure distance from the measuring photoeye to the equipment in question. Divide this distance in inches by 8 to get the approximate start count time.

3 VT 2000 Default Timers All Start Stop Timers Must Be Individually Set. D897 Top Brush Measured Distance. D898 Ultrasonic Measured Distance. D903 #1 Wraps Stop: Should Be Set To 8 After Rear Of Car. D905 #2 Wraps Stop: Should Be Set To 8 After Rear Of Car. D906, D907, D908: New Chemical Arch Registers. Simply Select 1 Of 8 Chemicals To Be Applied.


Download ppt "VT 2000 Default Timers The VT 2000 has 61 Default timers. 50 timers control equipment start/stop times. The rest control safeties, ultrasonics, etc. The."