Www.anton-paar.com Product Presentation C-PTD 180/AIR/QC Air-cooled Peltier Temperature System 28.02.2013.

Similar presentations


Presentation on theme: "Www.anton-paar.com Product Presentation C-PTD 180/AIR/QC Air-cooled Peltier Temperature System 28.02.2013."— Presentation transcript:

1 Product Presentation C-PTD 180/AIR/QC Air-cooled Peltier Temperature System

2 Content ▸ Pictures ▸ Features and Benefits ▸ Specification ▸ Performance ▸ Measurements ▸ Special Features ▸ Article Number and Price ▸ Configuration Example ▸ Applications and Markets ▸ Competition ▸ Summary

3 Pictures P-CTD 180/AIR/QC

4 Features and Benefits C-PTD 180/AIR/QC ▸ Temperature RangeComplete range: 0 °C to 180 °C ▸ Measuring SystemsConcentric Cylinder Measuring Systems Disposable Measuring Systems Stirrers and Spindles ▸ Air-cooled Peltier systemNo counter cooling necessary ▸ Typical MeasurementsIsothermal temperature tests Temperature ramps Temperature swing tests

5 C-PTD 180/AIR/QC - Specification Temperature range0 °C to 180 °C Measuring systemsStandard systems, DG42 BeakerStandard beaker, max. CC39 or DG42 GeneralGood cleanability Radiation system for counter cooling Surrounding conditions Temperature range5 °C to 35 °C Relative humidity, not condensing< 80 % AltitudeUp to 2000 m PollutionPollution degree 2 according to EN SurroundingLaboratory, indoor us only Supply Supply voltage85 to 265 V Frequency50 … 60 Hz OvervoltageOvervoltage category II according to EN

6 Technical Specification – Heating Rates Comparison Peltier / Liquid Temperature Control Heating rate (Peltier): 8.0 °C/min Heating rate (Liquid): 5.0 °C/min

7 Technical Specification – Cooling Rates Comparison Peltier / Liquid Temperature Control Cooling rate (Peltier): 4.0 °C/min Cooling rate (Liquid): 0.5 °C/min

8 Examples - Heating Stable Conditions after approx. 15 min

9 Examples - Cooling Stable Conditions after approx. 15 min

10 Special Features Wide temperature range: 0 °C to 180 °C Air cooled Peltier temperature system Rapid changes in temperature No external controller necessary No counter cooling by an external circulator Easy to install Space saving design Noise reduced

11 Article Number Item-no C-PTD 180/AIR/QC Peltier Temp. Control System Temp. range: 0 to 180 °C

12 Standard Configuration Basic Instrument RheolabQC C-PTD 180/AIR/QC Disposable Measuring System CC39/D/QC-LTD Disposable Measuring System CC27/D/QC-LTD Option: 18385Software Rheoplus

13 Applications & Markets Coatings:Flow Curve, Yield Point, 3ITT (Thixotropy) Food:Flow Curve, Yield Point, Temperature Test, 3ITT (Thixotropy) Building Materials:Flow Curve, Yield Point, 3ITT (Thixotropy)

14 Applications & Markets Adhesives:Flow Curve, 3ITT (Thixotropy), Temperature Test Cosmetics:Flow Curve, Yield Point, Temperature Swing Test Pharma:Flow Curve, Yield Point, Temperature Swing Test Soft Gels:Yield Point, 3ITT (Thixotropy) Lubricants, Oils:Flow Curve, Temperature Test Asphalt:Flow Curve, Temperature Test

15 Summary C-PTD 180/AIR/QC is the new Peltier temperature system for the RheolabQC with: ▸ Wide temperature range: 0 °C to 180 °C ▸ Air cooled Peltier temperature system ▸ Cheaper configuration compared with the liquid temp. control systems ▸ Compact design, no counter cooling by an external circulator ▸ Easy handling ▸ Small footprint ▸ Noise reduced compared to a fluid circulator ▸ Low power consumption ▸ Fast and accurate temperature setting ▸ no thermal fluids/oil necessary ▸ Firmware V1.26 for the RheolabQC required